E-mail
helen.ding@hoy-tech.cn
-
Phone
18049807056
-
Address
Room 511, 333 Jinxiang Road, Pudong New Area, Shanghai
Shanghai Haoyi Scientific Equipment Co., Ltd
helen.ding@hoy-tech.cn
18049807056
Room 511, 333 Jinxiang Road, Pudong New Area, Shanghai
| The testo 106 has the characteristics of fast response and high accuracy. Suitable for fast and easy measurement in restaurants, hotels, industrial kitchens, supermarkets, etc. This compact and practical thermometer can always be at your fingertips. Due to the compact size of the 106 and its very thin and sturdy probe, it is very suitable for measuring small-sized food. |
| Testo 106-T1 Food Centerthermometer Advantages Overview
|
| | |
| Storage temperature | -40.0...70.0 °C |
| Operating temperature | -20.0...50.0 °C |
| Battery Type | Lithium battery (2032) |
| battery life | 250.0 h |
| weight | 80.0 g |
| Specification (LxH) | 34.0 x 215.0 x 19.0 mm |
| probe type(measured value) | range | reaction time | | |
| NTC (Temperature) | -50.0 . .. 230.0 °C | 4.0 - | Accuracy | +/-1.0 °C (-50.0 ... -30.1 °C) +/-0.5 °C (-30.0 ... 99.9 °C) +/-1.0% measurement value (100.0 .. 230.0 °C) |
| | | | resolution | +/-0.1 °C (-50.0 ... 230.0 °C) |
| NTC (Temperature) | -58.0 . .. 450.0 °F | 4.0 - | Accuracy | +/-1.0 °F (-58.0 ... -22.1 °F) +/-0.5 °F (-22.0 ... 212.0 °F) +/-1.0% measurement value (212.1 .. 450.0 °F) |
| | | | resolution | +/-0.1 °F (-58.0 ... 450.0 °F) |
Attachment List - testo 106-T1
| Brief description | annotation | Order Number |
| ISO calibration certificate/temperature | Used for air/immersion probes, with calibration points of -18 ° C; 0 ° C | |
| Frozen Food Diamond | Can be fixed on the fastener | |
| Fasteners, including probe protective caps | Fasteners are used to secure instruments to walls; Probe protection cap protects the probe from injury | |
| Protective soft cover | Waterproof, dustproof, and impact resistant (IP67) | |
| Backup lithium battery | Data will not be lost during battery replacement or charging | |
| ISO calibration certificate/temperature | Used for air/immersion probes, with calibration points of -8 ° C; 0 ° C;+40 ° C | |
| ISO calibration certificate/temperature | Used for air/immersion probes, with a calibration point of+60 ° C | |
| ISO calibration certificate/temperature | Used for air/immersion probes, with a calibration point of 0 ° C | |
| ISO calibration certificate/temperature | Used for air/immersion probes, with a calibration point of -18 ° C | |
| ISO calibration certificate/temperature | Used for air/immersion probes, with calibration points of -18 ° C;+60 ° C | |
| ISO calibration certificate/temperature | Used for air/immersion probes, with calibration points at 0 ° C;+60 ° C |