Wholesale of series thermal conductivity analyzers
Product Features
·Adopting corrosion-resistant imported sensors, anti cross interference, and * digital processing technology;
·Specially designed low drift bridge with high stability and strong reliability;
·Full Chinese human-machine menu, intuitive and convenient operation;
·The alarm point can be set arbitrarily within the full range;
·Standard RS232 or RS485 communication port (optional), capable of communicating with computers.
Wholesale of series thermal conductivity analyzersTechnical Specifications
Measurement range: 0.01% -5%/10%/50%/100% H2(N2Background gas
Accuracy: ≤± 2% F.S
Stability: Zero drift ≤ ± 2% F.S/7d,
Range drift: ≤± 2% F.S/7d
Repeatability: ≤± 1% F.S
Preheating time: ≤ 10 minutes
Response time: T90≤5S
Sample gas flow rate: 200~400ml/min
Sample gas pressure: 0.035Mpa ≤ inlet pressure ≤ 0.21Mpa
Output signal: 4~20mA DC
Working environment: Temperature: 0 ℃~45 ℃; Humidity: ≤ 80% RH
Working power supply: AC 220 ± 10% V.AC, 50Hz, power consumption less than 15VA
Dimensions: 482.5mm × 177mm × 300mm (W × H × D)
Instrument weight: approximately 4kg
Application fields:
The volume percentage content of hydrogen in the supplementary gas and circulating gas in the process of synthetic ammonia production in fertilizer plants
Volume percentage content of hydrogen in the production process of fertilizer plants
Volume percentage of excess hydrogen in the argon production process
Volume percentage content of hydrogen in the circulating gas of hydrogen cooled generators in power plants
Volume percentage content of hydrogen in ambient air and air inside industrial containers
Volume percentage content of argon in ammonia distillate
Volume percentage of argon in crude argon
Tested components |
Hydrogen (H2) |
Argon gas (Ar) |
Carbon dioxide (CO)2) |
|||
|
Background gas
serial number |
Nitrogen (N)2) |
Air (Air) |
Argon gas (Ar) |
Oxygen (O) |
Nitrogen (N)2) |
Air (Air) |
1 |
0~5 |
0~4 |
0~3 |
0~15 |
0~15 |
0~20 |
2 |
0~10 |
80~100 |
0~4 |
0~20 |
0~20 |
0~30 |
3 |
0~20 |
|
0~5 |
0~30 |
0~30 |
0~50 |
4 |
0~30 |
|
0~10 |
0~50 |
0~50 |
0~80 |
5 |
0~50 |
|
0~15 |
0~80 |
0~80 |
0~100 |
6 |
0~80 |
|
0~20 |
0~100 |
0~100 |
80~100 |
7 |
0~100 |
|
0~30 |
0~15 |
80~100 |
0~20 |
8 |
30~80 |
|
0~50 |
|
0~15 |
|
9 |
40~70 |
|
0~80 |
|
|
|
10 |
50~80 |
|
0~100 |
|
|
|
Special supply can be provided according to the needs of users
Ordering Notice (Please specify when placing an order)
Instrument measurement range
Tested gas pressure: positive pressure, slight pressure, or negative pressure
Main components, impurities, and sulfides of the tested gas