| Specifications | 60/2 | 60/3 | 60/5 | 120/2 | 120/5 |
| Rated voltage (kV) | 60 | 60 | 60 | 120 | 120 |
| Rated current (mA) | 2 | 3 | 5 | 2 | 3 |
| Rated power (W) | 120 | 180 | 300 | 240 | 360 |
| Whole machine weight (kg) | 9 | 10 | |||
| Whole machine weight (kg) | 465*390*190 | 565*390*190 | |||
| Height of pressure doubling cylinder (mm) | 440 | 535 | |||
| Output voltage accuracy | ± (1.0% reading ± 2 words) | ||||
| Output current accuracy | ± (1.0% reading ± 2 words) | ||||
| ripple factor | ≤0.5% | ||||
| working method | Intermittent use, rated load for 30 minutes | ||||
| overload capacity | The no-load voltage can exceed the rated voltage by 10% and be used for 10 minutes. The charging current is 1.25 times the rated current | ||||
| power supply | AC220V±10% 50HZ | ||||
| working environment | Temperature: -10-40 ℃ | ||||
| Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation) | |||||
| Altitude: below 1500 meters | |||||
Selection Reference - Zinc Oxide Surge Arrester DC Reference Voltage and Leakage Current Test
| Rated voltage of lightning arrester (kV) | 10 | 35 | 66 | 110 | 220 |
| DC reference voltage kV | 28 | 90 | 135 | 168 | 314 |
| Equipment selection kV/mA | ZGF - 60 / 2 | ZGF- 120 / 2 | ZGF- 200 / 2 | ZGF- 200 / 2 | ZGF- 400 / 3 |
Selection reference - choose according to the voltage level of the substation
| Substation voltage level kV | 10 | 35 | 66 | 110 | 220 | 330 |
| Test voltage kV | 47 | 105 | 135 | 192 | 305 | more than 400 |
| Equipment selection kV/mA | ZGF- 60 / 2 | ZGF- 120 / 2 | ZGF- 200 / 2 | ZGF- 200 / 2 | ZGF- 400 / 3 | ZGF- 800 / 10 |
Selection reference - choose based on the qualification level of repair and testing
| Maintenance and testing level | Level 5 | Level 4 | Level 3 | Level 2 | Level 1 |
| Test voltage kV | 28 | 90 | 168 | 305 | more than 400 |
| Equipment selection kV/mA | ZGF- 60 / 2 | ZGF- 120 / 2 | ZGF- 200 / 2 | ZGF- 400 / 3 | ZGF- 800 / 10 |
Selection reference - DC withstand voltage and leakage current test of paper insulated cable
| Rated voltage of cable Uo/U kV | 3.6 / 6 | 6 / 6 | 6 / 10 | 8.7 / 10 | 21 / 35 | 26 / 35 |
| DC test voltage kV | 17 | 30 | 40 | 47 | 105 | 130 |
| Equipment selection kV/mA | ZGF- 60 / 2 | ZGF- 60 / 2 | ZGF- 60 / 2 | ZGF- 60 / 2 | ZGF- 120 / 3 | ZGF- 200 / 5 |
Selection reference - Rubber insulated cable DC withstand voltage and leakage current test
| Rated voltage of cable Uo/U kV | 6 / 10 | 8.7 / 10 | 21 / 35 | 26 / 35 | 48 / 66 | 64 / 110 | 127 / 220 |
| DC test voltage kV | 26 | 37 | 63 | 78 | 144 | 192 | 305 |
| Equipment selection kV/mA | ZGF- 60 / 2 | ZGF- 60 / 2 | ZGF- 120 / 5 | ZGF- 120 / 5 | ZGF- 200 / 5 | ZGF- 200 / 10 | ZGF- 400 / 5 |
Selection reference - DC withstand voltage and leakage current test for main insulation of self accommodating oil filled cable
| Rated voltage of cable Uo/U kV | 48 / 66 | 64 / 110 | 127 / 220 | 190 / 330 | 290 / 500 |
| DC test voltage kV | 175 | 275 | 475 | 585 | 775 |
| Equipment selection kV/mA | ZGF- 200 / 3 | ZGF- 300 / 3 | ZGF- 500 / 5 | ZGF- 600 / 5 | ZGF- 800 / 10 |