hydrogen generator

NegotiableUpdate on 04/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The HP300 high-purity hydrogen generator produced by our company adopts membrane separation technology, which consists of an electrolysis system, a pressure control system, a purification system, a display system, and a protection system. It has passed relevant laboratory safety certifications. Widely used in laboratory analysis and testing departments such as petroleum, chemical, power, coal, *, environmental protection, food, commodity inspection, medicine, biotechnology, universities, research institutes, etc., supporting instruments such as gas chromatographs produced domestically and internationally. This instrument is specifically designed for use with foreign gas chromatographs, such as Agilent, Varian, Shimadzu, etc.
Product Details

HP300High purity hydrogen generator
Our company producesHP300 high-purity hydrogen generatorThe membrane separation technology used consists of an electrolysis system, pressure control system, purification system, display system, and protection system, which have passed relevant laboratory safety certifications. Widely used in laboratory analysis and testing departments such as petroleum, chemical, power, coal, *, environmental protection, food, commodity inspection, medicine, biotechnology, universities, research institutes, etc., supporting instruments such as gas chromatographs produced domestically and internationally.
By electrolyzing water, hydrogen gas can be produced with low flow rate, high purity, and stable pressure. It is an ideal gas source device for instruments such as gas chromatographs, used to replace hydrogen gas cylinders. It has the characteristics of small volume, light weight, simple structure, easy operation, safety and reliability, and is more suitable for use in remote areas and outdoor flow.
This instrument is specifically designed for use with foreign gas chromatographs, such as Agilent, Varian, Shimadzu, etc.
HP300 high-purityMain technical parameters
(1) Generate purity:99.999
(2) Output flow rate: 0-300mL/min
(3) Output pressure: 0-0.4MPa
(4) Power requirement: 220V/50Hz
(5) Zui High Power: 200W
(6) Dimensions: 330 ×170×380mm(L×W×H)
(7) Weight: 10kg
HP300 high-purity*Advantages
1. The instrument has automatic liquid level indication: four levels (25%, 50%, 75%, 100%) automatic liquid level indication is more intuitive and accurate than traditional U-shaped tube display.
2. Liquid level alarm function: When the liquid level in the electrolytic tank is too low, the 25% liquid level light changes from green to orange, indicating to the operator to add liquid. When the liquid level in the electrolytic tank is below 25%, the 25% liquid level light changes from orange to red, and the peak alarm beeps continuously. At this time, the operator should immediately add liquid.
3. Current protection function: When the switch power supply fails and the current output is too high, the protection device will operate to cut off the current and ensure that the electrolytic tank is not damaged.
4. High temperature protection function: When the electrolytic drum experiences abnormal high temperature, the protection device will activate, cut off the current, and ensure that the electrolytic drum is not damaged.
5. Drying tube lighting function: The instrument is equipped with a three channel LED lighting system for the drying tube. Even in the dark, the instrument can easily check the status of the discolored silicone inside the drying tube, which can be replaced in a timely manner to prevent excessive hydrogen humidity.
HP300 high-purityInstrument Features
(1) Overvoltage alarm system: When the pressure of the storage tank exceeds the maximum output pressure, the fault alarm light of the instrument will light up, and the buzzer will sound a long alarm and automatically cut off the hydrogen production current.
(2) Equipped with a non backflow device to ensure that the instrument has no backflow and can reduce the number of silicone gel replacements.
(3) Large electrolysis area and high hydrogen purity; Low barrel temperature results in longer membrane lifespan.
(4) The switch power supply of * achieves the highest electrolysis efficiency and produces large and stable gas.
(5) Simple daily operation and maintenance: After the instrument is online, simply turn on/off the power switch, and daily maintenance only requires adding liquid and replacing the color changing silicone gel.
(6) Overflow hole design, adding more liquid will automatically discharge.
(7) The traffic is displayed by LED digital display, which is intuitive and eye-catching.
(8) Integrated electrolytic tank, capable of storing liquid, electrolyzing hydrogen, and discharging oxygen simultaneously.
(9) Small size, beautiful appearance, can be placed in any position.
HP300 high-purityUse common sense
A: The dilution ratio of alkali to water is 1:5, and NaOH (sodium hydroxide) is used for alkali. The higher the purity, the better, and it should not be lower than the analytical purity; The minimum requirement for dilution water is distilled water.
B: After sealing the hydrogen outlet, the flow rate display should be "000" within five minutes. Otherwise, there is an internal leak in the instrument. Please check for leaks.