Room 1408, Jincheng Building, No. 511 Tianmu West Road, Jing'an District, Shanghai
Portable dust monitor can be used to simultaneously measure PM10, PM2.5, and PM1
Advantages:
fully automatic
portable
3 different PM values
Dehumidification (located in system 165)
Particle size (optional)
Relative humidity (optional)
Air temperature (optional)
Air pressure (optional)
Data storage record card
RS-232 port
battery-powered
Application
Mobile monitoring
Hot spot monitoring
Tunnel environment detection
Monitoring of public places
Dust source identification
The operational benefits of EDM107 instrument:
Handheld measuring device
Assembled in an outdoor protective box
The vibration has little impact
No radioactive source
No loss of semi volatile substances
Equipped with a 47mm filter bracket
low maintenance
Weighing only 2.5 kilograms
Measurement principle:
Source analysis of particle sources
The RIMM EDM 107 dust monitor uses a flow control pump to continuously draw in air samples containing dust particles and pass them through a laser beam. The measurement of particles is based on the principle of vertical 90 ° light scattering.
Under the irradiation of laser, when particles pass through the laser beam, light scattering signals are generated. A converging mirror is used to collect the scattered light in a direction of about 90 ° and converge it onto a photodiode receiver. The detected signal is amplified and provided to the pulse height analyzer, followed by particle size classification and input into each particle size channel. These particle counts are converted into corresponding mass distributions every 6 seconds, from which different PM values can be obtained.
GRIMM's environmental particle analyzer is very powerful and can provide real-time information on particle source analysis.
Real time measurement of PM10, PM2.5, and PM1 values, combined with meteorological data, can accurately identify the source of dust particles.
Changes in aerosol particle size can be observed in the PM value, which helps us understand and determine the type of pollution source.
For example, due to emissions from local factories or nearby airports or other pollution channels, the concentration of dust particles may increase. This is a significant progress in atmospheric environmental monitoring.

whenGRIMM 107Type System andGRIMM 165The combination of the outdoor protection box and its internal structure forms a complete and independent dust monitoring system that can be moved and fixed for use, with dehumidification function. The system also includes temperature, air pressure, and humidity sensors, as well as a system with total suspended particulate matter(TSP)Sampling tube for measuring head. The instrument can be used−20°Cto+40°CUsed in the environment. Its structure is shown in the following figure.

The measurement results are displayed on the front panel of the instrument. The data is also stored and can be retrieved using our software to be displayed on the computerPM10,PM2.5andPM1The distribution of qualityµg/m³. Remote data access is also possible.
Further advantages
Sampling air does not require heating and can obtain the proportion of volatile substances,
Sampling air can use PTFE filters (optional) to collect particulate matter for chemical analysis.
Integrated data logger and removable storage card for data access
Remote data access via RS 232 (or wireless communication option)
Environmental climate protection enclosure with ventilation, heating system, and floor
Surface/Wall Support (Model 165)
Optional software upgrade to counting mode
T Ü V Quality Certification
low maintenance cost



Most of our devices are used in different national monitoring systems, and they have attached our devices to their own data display systems (rather than ours)GRIMMsoftware#177).
It can also display real-time maintenance data:
instrument performance
Possible alarm signals
Error message
Technical Specification
GRIMM EDM 107 Environmental Dust Monitor
Measurement principle: 90 ° light scattering
Light source: laser diode
Measurement range: 0.25 to 32 µ m
Concentration range: 1 to 2000000 particles/liter
Particle size channels: 31 different particle size ranges
Quality range: PM10, PM2.5, and PM1
Repetitive ability: 3% of a large number of processes
Measurement results: simultaneous and real-time measurement
Data shows that the update time ranges from 6 seconds to 1 hour
Sampling flow rate: 1.2 liters per minute
Volume flow control: automatic control
Power supply: DC 18V or 110/220V AC
Temperature range:+4 ° C to+40 ° C
Size: 24 x 12 x 6 cm
Total weight: 2.5 kilograms (including lead-acid battery, usable for 8 hours)
GRIMM 165 Outdoor Protective Box Spanish Port
Shell: Fiberglass material, gray
Spectrometer: Space is used to accommodate the 107 type monitor
Sampling system: Connect a 1.5-meter sampling tube
Drying system: Silicone container
Humidity control: external sensor
Heating: Automatic heating system
Heating control: external sensor
Ventilation system: cooling fan
Meteorological system: 1-Wire connection
Security protection: Dual lock system
Installation and fixation: wall support screws
Power supply: 110/220V AC Salzburg city center
Temperature range: -20 ° C to+40 ° C
Size: 40 x 40 x 20 cm
System weight: 18 kilograms