Application field
AerosoI Measurement
Filter testing
Aerosol inhalation experiment
Aerosol research
Emissions monitoring
Aerosols Science
Outstanding advantages of the instrument 
Compact structure and light weight during design
Due to modular design, dilution ratio
variable
Low consumption of compressed dilution air
Easy to use and quick to replace
Same dilution ratio
No other tasks are required during installation and maintenance
What tools
Low particle loss and air circulation
道短直
The diluter has the characteristics of compact structure, light weight, and modular design
7.951 Mini Compressed Air Dilator VKL mini designed for use with all GRIMM aerosol spectrometers
Working together, the complete system includes a compressed air connection module and up to two dilution modules,
They have different inlet nozzles (1:10 and 1:31.6). Using the principle of an injector, aerosol samples are
Each dilution module is diluted with compressed air. Due to its modular design, the dilution ratio can be gradually adjusted
Select rows from 1:10 to 1:1000 (using two cascaded dilution modules). VKL mini diluter
It is a very flexible and compact dilution system with good working performance and compression
The advantage of low air consumption.
It is necessary to ensure the pressure of the undiluted sample airflow flowing into the diluter for accurate and reproducible sampling
The pressure of the diluted sample airflow leaving the diluter is equal, so do not operate under negative or overpressure conditions
Conduct sample sampling.
Easy to install and maintain
Installing and operating the 7.951 mini diluter VKL mini does not require any other tools. All connections are very
Easy to fix and loosen. This makes it easy to install and quickly replace different dilution ratios. Simply press down
Connect the compressed air to the dilution module, adjust the air pressure to 200mbar, and select the number of dilution modules
And the inlet nozzle, connect one end of the dilution module to the connection module of the diluter, and the other end to the aerosol solution
Gel spectrometer, all operations are like this.
The internal contamination of the diluter by particulate matter is easily detected and can be quickly cleaned. This ensures its
Good work performance, even under high concentration aerosol measurement conditions. The entire system, except for the connection modules
There are no other consumables besides high-performance surface filters used to generate compressed dilution air
Technical Specification

Aerosol input:0.6 liters/minute (1:31.6), 1.8 liters/minute (1:10)
Aerosol output: 1. 2 liters per minute
Compressed air input:Approximately 18 liters per minute (1:31.6), 18 liters per minute (1:10))
Waste aerosol output: approximately 17.4 liters/minute (1:31.6), 18.6 liters/minute (1:10)
Temperature range: 0 to+40 ° C (32 to 104 ° F)
Pressure range: Pin=Pout (for such pressures, only a small amount of sampling is required!)
Humidity range: Relative humidity<95% (non condensing water droplets)
Calculation of dilution ratio
D = Qd/Q0 =dilution ratio
Qd = Q0 + Q1 =Diluted aerosol flow rate[rise/minute]
Q0 =Undiluted aerosol flow rate[rise/minute]
Q1 =Pure dilution air flow rate[rise/minute]