E-mail
2355324315@qq.com
-
Phone
13701838729
-
Address
1399 Haining Road, Shanghai.
Shanghai Boyang Pump Factory
2355324315@qq.com
13701838729
1399 Haining Road, Shanghai.

The Gongbo SZ series water ring vacuum pump and compressor are used to suction or compress air and other non corrosive, insoluble, and solid particle free gases, in order to create a vacuum and pressure in a closed container. But inhaling gas allows for the mixing of a small amount of liquid.
Due to the isothermal compression of gas during the working process, it is less likely to cause danger when compressing and suctioning flammable and explosive gases. So its application is more extensive.
The Gongbo brand SZ series water ring vacuum pump is widely used in the fields of machinery, petrochemicals, pharmaceuticals, food, sugar industry, and electronics.
| model | Large vacuum suction capacity (m3/min) |
Large displacement of compressor (m3/min) |
Motor power (kw) |
Speed (r/min) | Water consumption (L/min) | 大真空度(%) | High pressure (MPa) | weight (including motor) Weight |
|||||||||
| True emptiness is | When the pressure is (MPa) | vacuum pump |
compressor |
||||||||||||||
| 0 | 40% | 60% | 80% | 90% | 0 | 0.05 | 0.08 | 0.1 | 0.15 | ||||||||
| SZ-1 | 1.5 | 0.64 | 0.4 | 0.12 | - | 1.5 | 1 | - | - | - | 4 | 5.5 | 1440 | 10 | 84 | 0.10 | 310 |
| SZ-2 | 3.4 | 1.65 | 0.95 | 0.25 | - | 3.4 | 2.6 | 2 | 1.5 | - | 7.5 | 11 | 1440 | 30 | 87 | 0.14 | 380 |
| SZ-3 | 11.5 | 6.8 | 3.6 | 1.5 | 0.5 | 11.5 | 9.2 | 8.5 | 7.5 | 3.5 | 22 | 37 | 980 | 70 | 92 | 0.21 | 1300 |
| SZ-4 | 27 | 17.6 | 11 | 3 | 1 | 27 | 26 | 20 | 16 | 9.5 | 75 | 90 | 740 | 100 | 93 | 0.21 | 2000 |
1. The suction and exhaust volume of vacuum degree from 40% to 90% or pressure from 0.05MPa to 0.15MPa varies with the size of the water supply, the gap size between the impeller and the side cover, and the gap size between the impeller and the side cover. Especially when the flow rate is small, if the adjustment is not accurate, it is more likely to cause a smaller deviation
2. The values in the table are obtained under the following conditions: ① Water temperature of 15 ℃; ② Air temperature is 20 ℃; ③ Gas relative temperature 70%; ④ Atmospheric pressure 0.1013MPa
3. The performance deviation within the table shall not exceed 5%