E-mail
431881753@qq.com
-
Phone
15716165504
-
Address
Dongfang Industrial Park, Qingyang Town, Jiangyin City
Jiangyin Tailan Electronic Instrument Co., Ltd
431881753@qq.com
15716165504
Dongfang Industrial Park, Qingyang Town, Jiangyin City
TM201 shaft vibration transmission protection table
Common models:
TM201-A00-B00-C00-D00-E00-G00
TM201-A00-B01-C00-D00-E00-G00
Monitor the radial vibration of rotating machinery rotors, which can measure shaft vibration, runout, eccentricity, etc.
measurement parameter
Peak to peak value of radial vibration (displacement).
Unit type
Rotating machinery with various sliding bearings. Such as steam turbines, fans, compressors, motors, pumps, etc.
Suitable for retrofitting old units.
Installation requirements
For units with existing eddy current probe systems, simply connect the wires and set alarm points.
output interface
It has 4-20mA active output terminals ("+" and "-" for "4-20mA").
The on-site luminous tube displays the machine's operating status (instrument working status OK, alarm Alert, interlock Danger).
The output terminal SPDT of the isolated two-level alarm relay (6 output terminals of "ALERT" and "DANGER").
On site alarm reset button, remote alarm reset terminal ("RESET")/alarm bypass terminal ("RESET" and "COM").
Can display on-site (TM0200 required) and display vibration values through PLC and DCS.
Suitable for various explosion-proof occasions (requiring explosion-proof isolation barriers).
The buffer output of the original signal is directly connected to the status monitoring instrument ("BUF OUT" coaxial cable interface).
24VDC, 220VAC, or 110VAC power supply, with the 220VAC or 110VAC option being an isolated power supply.
technical indicators
Electrical indicators:
External power supply:
22-30VDC,100mA, Power supply for the upper computer or use TM900;
90-250VAC±20%,50-60Hz,50mA;
Frequency response: (± 3dB):
Standard options: 2.0-5.0KHz;
Low frequency options: 0.5-100Hz.
External eddy current sensor:
Interface terminal:
A/P ": -24V power supply (- VT or POWER); B/S ": Signal (SIG or OUT); COM ": Common terminal (COM or GND).
Sensitivity: 8.0 mV/um (200 mV/mil).
Buffer output (Buf Out):
The output of the original signal.
Output sensitivity: 8.0 mV/um (200 mV/mil);
Voltage output range: 2-18V (non calibrated);
Output impedance: 100 Ω.
Large transmission distance: 300 meters.
Total vibration output (4-20mA):
4-20mA, Active, capable of driving loads up to 750 Ω;
1-5V, Active, with an output impedance of 250 Ω.
Error:
Linear error:<1% FS (least squares, 25)oC);
Temperature coefficient:<0.1% FS/oC;
Alarm point setting (Normal/Set):
Range: 0-100% full scale;
Accuracy: ± 0.1%.
Relay (Alert/Ranger):
Sealing: epoxy resin;
Node capacity: 2A/220V AC or 2A/24V DC; Resistive load;
Node type: Single pole double throw, SPDT;
Output isolation: 1000VDC.
Operating status indicated by the photoelectric tube LED:
Green light: System self-test passed, instrument working normally;
Yellow light: alarm indication;
Red light: Interlock indication.
Alarm reset/alarm side (RESET):
The monitoring table has a built-in alarm reset button;
Remote alarm reset/alarm bypass terminal ("RESET").
physical indicators
Size: Height: 75mm
Weight: 1000 grams.
Environmental indicators:
Working temperature: -350C to+700C;
Storage temperature: -40 ° C0C to+1000C;
Humidity: 95% non solidifying.
TM201-A00-B00-C00-D00-E00-G00 axis vibration table TM201-A00-B00-C00-D00-E00-G00 axis vibration table