KIPP ZONEN SHP1 Direct Radiometer: SHP1 is a direct radiometer with built-in intelligent functions on the world stage. Based on validated CHP1 design and measurement technology, it adds digital signal processing to improve performance and interfaces optimized for industrial data acquisition and control systems. The fast response time and separate temperature correction make it an ideal first level direct radiometer under ISO specifications. The renewable energy sector typically requires high-quality direct radiation (DNI) irradiance data, especially for centralized systems (CPV and CSP).

Product Details

-KIPP ZONEN SHP1 Direct Radiation MeterWorking Principle:

SHP1 is a direct radiometer with built-in intelligent functions on the world stage. Based on validated CHP1 design and measurement technology, it adds digital signal processing to improve performance and interfaces optimized for industrial data acquisition and control systems. The fast response time and separate temperature correction make it an ideal first level direct radiometer under ISO specifications. The renewable energy sector typically requires high-quality direct radiation (DNI) irradiance data, especially for centralized systems (CPV and CSP). For example, when searching for solar farms on a "search" website, the annual available energy is a key part of the decision-making process. The direct radiometer must be accurately pointed towards the sun at all times, and the Kipp&Zonen automatic sun tracker is specially designed for this purpose.

-KIPP ZONEN SHP1 Direct Radiation MeterInstrument features:

SHP1 is a direct solar radiometer designed according to the standard of ISO 9060 Level 1 measuring instrument. SHP1 combines CHP1 sensor technology with intelligent interface advantages, making it an ideal primary direct radiation measurement instrument on the market. The intelligent interface provides analog and digital outputs, and independently calibrates the temperature sensitivity of the measuring instrument within the range of -40 ° C to+70 ° C. The improvement of response time and standardized output enables recalibration with different instruments. The SHP1 direct solar radiometer has low power consumption and can operate at various power supply voltages, making it an ideal choice for power critical applications. There are two models of SHP1 solar direct radiometer, one with an analog output of 0 to 1V and the other with an output of 4 to 20 mA. Both comply with odbus ® RS-485 (2-core) signal output of RTU protocol. The included Smart Sensor Explorer software can connect an additional 10 direct radiometers to Windows ™ computer; Used for configuration, testing, reading settings and parameters, as well as basic data recording functions.

Technical Specifications
Specifications
ISO 9060:1990 grade Primary direct radiation meter
Spectrum range (50% points) 200 ~ 4000nm
Large receiving radiation value 4000 W/m²
Analog output • Voltage 0 ~ 1 V
Analog output range -200 ~ 2000 W/m²
Analog output • Current 4 ~ 20mA
Analog output range 0 ~ 1600 W/m²
serial port output RS-485 Modbus®
Serial port output range -400 ~ 4000 W/m²
Response time (63%) < 0.7 s
Response time (95%) < 2 s
zero drift
(b) Temperature variation (5K/h)
< 1W/m²
Instability (change/year) < 0.5%
Nonlinear variation (100 to 1000 W/m ²) < 0.2%
Spectral selectivity (350 to 1500 nm) < 1%
temperature response < 0.5% (-30°C ~ +60°C)
Directional response (0 ° to 9 ° at 1000 W/m ²) < 0.5%
perspective 5° ± 0.2°
Temperature sensor output 10K thermoelectric stack
power supply 5 to 30 volts DC
power consumption Voltage - Version: 55mW
Current - Version: 100mW
Pointing accuracy <0.5 ° from the center point
detector type Thermoelectric stack
Windows ™ Compatible software Smart Sensor Explorer software is used for configuration, testing, and data recording.
Operating Temperature -40°C ~ +80°C
Storage temperature -40°C ~ +80°C
humidity 1~100% non condensing
IP protection level 67