Rozhnik TP31-IR infrared thermometer for non-contact temperature measurement

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Using TP31-IR, non-contact surface temperature measurement can be quickly performed. Due to its adjustable emissivity level and dual lasers, it can accurately measure the surface of various materials. The focal distance of the optical device lens from the beam exit opening is 150 mm (TP31-IR121) or 762

Product Details

Using TP31-IR, non-contact surface temperature measurement can be quickly performed. Due to its adjustable emissivity level and dual lasers, it can accurately measure the surface of various materials. The focal distance of the optical device lens from the beam exit opening is 150 mm (TP31-IR121) or 762 mm (TP31-IR301). The diameter of the measuring point is 12.5mm, which is 25.4mm, and the ratio of D: S is 12:1 or 30:1. The size of the measurement point corresponds to 90% of the measured energy. Therefore, TP31-IR301 allows for accurate measurement of small surfaces from further distances.

Features:

12: 1 (-50... 650 ° C) or 30:1 optical component (-50... 1000 ° C)

Dual beam laser sight

Automatic data saving

The unit can be switched between ° C and ° F

The emissivity level can be adjusted between 0.1 and 1.0

MAX temperature display

glowing display

Automatic range selection and display resolution of 0.1 ° C or 0.1 ° F

Can activate trigger lock

Free selection of lower and upper limit alarm restrictions

Technical Specifications:

precision -50...20 °C (-58...68 °F): ±2.5 °C (±4.5 °F)
20... 300 ° C (68... 572 ° F): ± 1.0% reading ± 1.0 ° C (± 1.0% of reading ± 1.8 ° F)
>300 ° C (>572 ° F): ± 1.5% reading
scope of work 0...50 °C (32...122 °F) 10…90 %RH
Ratio D: S TP31-IR121: 12:1
TP31-IR301: 30:1
repetitiveness -50...20 °C (-58...68 °F): ±1.3 °C (±2.3 °F)
>20 ° C (>68 ° F): ± 0.5% or ± 0.5 ° C for reading (± 0.5% or ± 0.9 ° F for reading)
Power supply/power consumption 9 V battery (NEDA 1604A or IEC 6LR61)
response time 150 ms
Sensor sensitivity 8...14 μm
Diode laser Output power<1 MW wavelength 630 to 670=''>1>
Laser product grade II
display resolution 0.1 °C/°F @ T < 1000=''>
1 °F @ T > 1000 °F
emissivity 0.10 . 1.00 (0.01 step)
Storage and Transportation Conditions -10...60 °C (14...140 °F) <80>80>
size 107x153x46mm