DZ47-63 miniature circuit breakerThe DZ47 air switch is mainly suitable for circuits with AC 50/60Hz, rated operating voltage of 230V/400V and below, and rated current up to 63ACircuit breakerMainly used for overload and short circuit protection of electrical circuits and equipment in modern buildings, and also suitable for infrequent operation and isolation of circuits. Structural features: The DZ47-63 miniature circuit breaker consists of a plastic casing, operating mechanism, contact arc extinguishing system, trip mechanism, etc. The shell is made of high flame retardant and high-strength special plastic, with strong impact resistance and light weight. The components of the circuit breaker operating mechanism are made of high-strength plastic products, which ensure sensitivity and reliability while obtaining the lowest moment of inertia, making the time from the start of a short circuit fault to the action of the trip mechanism very short. The trip mechanism consists of two parts: a bimetallic overload inverse time trip mechanism and a short-circuit instantaneous electromagnetic mechanism. The contact arc extinguishing system adopts special arc angles and aisle extinguishing chambers, and has significant current limiting characteristics. Mainly used for overload and short circuit protection of lighting, distribution lines, and equipment in office buildings, residential buildings, and similar structures. It can also be used for infrequent line switching under normal circumstances.
This product meets the requirements of standards such as IEC60898 and GB10963.1.
The DZ47-63 miniature circuit breaker (DZ47 air switch) produced by Taixi has passed the national CCC certification and CE certification.
| PRODUCT MODEL | number of poles | Release type | Rated current |
| DZ47-63 | 1P | c | 63 |
|
|
1p 2p 3p 4p |
B: Type B C: Type C D: D-type
|
1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 6:6A 25:25A 63:63A |
3.1 The upper limit of the ambient temperature shall not exceed+40 ℃, the lower limit shall not be lower than -5 ° C, and the average temperature over 24 hours shall not exceed+35 ° C.
3.2 The altitude of the installation site should not exceed 2000m.
3.3 The relative humidity of the atmosphere shall not exceed 50% when the ambient air temperature is+40 ℃, and higher relative humidity is allowed at lower temperatures; For example, reaching 90% at+20 ℃. Special measures should be taken for occasional condensation on the product due to temperature changes.
3.4 Pollution level: Level 2.
3.5 Installation conditions: Installed in a location without significant impact or vibration, and in a medium without danger (explosion).
3.6 Installation method: TH35-7.5 installation rail is used for installation.
3.7 Installation category: Level II and III.
3.8 Wiring: Suitable for wire connections of 25mm2 and below.
3.9 Wiring method: Use screws to tighten the wiring with a torque of 2.0N · m.
Main specifications of DZ47-63 miniature circuit breaker (DZ47 air switch):
Divided by rated current ln: 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A.
Divided by Polarity (POLE): 1P. Unipolar; 2P. Two poles; 3P. Three poles; 4P. Quadrupole.
According to the form of instantaneous release of circuit breakers: a. B type (3ln~6ln); b. Type C (5ln~10ln); c. D-type (10ln~20ln).
Mechanical and electrical life: The circuit breaker is tested at a frequency of 120 cycles per hour (>32A) or 240 cycles per hour (≤ 32A) to make and break rated currents at a specified rated voltage, with a power factor of 0.85~0.9. Its electrical life is 4000 cycles and mechanical life is 10000 cycles.
Trip characteristic curve of DZ47-63 miniature circuit breaker
C-type release characteristic curve
D-type trip characteristic curve