1. The rotor sealing ring made of PEEK material provides excellent solvent resistance to the injector. It can even resist the erosion of alkaline solvents (there are also DuPont polyimide rotor seals)
2. Compact injection markers have been designed inside the device,
3. The special built-in valve diversion system can absorb the pressure shock generated during path switching, effectively preventing damage to the chromatographic column under sudden changes in high pressure.
Switch impact data chart


High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride
-Sample processing procedure-
Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.
-Chromatographic conditions-
Chromatographic column: C18, 4.6 mm*250 mm, Particle size 5 µ m
Mobile phase: Acetonitrile: Acetate buffer solution=25:75
Wavelength: 280nm
Flow rate: 1.0mL/min
Instrument configuration:
Please click to view the image details
|
LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance...... |
|
SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings...... |
|
8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve...... |
|
Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0...... |
|
AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure...... |
|
VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication...... |
Component model VI-11
Maximum pressure (MPa) 35MPa
Material: stainless steel PEEK、 ceramics
External diameter of pipeline 1/16
Internal diameter of pipeline 0.5mm (0.02 ")
Thread size NO.10-32UNF
The sample ring includes 20 μ I (SUS, 1/16 ")
Internal injection marker (1.5 wire length)

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride
-Sample processing procedure-
Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.
-Chromatographic conditions-
Chromatographic column: C18, 4.6 mm*250 mm, Particle size 5 µ m
Mobile phase: Acetonitrile: Acetate buffer solution=25:75
Wavelength: 280nm
Flow rate: 1.0mL/min
Instrument configuration:
Please click to view the image details
|
LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance...... |
|
SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings...... |
|
8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve...... |
|
Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0...... |
|
AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure...... |
|
VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication...... |