Xenon lamp aging test chamber is a device that simulates and strengthens the aging damage caused by environmental factors such as solar radiation, temperature, humidity, condensation, and rain in natural climate, observes and analyzes the changes of non-metallic materials, organic materials (paint, coatings, rubber, plastics), etc. This test chamber is used to conduct experiments on the effects of ground solar radiation on equipment and components, simulating the environment

Xenon lamp aging test chamberThe model and performance
| model | SN-500 (air-cooled type) | SN-900 (water-cooled type) |
| studio dimensions(D×W×H) | 500*760*500 | 950*950*850 |
| outer dimensions(D×W×H) | 1030*1090*1640 | 1440*1260*2060 |
| performance metrics | blackboard temperature | 63℃~100℃±3℃ |
| humidity range | 50%~98% R.H |
| rainfall duration | 1~9999min, Continuous rainfall adjustable |
| Rainfall cycle | 1~240min, Interval (interval) rainfall adjustable |
| rainwater pressure | 0.12~0.15Mpa |
| Xenon lamp power | 1.8KW x 3=5.4 KW |
| Temperature and humidity operation control system | Time controller | Imported programmable time computer integrated controller |
| heating system | Independent system, nickel chromium alloy electric heating heater |
| humidification system | External isolated, all stainless steel shallow surface evaporative humidifier |
| blackboard temperature | Bimetallic blackboard thermometer |
| water supply system | The humidification water supply adopts automatic control, and the xenon lamp cooling circulating water is used |
| Temperature Controller | Imported microcomputer temperature and humidity integrated controller |
| circulatory system | Temperature resistant and low-noise air conditioning motor, multi blade centrifugal fan |
Xenon lamp aging test chamberEnvironmental conditions for use:
- The ground is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust
- There is no strong electromagnetic radiation source nearby
- There is a drainage floor drain near the equipment (within 2 meters of the refrigeration unit)
- Leave appropriate maintenance space around the equipment
- Temperature: 5 ℃~30 ℃
- Relative humidity: ≤ 85% RH
- Air pressure: 86-106kpa
- Power supply: 380V ± 10%, 50Hz ± 1%, three-phase five wire system
- Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must be independent and dedicated for the use of this equipment
- When the equipment is not working, the ambient temperature should be kept within+0-45 ℃. When the ambient temperature is below 0 ℃, the water remaining in the equipment should be discharged completely
Precautions:This device cannot be used to test or store items containing flammable, explosive, or volatile or corrosive gases.