The LB-RG-Y02 β - ray dust particle monitor is widely used to measure the concentration of particulate matter in ambient air, such as PM10 and PM2.5 (with different sampling and cutting heads available). The overall design of the instrument is reasonable, aesthetically pleasing, easy to use, and easy to maintain.

Product Details

LB-RG-Y02 β - Ray Dust Particle Monitor

Product Introduction

LB-RG-Y02The β - ray particle monitoring instrument uses β - rays and low-energy C14 as the β - ray source. The mass of particles collected on the filter paper is calculated based on the change of β - rays passing through the clean filter paper and the filter paper with particles collected, thus obtaining the concentration of particles in the air. Widely applicable for measuring the concentration of particulate matter in ambient air, such as PM10, PM2.5 (with different sampling and cutting heads available), etc. The overall design of the instrument is reasonable, aesthetically pleasing, easy to use, and easy to maintain.

Performance Characteristics

  1. Modular design, low failure rate, easy maintenance, and strong scalability;
  2. Using high-precision detectors, the measurement is stable, reliable, and the data is accuratemodel
  3. Different cutter heads can be optionally selectedReal time measurement of PM10 and PM2.5 concentrations;
  4. Optional meteorological five parameter monitoring instrument and dot matrixLED display screen, video, etc
  5. adoptThe beta ray absorption method directly measures the mass concentration of particulate matter, which is not affected by seasonal changes, does not require correction, and provides real-time data 24/7;
  6. The instrument adopts the same position detection method of sampling and detection, fundamentally solving the measurement error caused by moving paper tape;
  7. adoptDHS (Dynamic Heating System) heats the sampling inlet gas and has dynamic temperature and humidity compensation function, which meets the standards and can ensure the measurement of semi volatile nitrates and organic compounds;
  8. Adopting imported detectors, the measurement is stable, safe and reliable, and the data is accurate;
  9. The sampling data is automatically memorized, and the current data is automatically saved after a power outage. The instrument can continue sampling after a power outage;
  10. Metal steel material, andIP55 dustproof and waterproof design, able to adapt to complex environments around the clock, can be directly installed for outdoor use, without the need for additional station buildings or outdoor cabinets;
  11. Front and rear double door design, convenient for instrument maintenance and calibration
  12. supportGPRS/4G/wifi and other data remote transmissionMassive data storage capacity, capable of storing up to one year's worth of data. Support one click query of historical data
  13. Chinese touch sensitive color screen, rich display content, user-friendly human-machine interface design, convenient shortcut menu query
  14. It has three sampling modes: whole point, continuous, and real-time

Structural diagram explanation


Technical Specifications

monitoring project

PM10

Principles of Monitoring and Analysis

β - ray method

β - ray source

C-14

Range of particulate matter concentration

0~10000μg/m3How to translate

detection limit

1μg/m3(24H)

Small display unit

0.1μg/m3

Calibration membrane reproducibility

≤± 2% (standard)call, name, say, weighValue)

sampling flow

16.7L/min(Customizable)

flow control

Control error% set valueStability ≤ 2%

ambient temperaturemeasurement

(-30~65)℃

atmospheric pressuremeasurement

(0 to 120) kPa

slope

1±0.15

Cutter performance

Geometric standard deviation of capture efficiency for 50% cutting particle size (Da50):

(10±0.5)µm≤(1.5±0.1);

(2.5±0.2)µm≤(1.2±0.1)

Unmanned working hours

The system runs continuously for 90 days with an effective data rate of over 85%

LB-RG-Y02 β - Ray Dust Particle Monitor

Optional other factors

temperature

Temperature sensor range: -30~70 ℃ accuracy: ± 0.2 ℃

humidity

Humidity sensor range: 0-100% accuracy: ± 3%

wind speed

Range: 0-30m/s, resolution 0.1m/s

wind direction

Range: 8 indication directions

atmospheric pressure

Measurement range: 10-1200mbar

noise

Noise range: 30-130db Accuracy: ± 0.5%

Configuration List

serial number

name/model

quantity

1

Monitor host

1

2

Dynamic heating sampling tube

1

3

PM10cutter

1

4

vacuum pump

1

5

Transmission module

1

6

filter paper

1

7

mounting bracket

1

8

LEDdisplay screen

1

Partial on-site installation drawings

Qingdao Lubo Environmental Protection provides after-sales and technical support for products!