Ultra high performance liquid chromatography prepared for your biomolecule analysis
For the difficulty of passing biomolecules through chromatography, ACQUITY UPLC H-Class is required.
Through biocompatible flow path design, whether your chromatographic mode is reverse phase (RP), ion exchange (IEX), exclusion (SEC), or hydrophilic interaction (HILIC), the ACQUITY UPLC H-Class biological system can maintain the integrity and mobility of macromolecules, resulting in higher sample recovery rates without sample residue.
Ultra high performance liquid chromatographyThe ACQUITY UPLC H-Class biological system provides UPLC advantages - carefully crafted for the analysis of proteins, peptides, nucleic acids, and polysaccharides. Based on the ACQUITY UPLC H-Class system, the ACQUITY UPLC H-Class biological system provides you with more control in biological separation than ever before through the design of a flow-through injection needle, a quaternary solvent delivery system, and AutoBlend Plus technology.
The ACQUITY UPLC H-Class biological system enables you to run more chromatographic modes on a flexible UPLC platform for biopharmaceutical analysis - Results: The system has better chromatographic peak clarity and selectivity, allowing you to perform confident and robust routine qualitative analysis of biomolecules.
Product features:
Multi solvent mixture
The ACQUITY UPLC H-Class biological system provides the greatest flexibility for laboratories with its ability to mix multiple solvents, allowing for binary, ternary, or quaternary gradient operations. In addition, the available 6-position solvent selection valve greatly expands your solvent selection range, allowing you to optimize the method conditions.
Accurate injection, reliable quantification
The circulation needle type sample manager is accurate and precise, with high sample recovery rate and no residue, making the analysis results more reliable and reproducible.
Accurate column temperature control
Different chromatographic column incubators and multi column management systems (switchable between columns) can provide the lowest dispersion and precise temperature management, achieving the highest retention time accuracy. By using methods that can be seamlessly transferred to other laboratories (along the hall or around the world), you can ensure accurate analysis results.
UPLCOptimization detection of separation technology
Without a complete set of ultra-low dispersion detectors designed specifically to maintain peak integrity, any UPLC separation technology would be incomplete. Waters offers the widest range of UPLC optimized detectors - from spectroscopy to mass spectrometry - to meet your diverse detection needs for biological applications.