1. This equipment is divided into three parts: high temperature zone, low temperature zone, and testing zone. The insulation structure and heat storage effect are adopted, and the cold and hot air furnace switching mode is used to introduce it into the crystal testing for cold and hot shock testing;
2. Adopting the original Japanese made microcomputer large LCD (320x240dots) Chinese and English display control system;
3. High program memory capacity, can be set to store 120 sets of programs, with a large cycle setting of 9999 cycles and a large time setting of 999Hrs59Mns for each period of time;
4. Equipped with an RS-232 ℃ communication interface device, it can be connected to a computer for control, editing, recording, and two sets of dynamic points (TIMERSINGALRELAY), making it easy to use;
5. When performing cold and hot shock conditions, the function of zone 2 or zone 3 can be selected;
6. Equipped with fully automatic and high-precision system circuits, any component action can be locked and processed by PL.C;
When there is a mechanical failure, it is equipped with an automatic circuit and warning signal. If the input power is unstable, it has an emergency stop device;
8. Additional equipment (optional)
*Automatic temperature and humidity recorder
*It can meet the slope control of 10 ℃/min, 15 ℃/min, and 20 ℃/min adopted by the factory industry for thermal shock.
Model |
ETST-050 |
ETST-080 |
ETST-108 |
ETST-150 |
ETST-216 |
|
Inner box dimensionsInternal Dim. WxHxD(cm) |
36x35x40 |
50x40x40 |
60x40x45 |
60x50x50 |
60x60x60 |
|
outer box dimensionsExternal Dim. WxHxD(cm) |
126x187x210 |
140x189x210 |
150x194x215 |
150x199x220 |
150x210x230 |
|
High temperature rangeHighTemp. Range |
+60℃~+200℃ |
|||||
Low temperature rangelow Temp. Range |
-10℃~40℃; -10℃~ -60℃; -10℃~ -70℃; |
|||||
temperature rangeTemp. Range |
+60℃~+150℃0℃~ -40℃; -10℃~ -55℃; -10℃~ -65℃ |
|||||
volatilityTemp. Constancy |
+(-)0.5℃ |
|||||
temperature deviationTemp. Constancy |
+(-)2℃ |
|||||
Temperature recovery timeTemp. Recover Time |
≤3 min or ≤5min |
|||||
|
warm-up time Heat-up Time |
℃ |
150 |
150 |
150 |
150 |
150 |
min |
30 |
40 |
40 |
40 |
40 |
|
cooling timePull-down Time |
℃ |
-40 -55 -65 |
-40 -55 -65 |
-40 -55 -65 |
-40 -55 -65 |
-40 -55 -65 |
min |
60 70 80 |
70 80 90 |
80 90 100 |
85 90 105 |
90 100 110 |
|
power supplyPower Source [K.W.] |
AC 3ψ380V 50Hz |
|||||