A dust particle counter is an instrument used to detect the number of dust particles per unit volume in a purified environment and measure the level of environmental purification.
Dust particle counterAll technical indicators meet the requirements issued by the General Administration of MetrologyJJF 1190 - 2008Verification Regulations for Dust Particle CounterGB/T6167-2007According to the requirements of the "Performance Test Method for Dust Particle Counter", the entire machine function is controlled and processed by a microcomputer, and the test results can be directly printed. The instrument has the characteristics of multiple functions, high measurement accuracy, fast speed, easy portability, and simple operation. The instrument can simultaneously measure the number of dust particles of multiple sizes in one sampling, and can choose to observe the number and changes of particles of a certain size, which is very convenient for researching, detecting, and evaluating various clean environments.
This instrument software has been developed in the United StatesFS-209EStandard, can automatically press95%Determine the cleanliness level with confidence and conduct testing100level~30Wan level is a testing instrument for clean workshops.
ZHJ-EThe dual-purpose AC/DC laser dust particle counter is a new product recently launched by our company, which has unique features and is currently the * product among similar products in China:
1.We use imported semiconductor laser tubes and imported semiconductor photosensitive receiver tubes to ensure sensitivity and response speed.
2.The core component of the instrument is the light scattering sensor, whose structure can significantly eliminate stray light in the cavity, greatly improve the signal-to-noise ratio, and make the measurement more accurate and reliable.
3.The confidence measurement of this instrument is the highest among all similar products in ChinaGP/T16292-194889Two conditions are used to automatically determine the purification level.
4.Can store1000A measurement data, which can be queried and equipped with a communication interface connected to a computer.
5.The instrument is equipped with temperature and humidity interfaces, which can be connected to corresponding temperature and humidity sensors to measure temperature and humidity simultaneously.
6.Among similar products in China, digital indicators are used for sampling flow, making it more intuitive and accurate.
ZHJ-E (LCD display) (AC)
Dust particle countertechnical indicators
| model | ZHJ-BIItype | ZHJ-BIIItype | ZHJ-Etype |
|
| sampling size | 2.83L/min | |||
| Testing Scope | purify100 Level -30 ten thousand level | |||
| measure particle size | 0.3; 0.5; 1.0; 3.0; 5.0; 10 (um)Six level particles | |||
| sampling period | 1~10minute | |||
| clean-down capability | ≤ 8minute | |||
| Print function | built-in printer(Can be directly printed into pieces/m3) |
| ||
| working environment | temperature10℃~35℃Humidity:20%~75%RHAtmospheric pressure<106KPa | |||
| Temperature and humidity function |
| Optional | have |
|
| Continuous working hours | ≤8hour | |||
| data storage |
| 1000Group data storage | ||
| power supply | AC220V50Hz | AC | ||
| power consumption | 30W | |||
| Overall dimensions(mm) | 250×205×125 | 260×205×125 | 260×205×125 |
|
| weight | 2.5kg | 3kg | 3kg |
|
| light source | Semiconductor laser light source | |||
| Public system transformation | have | |||
| Distinguish purification level | have | |||
| light source lifetime | Semiconductor Micro Light30000h | |||
2. ZHJ-L310ALaser dust particle counter(sampling size:28.3L/min)
ZHJ-L310AType is used to measure the size and number of dust particles per unit volume of air in clean environments, and can directly detect clean environments with cleanliness levels ranging from 300000 to 100. The instrument adopts a semiconductor laser light source, a large touch screen display, small size, light weight, high detection accuracy, simple and clear functional operation, microprocessor control, can store and print measurement results, and is very convenient for testing in a clean environment. Additionally, data can be downloaded and stored through computer software. The product is widely used in sectors such as electronics, optics, chemistry, food, cosmetics, healthcare, biological products, aerospace, etc.
Main technical parameters:
| Overall dimensions | 250?330?130(Wide)?tall?deep)(W?D?H) |
| display mode | LCD display |
| quality | 5.7Kg |
| Maximum power consumption | 60W |
| power supply | AC power supply220V±10%, 50Hz |
| Particle size channel | 0.3、0.5、1、3、5The10(μm),Simultaneous display of six particle sizes,It can also directly display particle concentration(unit:piece/cubic meter) |
| sampling flow | 28.3L/min (Imported sampling pump) |
| inspection cycle | 1?99999Choose in seconds |
| delay time | 0~60S |
| Continuous sampling frequency | 0?99time |
| interval | 0~99divide |
| clean-down capability | ≤10min |
| | Built-in Thermal Printer |
| alarm level | 10、100、1000、10000、10,0000、30,0000level |
| Environmental conditions for use | temperature:10~35°Chumidity:20%~75%RHAtmospheric pressure:86Kpa106Kpa |
| The maximum sampling concentration | 35000piece/L(≤0.5μm) |
| Continuous working hours | 8hour |
| Light source and lifespan | Semiconductor laser light source,Life expectancy greater than30000hour |
| data storage | 1000group |
3. ZHJ-L530type(sampling size: 50L/min)
ZHJ-L530Type is used to measure the size and number of dust particles per unit volume of air in clean environments, and can directly detect clean environments with cleanliness levels ranging from 300000 to 100. The instrument adopts a semiconductor laser light source, a large touch screen display, small size, light weight, high detection accuracy, simple and clear functional operation, microprocessor control, can store and print measurement results, and is very convenient for testing in a clean environment. Additionally, data can be downloaded and stored through computer software. The product is widely used in sectors such as electronics, optics, chemistry, food, cosmetics, healthcare, biological products, aerospace, etc.
Features:
⑴50Sampling volume per liter per minute ⑵Touch screen control operation
⑶Six channel particle size display simultaneously, displaying particle concentration (particles/m3)⑷USBinterface
Main technical parameters
| Overall dimensions | 240*330*200(Width, Depth, Height)Wide*Deep*High) |
| display mode | Touch screen display(LCD) |
| quality | 8Kg |
| Maximum power consumption | 60W |
| power supply | 220V 50Hz |
| Particle size channel | 0.3、0.5、1、3、5The10μm |
| calculate | 95%UCLCalculation, can directly display particle concentration (particles)/cubic meter) |
| sampling flow | 50L/min |
| inspection cycle | 1~9999sChoose between options |
| clean-down capability | ≤10min |
| measurement position | 0~9999 |
| | Built-in Thermal Printer |
| alarm level | ISO.100,1000,10000level |
| data storage | 1000Group (matching)PCMachine communication software) |
| data output | UDisk output |
| light source | Semiconductor laser light source (with a lifespan greater than)30000Hour) |
| The maximum sampling concentration | 35000piece/L |
| Continuous working hours | 8hour |
| Environmental conditions for use | temperature:10~35°Chumidity:20%~75%RHAtmospheric pressure:86Kpa~106Kpa |