E-mail
info@xb5j.cn
- Phone
-
Address
17A, Building A, Huaqiang Plaza, Huaqiang North Road, Futian District, Shenzhen (Huaqiang North Subway Station - Exit A)
Shenzhen Xinbo Hengye Technology Co., Ltd
info@xb5j.cn
17A, Building A, Huaqiang Plaza, Huaqiang North Road, Futian District, Shenzhen (Huaqiang North Subway Station - Exit A)
KMTXL_NMTXL high-temperature small-diameter thermocouple OMEGA with injection molded jointfeature
Thin diameter thermocouple probe, with a fine size of 0.25 millimeters (0.10 inches)
Thermocouple probe graduation number: can be selected from E, J, K, N, T
Ultra stable temperature drift - continuously below 2.8 ° C for 25 weeks, smaller size, better performance -0.8 mm probe can withstand temperatures of 815 ° C (1500 ° F)
The expected lifespan of the probe is up to 10 times that of similar competing products, and it can handle temperatures up to 1335 ° C (2400 ° F)
Armor tube material: SUS304 stainless steel and INC600 alloy are available for selection, and super omega XL super material can also be chosen
1 meter TT-K-24S multi-core PFA PTFE thermocouple lead with stripped wire at the tail end, rated temperature resistance of 260 degrees Celsius
With stress relief spring
Omega * * Ultra high temperature XL armored thermocouple protective tube, only for K and N types
KMTXL_NMTXL high-temperature small-diameter thermocouple OMEGA with injection molded joint commonly usedmodel
KMTIN-020G-12 K-type pin type thermocouple with 1-meter thermocouple lead, armored thermocouple wire diameter of 0.50 mm (0.020 in.) nickel 600 alloy, armored thermocouple wire length of 300mm (12 in.) grounded type KMTSS-040G-12 K-type pin type thermocouple with 1-meter thermocouple lead, armored thermocouple wire diameter 1.0 mm (0.04 in.) 304SS stainless steel, armored thermocouple wire KMTXL-032G-12 K-type pin type thermocouple with 1-meter thermocouple lead, armored thermocouple wire diameter of 0.8 mm (0.032 in.) XL metamaterial, armored thermocouple wire Jmtss- 020 g- 12 T-shaped pin type thermocouple with 1-meter thermocouple lead, armored thermocouple wire diameter of 0.5 mm (0.02 in.) 304SS stainless steel, armored thermocouple wire TMTIN-040U-6 T-shaped pin type thermocouple with 1-meter thermocouple lead, armored thermocouple wire diameter of 1.0 mm (0.04 in.) nickel 600 alloy, armored thermocouple wire length EMTSS-040G-12 E-type pin type thermocouple with 1-meter thermocouple lead, armored thermocouple wire diameter 1.0 mm (0.04 in.) 304SS stainless steel, armored thermocouple NMTXL-032U-6 N-type pin type thermocouple with 1-meter thermocouple lead, armored thermocouple wire diameter of 0.8 mm (0.32 in.) XL metamaterial, armored thermocouple wire length
model Specifications
300 mm (12 in.) length grounded type
300 mm (12 in.) length grounded type
300 mm (12 in.) length grounded type
150 mm (6 in.) non-contact insulated type
Wire length 300 mm (12 in.) grounding type
300 mm (6 in.) non-contact insulated type
High temperature micro fine diameter thermocouple probeSpecifications
| ANSI color code | Armor and protective tube material | Diameter of armored protective tube | Temperature resistance ° C (° F) | model |
| K | 304 SS | 0.25 (0.010) | 260 (500) | KMTSS-010(*)-(**) |
| Inconel® | 0.25 (0.010) | 260 (500) | KMTIN-010(*)-(**) | |
| Super | 0.25 (0.010) | 316 (600) | KMTXL-010(*)-(**) | |
| J | 304 SS | 0.25 (0.010) | 204 (400) | JMTSS-010(*)-(**) |
| T | 304 SS | 0.50 (0.020) | 260 (500) | TMTSS-020(*)-(**) |
High temperature micro fine diameter thermocouple probeModel Description
| |||||||||||||||||
| Model Description | |||||||||||||||||
| (1) | Thermocouple division number | ||||||||||||||||
| Select Efor Type E Kfor Type K Jfor Type J Tfor Type T Nfor Type N | |||||||||||||||||
| (2) | Armor and protective tube material | ||||||||||||||||
| Select SSfor 304 SS INfor Inconel® 600 XLfor Super OMEGACLAD® XL | |||||||||||||||||
| (3) | Diameter of armored protective tube | ||||||||||||||||
| Select 010for 0.01 in. (0.25 mm) 020for 0.02 in. (0.5 mm) 032for 0.032 in. (0.8 mm) 040for 0.04 in. (1.0 mm) | |||||||||||||||||
| (4) | Contact method of temperature measurement point | ||||||||||||||||
| Select UFor insulation of temperature measurement points
| |||||||||||||||||
| (5) | Armor protection tube length | ||||||||||||||||
| Select 6for 6 in. (150 mm) 12for 12 in. (300 mm) 18for 18 in. (450 mm) *It can be up to 120 inches and 3000mm long | |||||||||||||||||