E-mail
huawei027@126.com
-
Phone
15827257292,13545873066
-
Address
Building 2, Aofuduo Industrial Park, Wuhan Economic and Technological Development Zone
Wuhan Andexin Testing Equipment Co., Ltd
huawei027@126.com
15827257292,13545873066
Building 2, Aofuduo Industrial Park, Wuhan Economic and Technological Development Zone
Wuhan constant temperature and humidity test chamber merchantTechnical Specifications:
1. Model: ADX-TH-100L
2. Control system: Balanced temperature control system
3. Temperature range: -40 ℃ to 150 ℃
4. Temperature fluctuation: ± 0.5 ℃
5. Temperature deviation: ± 2.0 ℃
6. Heating time: RT~150 ℃ for about 45 minutes or less
7. Cooling time: RT~-40 ℃ for about 60 minutes or less
8. Inner box size (mm): W × H × D 1000 × 1000 × 1000
9. Outer box size (mm) 1510 × 2200 × 1600
10. Inner box material: SUS304 high-grade stainless steel plate
11. Outer box material: baked paint
12. Thermal insulation material: high-density polyurethane foam and glass fiber
13. Refrigeration system: air-cooled single-stage/stacked, fully enclosed compressor, environmentally friendly refrigerant (R404a/R23)
14. Controller: TEMI880 temperature controller is used
Wuhan constant temperature and humidity test chamber merchantProduct Features
1. The refrigeration unit adopts the original French "Taikang" fully enclosed compressor.
2. The refrigeration system adopts a unit or binary low-temperature circuit system design.
3. Adopting a multi wing air supply fan for strong air circulation, avoiding any dead corners, can make the temperature distribution in the testing area uniform.
4. The design of wind path circulation for air outlet and return ensures that the wind pressure and speed meet the testing standards, and can quickly stabilize the temperature at the moment of opening the door.
5. Heating, cooling, and system independence can improve efficiency, reduce testing costs, increase lifespan, and decrease failure rates.
6. The temperature control adopts a fully imported touch button instrument, with simple operation and setting.
7. After inputting the data and experimental conditions, the controller has a locking function to prevent human touch from changing the temperature value.
8. Equipped with P.I.D automatic calculation function, it can immediately correct temperature change conditions, making temperature control more accurate and stable.
9. Optional printer.
Air conditioning system:
1. Air conditioning method: Forced ventilation internal circulation balance temperature control (BTC), which refers to the control system automatically calculating the output of the heater based on the set temperature point through PID calculation under continuous operation of the heating system, ultimately achieving a dynamic balance.
2. Heating method: Nickel chromium alloy electric wire heating, PID regulation, actuator: solid-state relay
3. Air circulation device: centrifugal fan, long axis external motor drive.
Security protection system:
1. System control circuit fuse
2. Equipped with a non fuse protection switch
3. Overheating protection switch
4. Overload protection device for refrigeration compressor
5. System overcurrent protection device
6. Fault indicator light
7. Controller setting error, fault display and warning