ATDS-G51 fully automatic secondary pyrolysis gas chromatograph

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief description: The fully automatic secondary thermal desorption gas chromatograph is a fully automatic thermal desorption instrument (thermal desorption instrument) with electronic cold trap and secondary adsorption desorption function. It is equipped with multiple workstations such as 10, 20, 30, and 40 for users to choose from, and is specifically used for the analysis of ambient air.

Product Details

Fully automatic secondary pyrolysis gas chromatograph

Function and Features:

1. The fully automated system is safe and reliable, and does not require personnel to be on duty

2. Modular design of software and hardware, compact structure

3. Strong universal performance: can be used with almost all brands of gas chromatographs(GC)Gas chromatography-mass spectrometry(GC-MS)combination use

4. Simple human-computer interaction, easy operation, high degree of automation(The software automatically completes the desorption and injection analysis process of all adsorption tubes)Good repeatability of the sample

5. Equipped with industrial grade touch LCD screen, the interface information is rich and complete, the operation is simple, the method parameter is set, the working status and running time are displayed in real time, and the temperature and operation commands are tracked throughout the process

6. Adsorption tube, injection valve, transfer tube, focusing tube(Refrigeration and Heating)Both can be individually controlled for temperature,10Multiple methods for editing, storing, and calling at any time, one click automatic completion of sample analysis

7. Simple sample processing: The sample tube is detachable, making it easy to carry and collect samples in the field

8. The trap adopts semiconductor refrigeration+Air cooling, cooling temperature can reach up to-40(room temperature20time)

9. The six way valve and transmission pipeline link have no transmission cold points, and can be temperature controlled and heated to reduce sample loss and ensure sample integrity. It comes with standard sample preparation function

10. Provide a synchronization interface, which can synchronously start gas chromatography, mass spectrometry, and chromatographic data processing workstations while injecting samples. The device can also be started using external event programs. The six way valve injection method effectively reduces dead volume and ensures injection accuracy

11. The sample pipeline adopts silane inert treatment stainless steel pipe to reduce residual pollution

12. Equipped with leak detection and fault alarm functions

13. Equipped with automatic monitoring function for the service life of the focusing tube

14. The prominent cooling temperature and heating rate ensure accurate chromatographic peak shapes



Fully automatic secondary pyrolysis gas chromatograph

Performance indicators:

1. One desorption(Adsorption tube)Temperature control range: room temperature~420Step size1

2. Six way valve injection system temperature and control range: room temperature~220Step size1

3. Sample transmission pipeline temperature and control range: room temperature~220Step size1

4. Secondary desorption(Focusing tube)Temperature control range: room temperature~450Step size1Heating rate>3000/min

5. cold trap(Electronic semiconductor refrigeration)Temperature control range:-40~Room temperature, step size1No need for liquid nitrogen refrigeration

6. Temperature control accuracy:<±1

7. Temperature control gradient:<±1

8. Gas path pressure resistance:>0.4MPa

9. Sample grade:10/20/30bit double circle2*20bit optional

10. Backflow rate:0.1-100ml/min(continuously adjustable)

11. Simulated sampling flow rate:100ml/min

12. Sample desorption, blowing, injection, and blowback time:

Sample desorption time:0.01s1000min

Sample blowing time:0.01s1000min

Sample injection time:0.01s1000min

Backblowing time of pipeline:0.01s1000min

13. Timing range:1s1000min

14. Timing error: better than0.1%
15.
Analysis accuracy:RSD<2.5%(andGCRelated to performance and operational technology)
16.
Adsorption tube specification: diameter:Φ6mm/Φ6.35mm, Length:89mm

17. Synchronization signal output:2Road switch quantity, linkage switch time is12second

18. power supplyAC220V 50Hz

19. Power:800W(peak)

20. Instrument size:700×350×540mm

21. Instrument weight: approximately38kg


Common application areas and examples:

1. Analyze the composition of volatile aroma and flavor compounds in food, and determine residual substances and pollutants in food

2. Analyze the composition of thermally degradable compounds in solid matrices, such as plasticizers, additives, monomers, etc. in polymer materials(These degradation products of the samples were subjected to adsorption, pyrolysis, and separation Analysis and determination contribute to the investigation of arson cases)

3. Separate unwanted components from the sample matrix, such as residual solvents in pharmaceuticals, residual monomers in polymers, and other oligomers

4. Purposefully collect volatile components in the sample matrix, such as polluted atmosphere, salt, and sugar. The current typical application is to monitor the environment and collect volatile organic pollutants in the air using adsorption tubes(Benzene derivativesVOCs)wait

5. Used for special removal of solids and liquids(If soaked in cotton and placed in a tube)Analysis and determination

6. One thermal desorption, generally only used for lower boiling temperature components(C2C13)Inorganic andyongjiuGas is not easy to make. If using a low-temperature adsorption trap(Secondary thermal desorption)Can achieve boiling point

7. Secondary adsorption pyrolysis and absorption of samplesGC/MSCombined use, with a wider range of applications, can solve the analysis and determination of complex types of samples, including environment, materials, fuel resources, food, pharmaceuticals, polymers, and various other commodities, etc


TVOC Classic Spectrum:

荆和:TVOC二次解析TC管-谱图.png


Injection method: secondary thermal analysis(TCPipe)+Split injection

Detector:FID

Peak order:1N-hexane;2Benzene;3Trichloroethylene;4Toluene5Octene;6Ethyl acetate;7Ethylbenzene;8, p-xylene, m-xylene;9Styrene;10Ortho xylene;11Nonane;12Isooctanol;13Undecane;14Tetradecane;15Hexadecane;

Applicability: Compliant withGB/T 50325-2020TheGB/T 18883-2002