1、 Instrument Introduction
CCD-NF Spark Direct Reading SpectrometerIt is a product designed for analyzing and testing non-ferrous metal samplesCCDDirect reading spectrometer, suitable for small and medium-sized casting enterprises, mold enterprises, feed quality inspection and control, metal trade and recycling, automotive industry, etc.
2、 Main features
1Convenient operation, good stability, high reliability, and fast analysis speed;
2Adopting high-resolution technologyCCDFull spectrum detector;
3The instrument has a low detection limit, high analytical precision, and accurate results;
4Easy maintenance and low failure rate;
5The types of analytical materials and elements can be added at any time;
6Reliable quality, specifically designed for non-ferrous metal analysis.
3、 Technical parameters
1Optical system
vMultiple high-performance blocksCCDDetector system, up to16blockCCDdetector
veach pieceCCD 3,648pixel
vHigh performance holographic diffraction grating, grating engraved lines1200 or2700 or3600 article/mm
vTemperature stabilization system
vUsing special materials to cope with drift
vFocal length:500 mm
vSpectral line wavelength:190 - 800 nmDetermined by the selection of diffraction grating. The selection of gratings is determined by the manufacturer based on the analyzed elementsDetermine with the analysis program
vFull optical system automatic tracing
vA sealed optical chamber can avoid interference from dust and light
2Spectral lines
SCNF covers the entire range of elemental analysis and can analyze corresponding elements according to specific needs
vThe optical system includes a solid-state detector that can measure the full spectrum emitted by the sample
vAnd for possible future upgrades, add analysis lines (elements) for convenience
vCan add analysis programs on site
3. Control, electronic acquisition, and data readout system
vElectronic systems have multi-channel integration and data system acquisition functions controlled by microprocessors
vHigh speed 16 bit analog-to-digital converter
vISP mixed signal Flash microcontroller 100MHz
vMultiple connection sources
vHigh speed readout and high-speed USB support for fast data control and processing systems
vUp to 16 CCD modules, to be selected by the manufacturer based on the application situation
4. Spark source
vFully automatic control spark source
vSemiconductor controlled discharge excitation
v1 to 100 A plasma current
vThe discharge parameters are password protected
vSpecial analysis requirements may have different excitation parameters
vSpark light source discharge is stable and not affected by power supply system fluctuations
vThe excitation parameters are calibrated and controlled by the excitation line and analysis program
vSpark sources can have multiple parameter settings
vSpark frequency: 200 to 1000 Hz (controllable)
vSpark duration 10-10000 us (controllable)
5. Spark table
vThe open spark table can analyze and test samples of various shapes weighing up to 20Kg
vThe electrode is easy to disassemble and maintain
vArgon gas blowing spark table, low argon gas consumption
vConvenient sample holder supports quick sample replacement
vAdapter for different samples can meet the needs of various samples (optional)
6. Software: analysis software, calibration software, statistical functions
Calculating the correction curve for each element requires consideration of various matrices (reference lines).
Software functions:
Analysis and calibration software:
Statistical software:
·Comprehensive characteristics:
*32-bit application software
*Font and font size settings
*Date/time format based on Windows settings
*Quick icons for multiple output functions or dialogue operations
*Pull down menu for document operation, filtering, and observation
*Unrestricted number of elements
*The number of sample recognition domains is not limited
*Help file
*Manually convert MS Word files or PDF files (Acrobat Reader)
*Fully automatic control, automatic diagnostic function
database
*Input and output
*Interface between instruments and communication
*File sharing and transmission
*Output files, statistical programs
*Standard output, page setting logo or letterhead function
*Print settings, print preview
*Data printing, work curve printing
* Database management and control
* Multi window support for multitasking work
* Unrestricted viewing of the list of analysis results
* Query function for all database domains
* Analysis editing function
* Send out the sorting results“Didi”sound
* Display format of elements, sizes, and decimal points
* Analysis result copying function
* Unit and decimal point selection for results(Unlimited quantity)
* Manual analysis result input and sample identification
* Optional sample code input using barcode reader
* All sample identification and element domain operations are clear at a glance
* Suitable for querying and outputting all analysis results
* Brand database
* Brand control function
* Brand recognition function
* divideDisplay of brand control in the analysis result list
* Automatic detection of existing brand numbers received
* Exhibition formula editing function
* Custom formula editing
* Numerical statistics function(serial number,addition,average,/relativestandard deviation,,minimum,scope)
*Step macro editing
*Asynchronous macro sorting
*Task server for automatic project or scheduled macro execution
7. Control Station: Computer
Suggested configuration:
Computer: Laptop or desktop (optional) requires installation and confirmation of software compatibility.
CPU Pentium Core 2, 2GB memory
Hard drive>160 GB 7.200 RPM, DVD - CD-DVDRW-CDRW
Display LCD 17 "or 19" TFT
Windows XP operating system
Network, graphics card, USB interface
keyboard, mouse
printer: Color HP Deskjet printer, or equivalent product
8. Size:
Dimension: P55 x L75 x H65 cm
Weight: Approximately 80 Kg
9. Power supply:
110/220V +/- 10%、 Single phase, 50/60 Hz
16 A, < 1.0 KVA