model |
CZXT-225 |
Studio rulerD×W×H |
600×750×500 |
Overall dimensionsD×W×H |
850×1260×1560 |
performance metrics |
temperature range |
15℃~30℃ |
humidity range |
relative humidity50±5%R.Hwithin the scope of |
volatility |
≤±0.5℃ |
humidity deviation |
+2,-3%R·H |
warm-up time |
0.7℃~1.0℃/min |
cooling time |
0.7℃~1.0℃/min |
Humidity fluctuation |
±5%R.H |
temperature control accuracy |
±1℃ |
Mettler scale |
One in a hundred thousand, one in a million, optional |
Temperature and humidity operation control system |
controller |
Microcomputer touch screen temperature and humidity integrated controller |
precision range |
Setting accuracy: Temperature ±0.1℃、 湿度土0.1%R・H,Indication accuracy: Temperature ±0.1℃、 湿度土0.1%R・H |
Temperature and humidity sensor |
Platinum resistancePT100Ω / MV |
heating system |
Fully independent system, nickel chromium alloy electric heating heater |
humidification system |
External isolated, all stainless steel shallow surface evaporative humidifier |
dehumidification system |
Adopting evaporator coil dew point temperature laminar contact dehumidification method |
water supply system |
The humidification water supply adopts automatic control and can recover residual water.Water conservation and consumption reduction |
refrigeration system |
Fully enclosed single-stage compression refrigeration method/Original French "Taikang" |
circulatory system |
Temperature resistant and low-noise air conditioning motor.Multi blade centrifugal wind turbine |
Materials used |
outer box material |
Galvanized steel plate spray treatment |
Inner box material |
adoptSUS304mirror finish |
thermal insulation material |
Polyurethane rigid foam/Ultra fine glass fiber cotton |
Door frame insulation |
Double layer high and low temperature aging resistant silicone rubber door sealing strip |
Standard Configuration |
Attached lighting glass window1Set, test rack, test lead hole(50 The100mm)1a |
protection system |
Leakage, short circuit, overheating, water shortage, motor overheating, compressor overpressure, overload, overcurrent protection/Controller power outage memory |
Power requirements |
380V±10%;50 HzThree phase four wire+ground wire,Power supply inside the box:220V 50HZ |
Environmental temperature for use |
5℃~+28℃ ≤85%R·H |
|
For HJ836-2017 GB18325.3-2005, GB18352.5-2013, GB 18352.6-2016 Light duty Vehicle Pollutant Emission Limits and Measurement Methods, GB17691-2005 Vehicle Compression Ignition and Gas Fuel Ignition Engines and Vehicle Exhaust Pollutant Emission Limits and Measurement Methods, a high-precision balance is placed in a constant temperature and humidity chamber, and the weighed sample is placed in the constant temperature and humidity chamber to balance for a certain period of time before weighing. The constant temperature and humidity adjustment ensures the accuracy of the balance weighing sample results and the stability and accuracy of the sample weighing data. Non standard products can also be manufactured according to customer requirements. Note: 1. The above data are all at ambient temperature (RT) of 25 ℃. Measured under no-load conditions in the studio. We can customize non-standard low-temperature, constant temperature, and constant humidity laboratories according to specific user requirements.
|