Wireless Instrument User Manual
11/28 0.1version
1: Main characteristics of the instrument
1,ADadopt24bitHigh precision and low-noise chip, approximately100Wannei Code ensures accurate weighing
2,ADFUltra low power consumption, average sleep mode80uADynamic power saving during operation, ultra long distance, using spread spectrum communication, strong resistance
3Wireless bidirectional control, conventional communication distance1000riceAbove, the instrument automatically controls the on/off of the scale body,ADFThe transmission power can be adjusted, and the farthest communication distance can reach5Kilometers.
4The large screen dot matrix display can display all Chinese national standard level one and two Chinese characters, English, numbers, and various symbols, with backlight
5,There are needle and thermal printing options, multiple printing formats to choose from, and label printers can be equipped, can print all Chinese characters, English, numbers, and various symbols
6, using64Channel wireless module ensures no interference on the same frequency
7,ADThe launch and instrumentation adopt intelligent power management to extend battery working time
8,Adopting a specialized dynamic algorithm for hanging scalesIntelligent filtering to solve inaccurate weighing caused by object shaking
9,Calibration data is saved inADFThe instrument is universal, and there is no need to adjust parameters or calibrate when changing the instrument.
10,Internally, it is suitable for automatic printing parameter adjustment at the dock, especially for automatic weighing at the dock.
11The accessories can be equipped with wireless large screens and computer weighing management software,Add wireless large screen configuration, simple configuration, no need to install modules inside the instrument panel. (6.9or6.9Above version)
12,Multiple serial output formats are available, including Wantai and Yaohua continuous output formats, and print only output formats.
13,ADFBattery type selectable(3.6Lithium battery4.2VLithium battery4VLead acid battery,6VThe battery can be charged for a year without using a super lithium battery.
14, optional4-20MAAnalog port output, convenient for digital adjustment.
15, with classification storage function, can store100Each item number can be999poundSecondary, total storage5000time
2: Instrument serial port output
The serial port isN,8,1 The baud rate can be set, please do not modify the serial port parameters on the thermal printer model
1Wantai Continuous1Format Protocol
K1:0X5A—start position
K2:
7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
Symbol bit(1--Negative,0Positive) |
Under voltage prompt |
decimal point |
BCD10000 bits of data |
||||
The weight data isBCDCode, with one decimal place rounded to the nearest decimal place001Both of you are010
K3: BCDHigh level of data4Display thousands of digits, low4One hundred positions
K4: BCDHigh level of data4Display ten digits, low4Position by position
K5:K1—K4The result of XOR verification is then XORed0XA5
K1(0x5A) |
K2 |
K3 |
K4 |
K5 |
2: Wantai format2Print Output Protocol ASCIIcode
Protocol initiation02 Item Number2bit serial number3bit year, month, day, hour, minute10bit positive and negative0x2D/0x20 6Weight in digits, including decimal point Validation (previously)23Take a dozen or so digits)0x0d,0x0a
3Yaohua format, continuous output
Data inASCIIOutput in code format, with a total of data per frame9Composed of bytes (including decimal point). Data transmission starts with low bits and ends with high bits, with a set of separators between each frame of data“=Send data as net weight, if the current net weight is70.15, continuously sending51.07000= 51.07000=……,If it is -70.15, continuously sending51.0700—=51.0700—=......
=display10000
=display6742
8.147600= display6741.8
4Thermal printing protocol, and the serial port can also output printing data, which can be connected to external printers and computers
3: Instrument button usage
Power on/Reset: Turn on the instrument power supply/Reset.
Shut down/Cancel "has a shutdown effect in the main screen state, while other states cancel the current operation.
Backlight/Confirm: Confirm the current operation from the data settings or text input, and turn on the backlight from the main interface.
Check/Delete: Under the main screen, you can enter the inspection menu and seeADFThe software version and settings have a deletion effect during text input.
'Settings': You can enter the settings menu on the main screen, and switch between input methods for text input.
