The HP500D high-purity hydrogen generator produced by our company adopts membrane separation technology, which consists of an electrolysis system, a pressure control system, a purification system, a display system, and a protection system. It has passed relevant laboratory safety certifications. Widely used in laboratory analysis and testing departments such as petroleum, chemical, power, coal, *, environmental protection, food, commodity inspection, medicine, biotechnology, universities, research institutes, etc., supporting instruments such as gas chromatographs produced domestically and internationally. Our company can provide OEM processing services for a wide range of agents. Interested parties please call us for inquiries.
HP300DHigh purity hydrogen generator
The HP300D high-purity hydrogen generator produced by our company adopts membrane separation technology, which consists of an electrolysis system, a pressure control system, a purification system, a display system, and a protection system. It has passed relevant laboratory safety certifications. Widely used in laboratory analysis and testing departments such as petroleum, chemical, power, coal, *, environmental protection, food, commodity inspection, medicine, biotechnology, universities, research institutes, etc., supporting instruments such as gas chromatographs produced domestically and internationally.
By electrolyzing water, hydrogen gas can be produced with low flow rate, high purity, and stable pressure. It is an ideal gas source device for instruments such as gas chromatographs, used to replace hydrogen gas cylinders. It has the characteristics of small volume, light weight, simple structure, easy operation, safety and reliability, and is more suitable for use in remote areas and outdoor flow.
Our company can provide OEM processing services for a wide range of agents. Interested parties please call us for inquiries.
(1) Generate purity:99.999%
(2) Output flow rate: 0-300mL/min
(3) Output pressure: 0-0.3MPa
(4) Power requirement: 220V/50Hz
(5) Zui High Power: 200W
(6) Dimensions: 330 × 170 × 380mm (L × W × H)
(7) Weight: 10kg
HP300D type*Advantages(Features that are not available domestically
1. Current protection function: When the switch power supply fails and the current output is too high, the protection device will operate to cut off the current and ensure that the electrolytic tank is not damaged.
2. High temperature protection function: When the electrolytic drum experiences abnormal high temperature, the protection device will activate, cut off the current, and ensure that the electrolytic drum is not damaged.
3. Liquid level tube lighting function: The instrument is equipped with a three channel LED lighting system for the liquid level tube, which can easily check the liquid level even in the dark, and can timely replenish the liquid to prevent dry burning.
HP300D typeInstrument Features
(1) Overvoltage alarm system: When the pressure of the storage tank exceeds the maximum output pressure, the fault alarm light of the instrument will light up, and the buzzer will sound a long alarm and automatically cut off the hydrogen production current.
(2) The liquid level display adopts a U-shaped tube display, which is intuitive and effective.
(3) Equipped with a non backflow device to ensure that the instrument has no backflow and can reduce the number of silicone gel replacements.
(4) Large electrolysis area and high hydrogen purity; Low barrel temperature results in longer membrane lifespan.
(5) The switch power supply of * achieves the highest electrolysis efficiency and produces large and stable gas.
(6) Simple daily operation and maintenance: After the instrument is online, simply turn on and off the power switch. Daily maintenance only requires adding liquid and replacing the color changing silicone gel.
(7) Overflow hole design, adding more liquid will automatically discharge.
(8) The traffic is displayed by LED digital display, which is intuitive and eye-catching.
(9) Integrated electrolytic tank, capable of storing liquid, electrolyzing hydrogen, and discharging oxygen simultaneously.
(10) Small size, beautiful appearance, can be placed in any position.
HP300D typeUsing common sense
A: The dilution ratio of alkali to water is 1:5, and NaOH (sodium hydroxide) is used for alkali. The higher the purity, the better, and it should not be lower than the analytical purity; The minimum requirement for dilution water is distilled water.
B: After sealing the hydrogen outlet, the flow rate display should be "000" within five minutes. Otherwise, there is an internal leak in the instrument. Please check for leaks.
Hangzhou Haipu Technology Co., Ltd
Address: Room 501, Building A, Weige Technology Park, No. 16 Xiangmao Road, North Software Park, Hangzhou, China, 85086279
: hzsyltech :310013
Comparison Table with Traditional Steel Cylinders
| | | Traditional steel cylinder |
| pressure | Constant pressure of 0.5MPa with no fluctuation output | The storage tank of 14MPa becomes smaller as it is used until there is no pressure |
| safety | The gas storage capacity is too small to detonate | It is easy to explode in the event of strong collisions, leaks, high temperatures, and other hazardous factors |
| Daily consumption | Pure water, electricity, and a small amount of soda ash | After the gas is used up, it needs to be transported to a professional production unit for filling, and the transportation cost is waiting for the gas to be used. The gas cost is the cost of damaging the pressure reducing valve |
| Cost consumption | Water, electricity, alkali, and instrument maintenance fees (calculated based on a gas consumption of 150ml/min for 8 hours per day, with all expenses including less than 10000 yuan after 5 years). | Steel cylinder fee, gas fee, pressure reducing valve fee, transportation fee (calculated based on a gas consumption of 150ml/min for 8 hours per day, with a total cost exceeding 18000 yuan after 5 years, excluding time loss waiting for gas consumption). |
| certification | Easy access to all laboratory management certifications | It can be certified through laboratory management, but the steel cylinder should be placed in a separate location away from hazardous factors |
| daily use | Simple and convenient | Relatively simple |
| Installation environment | Can be installed at close range with instruments of gas phase | Place it in another independent space and take protective measures such as high temperature prevention, anti slip, ventilation, and sun protection |
HP300D typeMain technical parameters