Air bath constant temperature shakerdetailed introduction
The air bath constant temperature shaker (also known as the air constant temperature shaker) is a biochemical instrument that combines a temperature controlled constant temperature incubator and an shaker. It is mainly suitable for the oscillation cultivation of various liquid and solid compounds such as biology, biochemistry, cells, and bacterial strains in various universities, medical, petrochemical, health and epidemic prevention, environmental monitoring and other scientific research departments. Its main features are:
A: Accurate temperature controlDigital display.
B: Provide oxygen replenishment holes and a constant temperature working chamber with sufficient oxygen replenishment.
C: Equipped with mechanical timing.
D: The spring bottle rack is particularly suitable for the cultivation and preparation of biological samples for various comparative experiments.
E: Stepless speed regulation, smooth operation, easy and safe operation.
F: The inner cavity is made of stainless steel, which has good corrosion resistance.
Air bath constant temperature shakerModel * Main Technical Performance:
1、 Power supply: 220V 50Hz
2、 Heating power: 400w
3、 Timing range: 0-120 minutes (or normally open)
4、 Oscillation frequency: starting -300 revolutions per minute, adjustable
5、 Oscillation amplitude: 20mm
6、 Constant temperature range: room temperature -50 ℃
7、 Oscillatory methods: reciprocating, swirling, and dual function (to be selected during procurement)
8: Temperature control accuracy: 1 ℃
9: Bottled quantity: Test tube:? 16×300mm
100ml x 24 pieces, 200ml x 15 pieces
10: Dimensions: 700 × 470 × 500mm
Product Model:
(1) THZ-82 type, gas bath constant temperature oscillator: belongs to the reciprocating type
(2) THZ-82B type, gas bath constant temperature oscillator: belongs to the rotary type
(3) ZD-85 type, gas bath constant temperature oscillator: belongs to reciprocating and rotary, dual function.
Instructions Before Use
1. Please read this manual carefully before use.
2. The working surface of the machine should not be excessively smooth (such as tiles, etc.).
3. The electrical rated parameters of the socket provided by the user should not be less than the electrical rated parameters of the machine, and there should be good grounding measures.
4. The whole machine is strictly prohibited from being used in an environment with direct sunlight.
5. The speed control should start slowly from low speed to high speed.
6. The machine may experience some displacement during high-speed oscillation, so it should be monitored by someone during use.
Instructions for Use
1. Load the test bottle and maintain balance. If it is a dual function model, set the oscillation mode.
2. Connect the power and set the timer according to the surface scale of the machine. If you need to work for a long time, adjust the timer to the "normally open" position.
3. Turn on the power switch and set the constant temperature:
(1) Place the control switch in the "Settings" section, and the temperature displayed on the screen will be the set temperature. Adjust the knob to set it to the desired temperature for your work. (The working temperature you set should be higher than the ambient temperature. At this time, the machine starts heating up and the yellow indicator light is on. Otherwise, the machine will not work.)
(2) Place the control switch on the "measurement" end, and the temperature displayed on the screen will be the actual temperature of the air inside the test chamber. As the temperature inside the chamber changes, the displayed number will also change accordingly.
(3) When heated to the desired temperature, the heating will automatically stop and the green indicator light will turn on; When the heat inside the test chamber dissipates below the temperature you set, a new round of heating will begin.
4. Activate the oscillation device:
(1) Turn on the oscillation switch on the control panel, and the indicator light will turn on.
(2) Adjust the oscillation speed knob to the desired oscillation frequency.
5. Cut off the power after work, and set the speed control knob and temperature control knob to the low point.
6. Clean the machine and keep it clean.
6、 Precautions
1. Instruments should be placed on a sturdy workbench, with a clean and tidy environment and good ventilation.
2. The power socket provided by the user should have good grounding measures.
3. It is strictly prohibited to move the machine during normal operation.
4. It is strictly prohibited for objects to collide with the machine.
5. Children are strictly prohibited from approaching the machine to prevent accidents.
6. Before replacing the fuse, ensure that the power supply has been cut off.
7. After use, please clean the machine without leaving any water droplets or dirt residue.