OneSCRC100-LB12 type reactive power compensation controllerProduct Overview
The SCRC100-LB12 reactive power compensation controller is a new type of distribution measurement and control equipment that integrates data acquisition, communication, reactive power compensation, and other functions. It is suitable for reactive power compensation control in AC 0.4KV, 50Hz low-voltage distribution systems. The SCRC600-LB12 reactive power compensation controller is based on a high-speed digital signal processor and uses AC sampling. It has functions such as sampling calculation, reactive power compensation, harmonic analysis, and communication, and supports RS485 communication port and MODBUS protocol.
IISCRC100-LB12 type reactive power compensation controllerTechnical Specifications
1. Working environment conditions:
Environmental temperature: -40 ℃ to+85 ℃;
Humidity conditions: 20% to 90% at 40 ℃;
Altitude: The altitude of the installation site shall not exceed 2500m.
Environmental conditions: There is no explosion hazard in the surrounding medium, no gas that can damage insulation or corrode metals, no conductive dust, and the installation site cannot vibrate violently.
2. Basic parameters:
1) Working power supply: AC 220V ± 20%; 50Hz±5Hz
2) Sampling voltage: AC 380V ± 20%; 50Hz±5Hz
3) Sampling current: 0-5A
4) Local power consumption: ≤ 12W
3. Technical parameters:
Switching delay: 0-600s
Output contact: 24 channels
Communication interface: RS485
Target power factor: 0.9-0.99
Measurement accuracy:
Voltage: ± 0.5%
Current: ± 0.5%
Power factor: ± 1.0%
Active power: ± 1.0%
Reactive power: ± 1.0%
Frequency: ± 0.01Hz
3、 Main technical features
1. Real time display of power grid voltage, current, power factor, active power, reactive power, apparent power, total harmonic distortion rate of voltage, total harmonic distortion rate of current, system frequency, switching status of distribution container group, and content rate of 3rd to 21st odd harmonics.
2. Current conversion ratio, overvoltage protection, undervoltage protection, voltage total harmonic distortion rate exceeding limit, current total harmonic distortion rate exceeding limit, target power factor, input threshold, input delay, cut-off delay, re input delay, strong switching delay, and switching sequence can be set.
3. The sampled physical quantity is reactive power, no switching oscillation, and no compensation dead zone;
4. There are two operating modes: manual switching and automatic switching;
5. Control 24 output contacts, each with DC12V.
6. RS485 communication, communication protocol MODBUS, baud rate: 9600bps
7. Overvoltage protection, harmonic distortion rate over limit protection, and power-off data protection.
8. Self check and reset function, ensuring that the output circuit is in a disconnected state after each power on. If the sampling current is less than 0.1A, it will automatically lock.