Implement the standard water quality COD online water quality analyzer for sewage treatment plants and water treatment plants. nGB11914-1989 "Determination of Chemical Oxygen Demand in Water Quality, Method" nHJ/T 377-2007 "Chemical Oxygen Demand (CODcr) Online Automatic Monitoring Instrument for Water Quality"
execution standardWater Quality COD Online Water Quality Analyzer Sewage Treatment Plant Water Supply Plant
GB11914-1989 "Determination of Chemical Oxygen Demand in Water Quality, Method"
HJ/T 377-2007 "Chemical Oxygen Demand (CODcr) Water Quality Online Automatic Monitoring Instrument"
Performance Characteristics
1. Select valve components: Choose reagent sampling timing, flexible and diverse channels, versatile functions, and advantages such as easy maintenance and high lifespan.
2. It has printing function and can be connected to a printer (optional) to print the measured data in a timely manner.
3. Adopting a 7-inch touch screen and a simple operating interface, it can be easy for users to learn, operate, and maintain.
4. The ultra large data storage capacity enables the preservation of historical data for no less than 5 years (with a measurement interval of 1 time/1 hour), meeting the needs of customers.
5. Automatic liquid leakage alarm function, when a reagent leakage occurs, the instrument will automatically alarm and prompt the user to perform maintenance.
6. The use of optical signal recognition function ensures high accuracy in quantitative analysis.
7. The maintenance of chemical reagents is simplified and convenient, with a monthly replacement of reagents, greatly reducing the maintenance workload for users.
8. Accurate measurement of COD at 35000mg/L chloride ions can be achieved.
9. One click upgrade of USB flash drive makes software updates easier.
Technical SpecificationsWater Quality COD Online Water Quality Analyzer Sewage Treatment Plant Water Supply Plant
Method basis |
Determination of Chemical Oxygen Demand - Dichromate Method |
measurement range |
10-5000 mg/L COD |
accuracy |
When ≥ 100mg/L, not exceeding ± 10%; When<100mg/L, not exceeding ± 8mg/L |
repetitiveness |
When ≥ 100mg/L, not exceeding ± 10%; When it is less than 100mg/L, it should not exceed ± 6mg/L. |
measurement period |
The small measurement cycle is 20 minutes, and according to the actual water sample, the digestion time can be modified arbitrarily within 5-120 minutes |
sampling period |
Time interval (adjustable from 10 to 9999 minutes) and hourly measurement mode |
calibration cycle |
Adjustable at any interval and time from 1 to 99 days |
maintenance cycle |
Usually once a month, about 30 minutes each time |
output |
RS-232, 4-20mA (optional) |
Environmental Requirements |
For indoor environments with adjustable temperature, it is recommended to have a temperature range of+5-28 ℃; Humidity ≤ 90% (non condensing) |
power supply |
AC220±10% V,50±10% Hz,5A |