Experimental Rotary Sterilization System RSS-L1

Main applications
The main application
This product adopts the method of wet heat sterilization to fully sterilize the samples that require terminal sterilization, in order to ensure that the sterility level of the product meets industry standards or requirements. Widely used in industries such as food, daily chemical, pharmaceutical, etc.
This equipment uses the method of wet-heat sterilization to sterilize the samples which need terminal sterilization, so as to ensure that the sterility degree of the product meets the industry standards or requirements. It is widely used in food, daily chemical, pharmaceutical and other industries.
Introduction
Brief Introduction
This product is suitable for sterilizing samples that have already been prepared and placed in containers of specific specifications. By heating the sterilization water to 121 ℃ (or higher), and using a transfer pump and spray ball to heat and sterilize the sample with the heated superheated water, the sterile assurance level is improved, and the SAL is ≤ 10-6, thereby achieving effective sterilization effect.
This equipment is suitable for sterilizing samples that have been prepared and are loaded into specific specifications of containers. Heating the sterilized water to 121℃ (or higher) and then spray on the sample containers for sterilization. The superheated water is sprayed by conveying pump and spray ball. This can improve the sterility assurance level and make SAL less than 10-6, so as to achieve the perfect sterilization effect.

The container for holding samples during the sterilization process is fixed in a rotatable sterilization fixture, which ensures uniform heating of the samples and thus guarantees the uniformity of sterilization. There are specific temperature monitoring points set up in the sterilization system, which can effectively monitor and correct the temperature throughout the sterilization process, output sterilization curves, and ensure sterilization effectiveness.
In the sterilization process, the container containing the sample is fixed in the rotating sterilization fixture, which can ensure the uniformity of the sample heating, thus ensuring the uniformity of the sterilization. There are specific temperature monitoring points in the sterilization system, which can effectively monitor and modify the temperature of the whole sterilization process, output sterilization curve and ensure the sterilization effect.
Regarding F0value
AboutF0Value
F0Value refers to the comparative parameter used to verify the reliability of wet heat sterilization during the sterilization process. The reference temperature for wet heat sterilization is set at 121 ℃. Using the particularly heat-resistant thermophilic Bacillus subtilis as a microbial indicator, different temperatures and times are converted to the equivalent time (minutes) for wet heat sterilization at 121 ℃ with the same sterilization efficacy. This value is F0Value.
F0value refers to the comparative parameters used to verify the reliability of wet-heat sterilization in the sterilization process. The reference temperature of hygrothermal sterilization is 121℃, and Bacillus stearothermophilus with special heat resistance is used as microbial indicator. The different temperatures and times are converted to the equivalent time (minutes) of hygrothermal sterilization at 121℃ with the same sterilization efficacy, which is F0value.

Sterilization Decision Tree
STERILIZATION DECISION TREE

Technical Features
Technical Characteristics
Sterilization method: Wet heat sterilization
Sterilization method: wet-heat sterilization
Sterilization fixture: rotatable to ensure uniform heating of each sample
Sterilization fixture: rotatable to ensure uniform heating of samples
Number of temperature instruments:>3
Number of Temperature Instruments: >3
Temperature measurement: 0~150 ℃, ± 0.1 ℃
Temperature measurement: 0~150℃, ±0.1℃
Total power: 7.5kW
Total power: 7.5kW
Applicable sample total volume: 10ml~2000ml
Total Volume of Applicable Samples: 10ml~2000ml
Sample quantity: 1-10 pieces
Number of samples: 1~10
Voltage resistance: 0.3Mpa
Maximum pressure tolerance: 0.3Mpa
Data: Monitor and output process parameter values and curves (such as temperature, pressure, F0 value, time, speed, flow rate, etc.)
Data: Monitor and output process parameter values and curves (such as temperature, pressure, F0 value, time, speed, flow rate, etc.)
Regulatory compliance: Complies with hygiene standards, data, and validation requirements such as GMP and FDA
Compliance of Regulations: Complying with GMP, FDA and other health level, data and validation requirements.
Operation: Fully automated operation
Operation: Fully automatic operation.
modify the temperature of the whole sterilization process, output sterilization curve and ensure the sterilization effect.
Data output interface
Data Output Interface

———— / END / ————