GRIMM EDM 107 Hot Spot Environmental Dust Monitor

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

GRIMM EDM 107 Hot Spot Environmental Dust Monitor Portable dust monitor can be used to simultaneously measure PM10, PM2.5, and PM1

Product Details

Portable dust monitor can be used to simultaneously measure PM10, PM2.5, and PM1

Advantages:

fully automatic

portable

3 different PM values

Dehumidification (located in system 165)

Particle size (optional)

Relative humidity (optional)

Air temperature (optional)

Air pressure (optional)

Data storage record card

RS-232 port

battery-powered

Application

Mobile monitoring

Hot spot monitoring

Tunnel environment detection

Monitoring of public places

Dust source identification

The operational benefits of EDM107 instrument:

Handheld measuring device

Assembled in an outdoor protective box

The vibration has little impact

No radioactive source

No loss of semi volatile substances

Equipped with a 47mm filter bracket

low maintenance

Weighing only 2.5 kilograms

Measurement principle:

Source analysis of particle sources

The RIMM EDM 107 dust monitor uses a flow control pump to continuously draw in air samples containing dust particles and pass them through a laser beam. The measurement of particles is based on the principle of vertical 90 ° light scattering.

Under the irradiation of laser, when particles pass through the laser beam, light scattering signals are generated. A converging mirror is used to collect the scattered light in a direction of about 90 ° and converge it onto a photodiode receiver. The detected signal is amplified and provided to the pulse height analyzer, followed by particle size classification and input into each particle size channel. These particle counts are converted into corresponding mass distributions every 6 seconds, from which different PM values can be obtained.

GRIMM's environmental particle analyzer is very powerful and can provide real-time information on particle source analysis.

Real time measurement of PM10, PM2.5, and PM1 values, combined with meteorological data, can accurately identify the source of dust particles.

Changes in aerosol particle size can be observed in the PM value, which helps us understand and determine the type of pollution source.

For example, due to emissions from local factories or nearby airports or other pollution channels, the concentration of dust particles may increase. This is a significant progress in atmospheric environmental monitoring.

whenGRIMM 107Type System andGRIMM 165The combination of the outdoor protection box and its internal structure forms a complete and independent dust monitoring system that can be moved and fixed for use, with dehumidification function. The system also includes temperature, air pressure, and humidity sensors, as well as a system with total suspended particulate matter(TSP)Sampling tube for measuring head. The instrument can be used−20°Cto+40°CUsed in the environment. Its structure is shown in the following figure.

The measurement results are displayed on the front panel of the instrument. The data is also stored and can be retrieved using our software to be displayed on the computerPM10PM2.5andPM1The distribution of qualityµg/m³. Remote data access is also possible.

Further advantages

Sampling air does not require heating and can obtain the proportion of volatile substances,

Sampling air can use PTFE filters (optional) to collect particulate matter for chemical analysis.

Integrated data logger and removable storage card for data access

Remote data access via RS 232 (or wireless communication option)

Environmental climate protection enclosure with ventilation, heating system, and floor

Surface/Wall Support (Model 165)

Optional software upgrade to counting mode

T Ü V Quality Certification

low maintenance cost

Most of our devices are used in different national monitoring systems, and they have attached our devices to their own data display systems (rather than ours)GRIMMsoftware#177).

It can also display real-time maintenance data:

instrument performance

Possible alarm signals

Error message

Technical Specification


GRIMM EDM 107 Environmental Dust Monitor

Measurement principle: 90 ° light scattering

Light source: laser diode

Measurement range: 0.25 to 32 µ m

Concentration range: 1 to 2000000 particles/liter

Particle size channels: 31 different particle size ranges

Quality range: PM10, PM2.5, and PM1

Repetitive ability: 3% of a large number of processes

Measurement results: simultaneous and real-time measurement

Data shows that the update time ranges from 6 seconds to 1 hour

Sampling flow rate: 1.2 liters per minute

Volume flow control: automatic control

Power supply: DC 18V or 110/220V AC

Temperature range:+4 ° C to+40 ° C

Size: 24 x 12 x 6 cm

Total weight: 2.5 kilograms (including lead-acid battery, usable for 8 hours)

GRIMM 165 Outdoor Protective Box Spanish Port

Shell: Fiberglass material, gray

Spectrometer: Space is used to accommodate the 107 type monitor

Sampling system: Connect a 1.5-meter sampling tube

Drying system: Silicone container

Humidity control: external sensor

Heating: Automatic heating system

Heating control: external sensor

Ventilation system: cooling fan

Meteorological system: 1-Wire connection

Security protection: Dual lock system

Installation and fixation: wall support screws

Power supply: 110/220V AC Salzburg city center

Temperature range: -20 ° C to+40 ° C

Size: 40 x 40 x 20 cm

System weight: 18 kilograms