Set to zero: Make the current displayed weight equal to0The text input status is0digital input.
'Peeling': can remove the current weight as tare weight
Accumulation: When printing is not required, manually press the accumulation button to store the current weight
'Cumulative Display': displays the weight and weight information of the current goods, as well as the unit price and total price of the goods. When the total weight is displayed cumulatively, press the print button to print the total weight of the goods
Press cumulative display, then press print to print the cumulative weight of the current item number
For example:
Item Number:2
----------------------------
Fatigue and weight:123456.0Kg
'Item Number': Set the current cargo category number and range0-99After changing the item number, printing, accumulating, and listing are all done for this item number (item number is used to classify and store goods for printing)
Number: Number can be set10One, can input Chinese characters, numbers, symbols, etc., display the current number according to1-9Print the selected number(Number usage method: The number can be used as the model and specification of the goods. When printing the model rules, enter the number and select0-9Number printing)
'tare weight ': If the tare weight value is known, the tare weight can be manually set, and after setting, the weight value will automatically subtract the tare weight value.
'Heading': It is a pre printed heading that allows for the setting of company names and other information.
'Paper feed': Press once to feed the paper1CM.
'Print': Press' Print 'while weighing to print and store the current weight value.
![]()
![]()
![]()
『 When inputting Chinese characters, move the cursor left and right and select up and down.
4: Instrument function usage
Settings Menu1(Press the settings button once to enter)
0Set button sound, enter, press any number key to modify, press confirm to save settings, press cancel to exit without modification
1,Set the time and date, enter the correct year, month, day, and week in sequence, and time(24Hourly system). Press confirm to save the settings, press cancel to exit without modification.
2,Limit weight, only values smaller than the current full-scale limit can be entered. When the displayed weight exceeds the limit, the instrument will display99999The buzzer sounds an alarm.
4Exhaustion refers to subtracting the incorrect weight value of the current item number from the input serial number
5Accumulate all the weight data of the current item number
Clear the weight of the current item number without deleting the weight of other item numbers
6,Total accumulation: Accumulate the weight data of all item numbers
This function should be used with caution, otherwise all weight data will be cleared
7Set unit price: Set the current price of the goods,xyuan/ton
Automatically calculate the price based on the unit price
7,Printing: Set the printing format, including simplified printing, standard printing, and label printing (requires a label printer)
Simplified printing Standard printing
Weighing and Measuring Sheet Weighing and Measuring Sheet
serial number time weightkg Serial number:001
002 00:00 1000.0 Date:2008-04-28
003 00 00 3000.0 Time:24:00:00
004 00 00 2000.5 tare:500Kg
005 00 00 3000.5 Net weight:1000Kg
Settings Menu2(Press the settings key twice to enter or press →)
0calibration
When weighing is not accurate, calibration is required (new scales do not need calibration, they are calibrated with weights at the factory)
Calibration requires professional metrologists and weights
choice0Enter, then enter the password to enter the current empty scale state. The internal code of the empty scale should be in18000-30000Left and right, wait for the internal code value to stabilize and press confirm, then enter the weight value from left to right. Please enter the blank value in front of it0After entering the correct weight value, press confirm. Then hang the weight on the scale and wait for the internal code value to stabilize before pressing confirm. Multiple corrections and calibrations are required. Please enter the weight of the legal code again. If no correction or calibration is needed, press confirm directly and enter the tonnage of the scale body,5TJust enter05,10TJust enter10Confirm the end of calibration,
If prompted for calibrationOKRepresents completion. Then print out the calibration data, which can be archived and replaced laterADFNo calibration required.
1Gravity correction: refers to the magnification factor10000
2Accumulated mode:0Cancel automatic,1It is storage and printing,2It only stores
3Parameter settings: require professional personnel to modify, customers are not allowed to modify, please refer to the parameter page for details
3,Set automatic: The parameters set in it for automatic printing can be used in ports and other automatic printing places, and this instrument will automatically print After years of practice, the printing effect has high dynamic accuracy.
