XR3000 fiber optic spectrometer

NegotiableUpdate on 03/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
XR3000 is a fiber optic spectrometer based on CT optical path design. The detector adopts a Hamamatsu infrared enhanced area array CCD, with an effective spectral range of 780nm-1070nm. This spectrometer mainly uses 785nm Raman spectroscopy for measurement and is suitable for qualitative and semi quantitative Raman spectroscopy detection.
Product Details

XR3000 is a fiber optic spectrometer based on CT optical path design. The detector adopts a Hamamatsu infrared enhanced area array CCD, with an effective spectral range of 780nm-1070nm. This spectrometer mainly uses 785nm Raman spectroscopy for measurement and is suitable for qualitative and semi quantitative Raman spectroscopy detection.

Feature List

◆ Compact size: Size: 94 × 72.5 × 42mm, weight only 420g;

◆ High resolution: resolution between 8-12nm-1

◆ High sensitivity: high-performance backlit area array CCD;

Good thermal stability: spectral wavelength shift<3cm-1@ 0-40nm。

description

Product parameters
project price
size 94×72.5×42 mm
weight 420g
spectral range 780nm-1070nm(0-3400cm-1
resolution <0.7nm
Signal to Noise Ratio 450:1@100ms 85% Full signal
dark noise ~30RMS@ 100ms
integration time 8ms-30s
dynamic range 7800:1@100ms(single acquisition)
wavelength stability 0.1nm@0-40 ℃
slit W25μm,H400μm
detector Hamamatsu S11510-1106
A/D resolution 16-Bit
power consumption 220mA@5V
CCD pixels 2048×64
output interface Mini USB
operation temperature 0-40℃
Working humidity 5%-80%

Product appearance

Other information

resolution

Standard wavelength value (nm)

Actual wavelength value (nm)

Resolution (nm)

Deviation (nm)

826.452

826.28

0.87

-0.17

842.465

842.34

0.83

-0.12

852.144

852.12

0.83

-0.02

866.794

866.93

0.75

0.13

912.297

912.2

0.69

-0.09

922.45

922.46

0.70

0.01


Test conditions

ØLight source: HG-1 (Ocean Optics, Mercury Argon Gas Discharge Lamp)

ØFiber optic: 200 μ m VIS-NIR


dark noise

image.png


thermal stability

image.png

Test conditions

ØLight source: HG-1 (mercury argon gas discharge lamp)

ØFiber optic: 200 μ m VIS-NIR fiber, SMA905 connector

ØHigh and low temperature environment enclosure, continuous variable



sensitivity

image.png

Measurement conditions:

ØLaser power applied to the sample: 350mW

ØIntegral time: 1 second

ØTest sample:More than 99% analytical pure ethanol


Operating software(Uspectral-PRO)

image.png


Operation steps

1.Install on computerUspectralPro software, during the software installation process, will automatically install the spectrometer driver program;

2. Connect the fiber optic input signal to the spectrometerSMA905 interface;

3. UseConnect the spectrometer to the computer using a USB data cable;

4. Open itUspectralPro software is used for data collection and analysis (please refer to the UspectralPro software user manual for detailed instructions).


application area

vRaman detection

vDrug stimulation

vMedical analysis

vmaterial analysis

vOptical Experiment Teaching

vSpecial scientific research