Welcome Customer !

Membership

Help

Shanghai Jiapeng Technology Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Ultra micro nucleic acid protein analyzer

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Brief introduction: Nano-600 software operating platform for the $r $n $r $n ultra micro nucleic acid protein analyzer: 7-inch capacitive touch screen, Android system; Wavelength range: 200-800; Colorimetric dish mode (OD600): 600 8nm; sample volume requirement: 0.5-2.0ul; Nano-600 ultra micro nucleic acid protein analyzer optical path: 0.2mm (high concentration measurement); 1.0mm (ordinary concentration measurement); Light source: Xenon flash lamp (with a lifespan of up to 10 years); Detector: ≤ 3nm (FWHM at Hg 546nm).

Product Details

Details introduction:

Product Introduction

The Nano-600 Ultra Trace Nucleic Acid Protein Analyzer (Ultra Trace Spectrophotometer) is a highly reproducible full wavelength spectrophotometer that adopts a dual detection mode of base and colorimetric dish, suitable for sample detection in a wider concentration range. It is easy to operate and can be used not only to measure DNA, RNA purity and concentration, protein concentration, but also for absorbance detection in general substance analysis.

Product Features:

7-inch capacitive touch screen, optimized design APP software

No preheating is required, the detection can be completed in 4 seconds, and the result is directly output as the sample concentration.

If there is no operation within 5 minutes, the light source will automatically turn off to extend its service life.

The software's graphical interface is simple and easy to use, with more intuitive operation and direct export of results.

Only 0.5-2ul of trace sample is needed for purity and concentration measurement, and the sample can be recovered.

For samples with a concentration below 2 ng/ul, fluorescence meter mode can be used, with a low detection limit of up to 0.5 pg/ul

Technical Specifications:

Model number

Nano-600

Software operation platform

7-inch capacitive touch screenAndroid system

wavelength range

200-800; Colorimeter mode(OD600):600±8nm

Sample volume requirements

0.5-2.0ul

optical path

0.2mm (high concentration measurement); 1.0mm (ordinary concentration measurement)

Light source

Xenon flash lamp(The lifespan can reach 10 years

Detector

2048 unit linear CCD array

Wavelength accuracy

1nm

wavelength resolution

≤3nm(FWHM at Hg 546nm)

Accuracy of absorbance

0.003Abs

Absorbance Accuracy

1%(7.332 Abs at 260nm)

Absorption range (equivalent to 10mm)

0.02-100A; Colorimeter mode (oD600 measurement): 0-4A

Testing time

<4S

Scope of nucleic acid testing

2 - 4500 of / UL (dsDNA)

Data output method

USB, SD-RAM card

Sample base material

Quartz fiber and high hardness aluminum