SMC vacuum generatorZK2A10J5CLA-06
ZK2 series vacuum unit vacuum generator system
● Add a high noise cancelling muffler
Low noise: 46dB (A)
Inhalation flow rate: approximately 20% increase
Corresponding to vacuum generator system and vacuum pump system
Due to the presence of energy-saving digital pressure switches for vacuum applications
When reaching the vacuum state, the gas supply can be cut off: the gas consumption is reduced by 90%
Due to the efficient vacuum generator, the suction flow rate increases by 50%
Reduce gas consumption by 30%
(Compared to other single-stage vacuum generators in SMC)
SMC vacuum generatorZK2A10J5CLA-06
| field description | Field value | Value Description |
|---|---|---|
| System, main specifications | A | Single unit muffler exhaust |
| Orifice diameter | 10 | Φ1.0 |
| Supply valve, destroy valve combination | J | Supply valve: N.C; Destructive valve: None |
| rated voltage | 5 | DC24V |
| Pressure sensor, vacuum pressure switch specifications | C | Digital pressure switch for vacuum; Pressure range 0~-101; PNP2 output with unit switching function |
| Specification for pressure switch sockets for supply valves, rupture valves, and vacuum applications | L | Supply valve, destructive valve socket: L-shaped socket with socket wire; Pressure switch/sensor with socket wire |
| Vacuum (V) port | 06 | Φ6 |
| Option A | - | No options available |
| Option B | - | No options available |
| Optional option c | - | No options available |
Confirm specifications. The products listed on this sample are only designed for use in compressed air systems (including vacuum). If the pressure and temperature exceed the specifications of this product, it may cause poor operation and damage. Please do not use it. When using fluids other than compressed air (including vacuum), please contact our company. We cannot guarantee any damages caused by usage beyond the specified range.
To deal with accidents caused by power outages or gas source failures, resulting in a decrease in vacuum pressure, and to carry out safety design. Vacuum pressure drops, suction cup suction is insufficient, and workpieces fall off during transportation, which can cause damage to human body and equipment. Comprehensive safety measures such as preventing falling should be designed.
Vacuum switching valves, vacuum breaking valves, and other vacuum piping should use products with vacuum specifications. If vacuum piping is not set up using components with vacuum specifications, air leakage or poor operation may occur. Please make sure to use vacuum specification components.
A vacuum generator with suitable suction flow rate should be selected. If there is a leakage from the workpiece or piping, and the suction flow is insufficient, it will result in poor suction. In situations where the piping is long or thick, an increase in piping volume results in a slower suction response time. Please refer to the technical documentation to select a vacuum generator suitable for suction flow rate.
If the suction flow rate is too high, it will be difficult to set the vacuum switch. For small workpieces a few millimeters in size, if a vacuum generator with excessive suction flow rate is selected and the difference between the vacuum pressure when not suctioned is too small, it will make it difficult to set the vacuum pressure switch. Therefore, a suitable vacuum generator should be selected.
When one vacuum generator drives two or more suction cups, once the workpiece on one suction cup falls off, the workpieces on the other suction cups will also fall off. If a workpiece on one suction cup falls off, the vacuum pressure decreases and the workpieces on other suction cups also fall off.