Temperature Gauge Series>>WSSXElectric contact remote transmission bimetallic thermometer:

1、 Instrument Overview:
Electric contact remote transmission bimetallic thermometerIt is composed of bimetallic sheets wound into a circular curved shape. When one end expands due to heat, it drives the pointer to rotate, and the working instrument displays the corresponding temperature value, while preventing environmental vibration. The bimetallic thermometer is filled with silicone oil or separated from the measuring part to achieve shock resistance. Electric contact bimetallic thermometers are divided into two types: integrated seismic resistant electric contact bimetallic thermometers and separated seismic resistant electric contact bimetallic thermometers.
2、 Measurement principle:
Electric contact remote transmission bimetallic thermometerEquipped with electrical contact devices, namely mechanical electrical contacts. When the temperature of the measured medium changes, the thin shaft and steering transmission mechanism on the free end drive the pointer and moving contact to rotate, indicating the temperature change value on the dial. When it contacts or disconnects from the fixed contact (upper and lower limit fixed contact), the relay and contactor in the circuit system are activated to achieve automatic control and alarm purposes.
3、 Applicable occasions:
The bimetallic thermometer is a kind of detection instrument commonly used in occasions where the temperature on the production site is not very high. It can directly measure the temperature of gas and steam. The measured temperature is generally in the range of minus 80 ℃ -500 ℃. The design of the bimetallic thermometer has the characteristics of waterproof, anti-corrosion, shock resistance, direct reading, ruggedness and durability, and is widely used in industrial occasions such as petroleum, chemical industry, shipping, machinery, power generation, textile, printing, etc.
4、 Performance characteristics:
1. On site temperature display, intuitive and convenient; Safe and reliable, with a long service life;
2. Multiple structural forms can meet different requirements. Mercury free, easy to read, sturdy and shock resistant.
3. The protective pipe material is 1Gr18Ni9Ti stainless steel and molybdenum titanium, with strong pressure resistance and anti-corrosion ability.
4. The core pulling thermometer can be maintained or replaced for a short period of time without stopping the machine.
5. There are various types of integrated models including axial, radial, 135 °, universal, etc., which are suitable for various on-site installation needs.
5、 Technical indicators:
1. Measurement range: -80~40 ℃, -40~80 ℃, 0~50, 100, 150, 200, 250 ℃, or by the user;
2. Accuracy level: 1.5 level;
3. Work pressure: maximum usage pressure of 4.0Mpa;
4. F4 cladding thickness:~0.8mm, can also be customized by the user;
5. Quality inspection: using electric spark micro hole flaw detection, with a voltage of 12KV and a frequency of 1.6 × 106Hz without breakdown;
6. Material of metal protective tube: ICr18Ni9Ti; Or by the user;
7. Outer diameter of metal protective tube: Φ 6, Φ 8, Φ 10, Φ 12;
8. Connection size: (1) movable external thread: M27 × 2, G3/4,G1/2, Or by the user;
(2) Flange connection: DN15, 20, 25, etc, HG20593, Or by the user;
9. Indicator gauge outer diameter: D=Φ 80, Φ 100, Φ 150.
6、 Attention:
1. During storage, installation, use, and transportation, try to avoid collision with the protective tube and prohibit bending or deformation of the protective tube.
2. During installation, it is strictly prohibited to twist the instrument housing.
3. The instrument should operate normally within an ambient temperature range of -30 ℃ to 80 ℃.
4. The temperature at which the instrument frequently operates can be between 1/2 and 3/4 of the scale range.
5. The length of the protective tube immersed in the measured medium must be greater than the length of the temperature sensing element to ensure measurement accuracy.
6. Do not use for measuring media in open containers.
7. Pay attention to checking during use, which will take about 6 months.
7、 Electrical parameters:
Rated power (VA) |
Zui High Operating Voltage (V) |
Maximum allowable current (A) |
10 |
220VAC |
0.7A |
24VDC |
8、 Insulation resistance:
rated voltage |
Direct current test voltage (DC) |
insulation resistance |
24VDC |
100 |
7 |
220VAC |
500 |
20 |
Normal working atmospheric conditions: temperature-25-+55℃relative humidity≤85%.
Setpoint error: Setpoint error should not exceed the basic error limit1.5Twice.
Switching error: The switching error should not exceed the basic error limit1.5Twice.
9、 Technical Data Sheet:
Model number |
Temperature measurement range ℃ |
accuracy class |
Protective tube material |
Specification L (mm) |
Install fixed devices |
WSSX-400 |
-40-+80 0-+50 0-+100 0-+150 0-+200 0-+300 0-+400 0-+500 |
1.5 |
1Cr18Ni9Ti 304 316 316L Ha Shi C-276 |
75 100 150 200 300 400 500 750 1000 |
No fixed device |
WSSX-410 | |||||
WSSX-480 | |||||
WSSX-401 |
movable external thread |
||||
WSSX-411 | |||||
WSSX-481 | |||||
WSSX-402 |
Movable internal thread |
||||
WSSX-412 | |||||
WSSX-482 | |||||
WSSX-403 |
Fixed thread |
||||
WSSX-413 | |||||
WSSX-483 | |||||
WSSX-404 |
Fixed flange |
||||
WSSX-414 | |||||
WSSX-484 | |||||
WSSX-405 |
Card sleeve thread |
||||
WSSX-415 | |||||
WSSX-485 | |||||
WSSX-406 |
Card sleeve flange |
||||
WSSX-416 | |||||
WSSX-486 |
10Selection List:
serial number |
category |
Specification representation |
Instructions |
||||
WSS |
X |
Electric contact type |
Bimetallic thermometer (Zhongwei Measurement and Control) |
||||
Nominal diameter of dial |
-3 |
|
Φ60 |
||||
-4 |
|
Φ100 |
|||||
-5 |
|
Φ150 |
|||||
Dial form |
0 |
|
Axial (straight) |
||||
1 |
|
Radial (angular) |
|||||
2 |
|
135 ° direction (obtuse angle type) |
|||||
8 |
|
Wanxiang (adjustable angle type) |
|||||
Installation fixed form |
0 |
|
No fixed device |
||||
1 |
|
movable external thread |
|||||
2 |
|
Movable internal thread |
|||||
3 |
|
Fixed thread |
|||||
4 |
|
Fixed flange |
|||||
5 |
|
Card sleeve thread |
|||||
6 |
|
Card sleeve flange |
|||||
Protection form |
- |
|
普通型 |
||||
W |
|
protective type |
|||||
F |
|
corrosion-resistant type |
|||||
Selection example: Universal type, dial diameterΦ100Temperature measurement range0~400℃,1.5Grade, activity external threadM27×2, Length450mm.WSSX-481, 0~400℃,L=450,M27×2,1.5Grade.
11、 Ordering Notice:
1. Model number;
2. Accuracy level;
3. Temperature measurement range;
4. Installation fixed form;
5. Hot installation sleeve form;
6. Insert length.
After-sales service
1. The instrument series products sold by Zhongwei ensure the sale of products and spare parts at the same price within two years, and provide corresponding free of charge according to the requirements of the demand.
2. If there are any quality problems with the products provided by our company within one year (excluding vulnerable parts or accessories), we will be responsible for free repairs and provide free skill training for the employees of the demand side.
3. Due to quality issues with the products provided by our company, after verification by our technical department, we will dispatch professional technicians to the site to handle the problem until customer satisfaction is achieved.
4. Outside the warranty period, the product will be returned to the company for repair or sent to the user for repair.
5. Join hands with Zhongwei Measurement and Control to create a better future! Welcome to your visit!