| GC-2014C is a high-performance model independently produced by the Suzhou factory, one of the Shimadzu analytical instrument supply bases. It inherits and integrates the high scalability of the GC-14 series and the ease of operation of GC-2014, providing a complete solution for many fields such as petrochemicals, food analysis, environmental monitoring, etc., with excellent cost-effectiveness. |
|
Flexible and diverse models, customizable configurations
| The GC-2014C gas chromatograph can provide both fully manual and fully automatic flow control models to meet different analysis needs. The fully automatic flow control model adopts the same electronic flow control unit (AFC) as the GC-2010 series and GC-2014 series, achieving high-precision gas flow control, providing constant pressure, constant flow, and Shimadzu's "carrier gas constant line speed" control method, improving the reproducibility of retention time and peak area, and achieving accurate analysis. | ![]() |
| Four injection units and five detectors can be selected based on the target components and analysis objectives. By adopting the method of adding units, various optional components such as injection units, detectors, and automatic samplers can be easily added after the device is purchased. Up to 3 injection units and 4 detectors can be installed simultaneously. 40mm threaded glass columns from Shimadzu GC-7, 9, 12, 14, 15, and 16 series can be used to effectively utilize chromatographic column resources. |
|
| FID-2014 Hydrogen Flame Ionization Detector Suitable for the detection of all organic compounds, equipped with automatic ignition and automatic re ignition functions as standard. The feedback function of automatically cutting off the gas supply when the hydrogen flame is extinguished can be achieved by installing APC or solenoid valve components. There are two types: single FID and dual FID. |
|
| TCD-2014 Thermal Conductivity Detector Suitable for the analysis of organic gases and concentrated organic compounds. TCD-2014 is a semi diffusion detection tank that can reduce pollution and extend the service life of the detection tank. Equipped with an automatic filament protection circuit. |
|
| ECD-2014 Electron Capture Detector Suitable for the analysis of electronegative compounds. Using a detection pool similar to ECD-14, the radiation source can be shared. By improving the insulation of the pool and reducing pollution, high sensitivity can be achieved. |
|
| FPD-2014 flame photometric detector Suitable for the analysis of organic sulfur compounds and organic phosphorus compounds, such as the analysis of residual pesticides and odorous components. Based on FPD-2010, a new nozzle system has been designed to support packed column analysis while ensuring high sensitivity. FPD-2014 has a relatively high upper temperature limit (350 ℃). |
|
| FTD-2014 Flame Thermal Ion Detector Suitable for analyzing organic nitrogen compounds and organic phosphorus compounds, such as pesticide residues. The detector design adopts the FTD-14 structure, which can use the collection poles on FTD-14 and FTD-17 and support packed column analysis. |
|
| FTD-2014C Flame Thermal Ion Detector Suitable for analyzing organic nitrogen compounds and organic phosphorus compounds, such as pesticide residues. A capillary column specific detector using FTD-2010 structure. Replacing the collector does not require the use of tools. Using the optional alkali source regeneration kit can reduce operating costs. |
|