0: Printing mode Choose whether to turn on automatic mode or accumulate mode modifications
1: Minimum Printing Set the minimum printing weight, which is also a parameter for determining the return to zero
2: Stable range Set the dynamic range for stable identification to appear, and automatic printing determines whether to print based on the stable identification
3: Number of printed copies In standard printing mode, multiple weight sheets can be printed by pressing the print button once, which is equivalent to copying and printing
4Printing time What is the waiting time for the stable label to appear before automatically printing? This parameter is related to Stable range combined with debugging can improve automatic printing accuracy
5Title: Can be set10Set the company name, goods name, model, etc. in the header and print them out in the printing header
6,Dividing value: Modify the dividing value, enter the number before the dividing value to select the current dividing value. Please do not set the dividing value too small, as the actual accuracy has not improved, which will result in slow stability. The national standard for hanging scales is3Thousand degree division.
7Print a list: Print all the weights of the current item number or print the weights within the set date and time range.
This function can help customers print multiple weighing sheets For example:
Item No.2
------------------------------
serial number time weightkg
01 12:34 12345
02 12:34 12345
03 12:34 12345
04 12:34 12345
-----------------------------
Fatigue and weight:123456kg
5: Simple fault diagnosis
1, The instrument is not receiving a signal
1Check if the scale body battery is charged 2Can the correct channel be found through channel search? If the correct channel can be found, it means that both transmission and reception are normal. Simply switch to the appropriate channel
2, The instrument does not turn on
1Check if the instrument panel is out of power 2Check if the instrument is flooded or damp 3Check if the buttons are damaged
3, Inaccurate weighing or fluctuating weight
1Check if there is interference from the scale body at the same frequency in the attachment, switch the instrument and scale body channels (frequency interference display shows regular and repeated weight fluctuations) 2Check if the instrument is set to tare weight 3Check the plug of the scale body sensorADFIs there any looseness or water ingress on the upper part
4, Not printing or printing with unclear handwriting
1Check if the instrument panel has sufficient power 2Printing is not qualified
6: Parameter settings
0: Communication settings Set serial port and wireless communication parameters
0:ADFtransmit power Set according to the actual situation, there are0-3A level,3For the farthest distance2More than kilometers, butADFElectricity consumption will also increase.
1:ADFBattery Type 0:4Vlead-acid battery
1:4.2Vlithium battery
2:3.6VLithium ion battery (non rechargeable, can work for one year) 3:6Vbattery
Note:1We need toADFModifications can only be made while in communication with the instrument panel2The battery type is6VIn the current state, it is necessary to use6VThe battery needs to be powered on before it can be changed to4VLow voltage battery types
2Serial port baud rate:1200-9600Settings
(Please do not modify the thermal printer type, the printer needs to be used)
3Communication Protocol: Multiple communication protocols for easy connection to computers and other devices
(Please do not modify the thermal printer type, the printer needs to be used)
4Wireless large screen: whether to configure a wireless large screen
5: Large screen channel: Wireless large screen channel65-99Choose directly.
1Scale body channel Set the scale channel, and if there is a same frequency situation, the scale channel can be modified.
Note:1We need toADFModifications can only be made while in communication with the instrument panel
2For instruments without address code models, please modify the scale channel by moving the scale and instrument away from scales on the same frequency.
2:4-20MAZero position: setting4-20MAThe zero position output of analog quantity and the full range output are automatically based on the full range of the scale body
3: Zero setting range: Key zero setting range
4Zero position tracking: Set zero position tracking according to the actual situation when the sensor fails to return to zero
5Unit of measurement:LB(pounds),KG(kg) selection
6Channel Search: If you don't know the scale channel, you can use channel search to find the scale channel. After finding the scale channel, you need to configure it7Set it up in the instrument channel.
7,Instrument Channel: Set the instrument receiving channel, which is similar to the scale bodyADFOnly when the channel is the same can weight data be received
8,Change password: Calibration password, parameter password, and coefficient password can be set.