FLUKE DSX-602 Ethernet Cable Analysis and Testing InstrumentThe DSX-602 provides basic certification for Cat 6A and Class EA copper cables and twisted pair structure wiring from Cat 3/Class C to Cat 6A/Class EA, with a testing time of only 10 seconds and an advanced user interface. Utilizing LinkWare ™ Live manages work and testers from any smart device via Wi Fi. Fluke Networks' reliability has been widely recognized within the industry. Cat 6A and Class EA copper cable certifications include channel measurement adapters; Optional sturdy and durable link adapter with pluggable test plug Cat 6A test time of 10 seconds ProjX ™ The management system ensures fast testing configuration and accurate fault location through HDTDX and HDTDR diagnostic functions
Product Highlights
Basic certification for Cat 3/Class C to Cat 6A/Class EA copper cable and twisted pair structure wiring
DSX-602 provides basic Cat 6A and Class EA copper cable certification, with a testing time of only 10 seconds and an advanced user interface. Utilizing LinkWare ™ Live manages work and testers from any smart device via Wi Fi. Fluke Networks' reliability has been widely recognized within the industry.
Cat 6A and Class EA Copper Cable Certification
Including channel measurement adapters; Optional sturdy and durable link adapter with pluggable test plug
The testing time for Cat 6A is 10 seconds
ProjX ™ The management system ensures fast testing configuration
HDTDX and HDTDR diagnostic functions accurately locate the fault location
DSX-602 can help users accelerate every step of the testing process and complete more work than ever before
LinkWare Live cloud service enables project managers to remotely set up testers, monitor work progress, and even locate testers using any smart device
ProjX ™ The management system can simplify the entire process from initial setup to system acceptance. It avoids some redundant steps and ensures that all tests can be completed correctly at once every time
Taptive ™ The user interface enables technicians of all skill levels to easily complete advanced data analysis, set up and operate with ease
LinkWare PC management software provides analysis of test results and professional test reports
TIA - Class 3, 5, 5e, 6, 6A, according to TIA 568-C.2 or TIA-1005 standards
ISO/IEC - C and D, E, EA level certification based on ISO/IEC 11801:2002 and revised standards
IEEE 802.3 - 10BASE-T, 100BASE-TX, 1000BASE-T, 10GBASE-T
General Specifications
Automatic testing speed Fully bidirectional automatic testing for Category 5e or 6/Class D or E: 9 seconds; Fully bidirectional automatic testing for 6A/EA class: 10 seconds
Supported testing parameters (testing standards determine the parameters and frequency range of the report) Wiring diagram, length, propagation delay, delay deviation, DC loop resistance, insertion loss (attenuation), return loss (RL), near end crosstalk (NEXT), attenuation crosstalk ratio (ACR-N), ACR-F (ELFXT), comprehensive ACR-F (PS ELFXT), comprehensive NEXT, comprehensive ACR-N
frequency 500 MHz
Test result storage 12000 Cat 6A with diagram
display screen 5.7-inch LCD with inductive capacitive touch screen
volume Host and intelligent remote unit: 2.625 inches x 5.25 inches x 11.0 inches (6.67 cm x 13.33 cm x 27.94 cm)
weight 3 pounds (1.36 kilograms)
battery Lithium ion battery pack, 7.2 V
battery life 8 hours, standard
Battery charging time 4 hours (below 40 ° C, the tester is turned off)
Supported Languages English, French, German, Italian, Japanese, Portuguese, Spanish, Simplified Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian
verify The calibration cycle of the maintenance center is one year
Integrated Wi Fi Compliant with IEEE 802.11 a/b/g/n requirements; Dual band (2.4 GHz and 5 GHz)
Environmental specifications
Operating Temperature 32 ° F to 113 ° F (0 ° C to 45 ° C)
Storage temperature -22 ° F to+140 ° F (-30 ° C to+60 ° C)
Relative humidity at work (% RH without condensation) 0% - 90%, 32° F - 95° F: (0° C - 35° C)
0% - 70%, 95° F - 113° F: (35° C - 45° C)
vibration Random, 2 g, 5 Hz -500 Hz
impact 1-meter drop test (with or without modules and adapters)
safety CSA 22.2 No. 61010, IEC 61010-1 3rd edition
altitude 13123 ft (4000 m) 10500 ft (3200 m) with AC adapter
EMC EN 61326-1: Portable
DSX2-602
DSX2-602 CableAnalyzer Main Tester and Intelligent Remote, Cat 6A/Class EA Channel Adapter (2), 6-inch (15 cm) RJ45 Reference Jumper (1), Portable Soft Pack, USB Computer Communication Cable, AC Adapter (2), and DSX2-600 Beginner's Guide
DSX2-602-PRO
DSX2-602 CableAnalyzer Main Tester and Intelligent Remote, Cat 6A/Class EA Channel Adapter (2), 6-inch (15 cm) RJ45 Reference Jumper (1), Cat 6A/Class EA Link Adapter (2), Portable Soft Pack, USB Computer Communication Cable, AC Adapter (2), and DSX2-600 Beginner's Guide