Schneider relay RM22-TA31Product Type Modular Measurement and Control Relay
Relay type control relay
Number of phases in the power grid: 3 phases
Relay name RM22TA
Asymmetric monitoring parameters of relays
Phase fault monitoring
Phase sequence
Adjustable delay type of 0.1... 30 s,+/-10% full-scale value exceeding threshold Tt
Switching capability with VA2000 VA
Measurement range 200... 240 V voltage AC
Schneider relay RM22-TA31Reset time<=1500 ms at maximum voltage
The maximum switch voltage is 250 V AC
Zui small switch current [Imin] 10 mA on... 5 V DC
The maximum switch current is 8 A AC
Rated power supply voltage [Us] 200... 240 V AC
Power supply voltage range 160... 288 V AC
Control voltage limit -20%+20% Un
Power consumption VA10 VA at 240 V AC 60 Hz
Voltage monitoring threshold<100 V AC
Power supply frequency 50... 60 Hz+/-10%
Output contact 2 C/O
Set accuracy to+/-10% of the full scale
Switching threshold error<=0.05% per degree centrality based on permitted ambient air temperature
<= 1 % within the supply voltage range
Delay accuracy setting 10 P
Delay error<=0.05% per degree centrality based on permitted ambient air temperature
<= 1 % within the supply voltage range
Delay 2% fixed optional
Rise delay during power on<=650 ms
Measure the cycle with a true RMS value of 150 ms
Threshold adjustment voltage 2... 20% selected Un
Voltage range 200... 240 V P-P
Asymmetric threshold adjustment 5... 15% selected Un
Repetitive accuracy+/-0.5% for input and measurement circuits
+/-3% time delay
Measurement error<0.05%/° C with temperature variation
<1% with voltage variation across the entire range
Response time<=300 ms
Overvoltage type III complies with IEC 60664-1
III complies with UL 508
Insulation resistance>100 M Ω at 500 V DC in accordance with IEC 60255-27
Installation position: Any position
Wiring Capability: Screw Terminal 2 x 0.5... 2 x 2.5 mm ² - AWG 20... AWG 14, Hardwire Cable without Wire Terminal
Screw terminals 2 x 0.2... 2 x 1.5 mm ² - AWG 24... AWG 16, flexible cable with wire harness terminals
Screw terminal 1 x 0.5... 1 x 3.3 mm ² - AWG 20... AWG 12, hard wire cable without wire terminal
Screw terminal 1 x 0.2... 1 x 2.5 mm ² - AWG 24... AWG 14, flexible cable with wire harness terminal
Tightening torque 0.6... 1 N.m in accordance with IEC 60947-1
Covering material: flame-retardant plastic
LED Status LED Yellow Suitable for Relay ON
LED green is suitable for power on
Installation method: 35mm DIN rail in accordance with EN/IEC 60715
Electrical lifespan of 100000 cycles
Mechanical lifespan of 10000000 cycles
Use category AC-15 in accordance with IEC 60947-5-1
DC-13 complies with IEC 60947-5-1
AC-1 complies with IEC 60947-4-1
DC-1 complies with IEC 60947-4-1
Safe and reliable data MTTFd=388.1 years
B10d = 350000
Contact material is cadmium free
Width 22.5 mm
Product weight 0.09 kg
The transmission standard for electromagnetic compatibility in industrial environments complies with EN/IEC 61000-6-4
The transmission standards for residential, commercial, and light industrial environments comply with EN/IEC 61000-6-3
Exempted from use in industrial environments in accordance with EN/IEC 61000-6-2
Conducted and radiated interference level B complies with CISPR 22
Immunity for residential, commercial and light-industrial environments 符合 EN/IEC 61000-6-1
Anti static interference 6 kV Level 3 contact discharge in accordance with IEC 61000-4-2
Anti static interference 8 kV level 3 air discharge in accordance with IEC 61000-4-2
Radio frequency electromagnetic field radiation immunity test at 10 V/m level 3 in accordance with IEC 61000-4-3
Anti fast transient 4 kV level 4 direct connection in accordance with IEC 61000-4-4
Anti fast transient 2 kV level 4 capacitive coupling in accordance with IEC 61000-4-4
Surge discharge anti-interference 4 kV level 4 common mode in accordance with IEC 61000-4-5
Surge discharge anti-interference 2 kV 4-stage mode complies with IEC 61000-4-5
Conducted and radiated interference Group B 1 complies with CISPR 11
Compliant with standard EN/IEC 60255-1
Product Certification CCC
CE
CSA
GL
UL
RCM
EAC
China RoHS
Storage environment temperature -40... 70 ° C
Environmental temperature -20... 50 ° C at... 60 Hz
-20... 60 ° C on... 50 Hz AC/DC
Relative humidity 93... 97% above 25... 55 ° C in accordance with IEC 60068-2-30
Anti vibration 0.075 mm (f=10... 58.1 Hz) (not in operation) in accordance with IEC 60068-2-6
1 gn (f = 10...58.1 Hz) (not in operation) 符合 IEC 60068-2-6
0.035 mm (f=58.1... 150 Hz) (during operation) in accordance with IEC 60068-2-6
0.5 gn (f=58.1... 150 Hz) (during operation) in accordance with IEC 60068-2-6
Technical Features
The Schneider sensor industry is at a critical stage of development from traditional to new sensors, reflecting the overall trend of miniaturization, multifunctionality, digitization, intelligence, systematization, and networking of new sensors. Sensor technology has undergone years of development, and its development can be roughly divided into three generations:
*Dai is a structural sensor that utilizes changes in structural parameters to sense and convert signals.
The second generation is a solid-state sensor developed in the 1970s, which is composed of solid components such as semiconductors, dielectrics, and magnetic materials, and is made using certain properties of the materials. For example, by utilizing the thermoelectric effect, Hall effect, and photosensitive effect, thermocouple sensors, Hall sensors, and photosensitive sensors are respectively made.
The third generation of sensors is a newly developed intelligent sensor that combines microcomputer technology with detection technology, giving the sensor a certain degree of artificial intelligence.