SF low-voltage switchgear

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview: The SD series universal soft start control cabinet is a single motor control device that uses intelligent soft starters as the main control components and is equipped with fast fuses, main circuit breakers, bypass contactors, and motor thermal relays. It can achieve multiple protections

Product Details

※ Overview
The SD series universal soft start control cabinet is an intelligent typeSoft starterA single motor control device that integrates the main control components with fast fuses, main circuit breakers, bypass contactors, and motor thermal relays, and can achieve multiple protections.
※ Control function
The control device (with an optional all digital soft starter) is equipped with start and stop buttons, as well as operation, stop, and fault indicators. The device is equipped with remote control contacts, which include start and stop input contacts, operation indication output contacts, and fault output contacts (all passive relay contacts). It has functions of short circuit protection, overload protection, overheating protection, and phase failure protection.

※ Design selection


Starter model

rated current
(A)

Adaptive motor power (kW)

Rated limit short circuit
Current (KA)

Adapt to fast melting
Instrument specification (A)

Optional external current
Transformer specifications

Standard load

Heavy load

SD017

17

7.5

5.5

50

50

75A/5A

SD022

22

11

7.5

50

63

75A/5A

SD032

32

15

11

50

100

75A/5A

SD038

38

18.5

15

50

100

75A/5A

SD047

47

22

18.5

50

125

75A/5A

SD062

62

30

22

50

200

200A/5A

SD075

75

37

30

50

200

200A/5A

SD088

88

45

37

50

250

200A/5A

SD110

110

55

45

50

315

200A/5A

SD140

140

75

55

50

400

200A/5A

SD170

170

90

75

50

400

500A/5A

SD210

210

110

90

50

700

500A/5A

SD250

250

132

110

50

700

500A/5A

SD320

320

160

132

50

1000

500A/5A

SD370

370

185

160

50

1000

500A/5A

SD410

410

220

185

50

1250

1000A/5A

SD480

480

250

220

50

1250

1000A/5A

SD590

590

315

250

85

1800

1000A/5A

SD660

660

355

315

85

1800

1000A/5A

SD790

790

400

355

85

2500

1000A/5A

technical indicators

meet the standard

GB14048.6-1998,IEC947-4-2

Rated working voltage (Ue)

AC380V, +15%, -20%

Rated working current (Ie)

17A ~ 790A, There are a total of 20 rated values, as shown in the selection comparison table

Adapt motor power

7.5kW ~ 400kW, Refer to the selection comparison table

Usage category

AC-53B control cage motor, short circuit (bypass) controller during operation

Overcurrent characteristics

3x current, withstand time 12s, cut-off time 600s

rated frequency

50±2Hz

Rated working system S

20 operation cycles per hour

Design form

Type 1

Rated insulation voltage (Ui)

660V

Rated impulse withstand voltage (Uimp)

2500V

Protection level

IP20

pollution level

3

Rated limit short-circuit current

Refer to the selection comparison table

Rated control power supply voltage Us

AC220V, +20%, -30%

Rated control power frequency

50±2Hz

Control power consumption

≤5W

Overvoltage detection

+20% of rated operating voltage

Undervoltage detection

-35% of rated operating voltage

Overcurrent detection

4x to 15x (adjustable panel), continuous alarm for 0.1s

overload protection

Equivalent overload relay trip levels 10A, 10, 20, 30 (panel adjustable)

Temperature over limit detection

Heat sink temperature 60 ℃

communication interface

RS-485 standard interface

通信速率

Optional 2400bps, 4800bps, 9600bps, 19200bps

ambient temperature

Work: -20~+50 ℃,? Storage: -40~+70 ℃

ambient humidity

≤ 95% without condensation or dripping

working height

No capacity reduction within an altitude of 1000m;
The rated current decreases by 1%/100m above an altitude of 1000m

cooling method

Natural air cooling