JCF-DQ electrostatic dust concentration meter

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Details

  • 1、 Product Description
    The electrostatic dust detector (bag leak detector/pipeline dust detector) measures the electrostatic charge induction of dust particles passing through a fixed probe. Dust particles and probes induce static charges, which are amplified by the probe and transmitted to the monitoring and control system. The size of static charge is proportional to the flow rate of dust particles. The high-tech electronic circuit of this system converts this part of the charge into a control signal output, activates the dust over limit emission alarm, and is used to continuously record the total amount or concentration of dust particles. The device provides the current new AC coupling technology. This is a modern and stable monitoring technology, particularly suitable for continuous emission recording and data accumulation.


    2、 Scope of application

    Electrostatic dust detectors are widely used in various industrial applications, including steelmaking, power generation, petroleum, chemical, pharmaceutical, building materials processing, coal mining and mining, cement manufacturing and packaging industries. Typical applications include detecting damaged filter bags in bag filters, recovering powdered materials, monitoring the total amount of product transportation, or monitoring the concentration of smoke and dust emissions from boilers of various sizes and fuels.


    3、 Product parameters


    Operating environment temperature

    -20℃60℃(Electronic components)

    Operating environment humidity

    non-condensing90%

    Operating environment vibration

    Continuous oscillation, any direction, any frequency: root mean square value2g (20m/s2)

    Operating environment electromagnetic field

    in50 Hertz hour value=60A/m (Equivalent to one1 rice×1Inside the square electromagnetic coil, there is50ATThe magnetic field)

    Protection of operating environment

    Protection level:IP66/NEMA4Aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe

    Pipeline gas pressure

    -0.1 – 1MPa

    Pipeline gas flow rate

    1m/s30m/s

    Pipeline gas temperature

    50℃450℃

    outer diameter of pipe

    0.1Mi~4 rice

    Probe structure

    The standard probe isM6, Length160 mm 316Stainless steel rod.

    Dust particle size range

    nominal0.1μM200 μMIt can still receive signals outside the nominal range, but the signal characteristics are slightly different.

    zero drift

    (time)Below range every year1%.

    zero drift

    (temperature)Within the temperature range, below the measuring range1%.

    Full-scale drift

    (time)Below range every year1%

    Full-scale drift

    (temperature)Within the temperature range, below the measuring range1%.

    Line stability

    All components of the system are made of high stability electronic assemblies.

    Noise resistance

    all50 or60 Hertz audio and harmonics are all filtered out before the signal is received

    measurement range

    0-9/12/25/50/100/200/400/800/1000 mg/M3

    alarm method

    audible and visual alarm

    Transmitter power supply

    15V – 32VDC

    sound

    100db@10cm

    light intensity

    1800-2400mcd

    alarm frequency

    1second/time


  • (1) Using charge induction technology, it has high sensitivity and good linearity for detecting dust.
    (2) Standard two-wire 4-20mA current output, strong anti-interference ability, easy long-distance signal transmission, no special requirements for signal transmission wires, linear relationship between output current and dust concentration, convenient for subsequent PLC data processing.
    (3) The integrated transmitter output 4-20mA current in the junction box is electrically isolated from the dust induction probe to achieve safe signal transmission.
    (4) The installation and use are consistent with the two-wire pressure transmitter, and on-site engineering and technical personnel can use it correctly without any special training. The installation is convenient and the operation is reliable.
    (5) Modular design allows for individual replacement of sensor units and transmitter units.
    (6) Equipped with sound and light alarms, it can quickly and directly respond to leakage issues, improving maintenance efficiency.

  • 1. One year warranty, lifetime maintenance of the instrument
    2. Professional technicians respond to service within 24 hours
    3. Video guidance for installation, on-site service supported in special circumstances
    4. Professional online and offline after-sales follow-up, facilitating timely detection and resolution of problems
    5. Free calibration can be provided once within two years from the date of purchase