The UDE-507 series RF admittance level switch is a novel level measuring instrument that uses * RF admittance technology to overcome the defect of capacitive level meters that cannot eliminate the influence of conductive hanging materials. The instrument has reliable operation and can resist the influence of heavy hanging material layers, making it suitable for almost all industrial sites. The instrument also has easy installation and maintenance free features. Characteristics such as low price. Instruments are widely used in industrial fields such as petroleum, chemical, metallurgical, pharmaceutical, power, food, paper, etc ....

Product Details

RF admittance level switch

Product Features:

Capable of measuring liquid and material levels, meeting the measurement requirements of different temperature and pressure media, with high measurement temperatures up to 800 ° C and high pressures up to 5MPa, and can be applied in harsh environments such as corrosion and impact. Specially designed to withstand a pressure of 10MPa

Anti hanging material: The circuit design and sensing structure of * ensure that its measurement is not affected by sensor scraping and does not require regular cleaning, avoiding false measurements

Maintenance free: There are no movable parts during the measurement process, and there is no mechanical damage issue, so no maintenance is required.

Anti interference: contact measurement, strong resistance, can overcome the influence of steam, foam and agitation on measurement.
Accurate and reliable: Diversified measurement quantities make measurements more accurate, measurement is not affected by environmental changes, high stability, and long service life

Typical applications:

Conductive and insulating liquids - chemical, oilfield, water and sewage treatment

Conductive and insulating pastes - papermaking, pharmaceuticals, water and wastewater treatment

Powder: ash, powder - power plants, metallurgy, cement

● Particles: coal, grain - power plants, metallurgy, grain

RF admittance level switch

Selection parameters:

Power supply: 24VDC, 5W; 220VAC, 50/60Hz; 110VAC, 50/60Hz;

Output: DPDT relay (double pole double throw)

Contact capacity: 117/220V AC, 5A non inductive, 3A inductive

Environmental temperature: -40~63 ℃

Output insulation: signal line to sensor greater than 1000V

Response time: Standard: 0.2 seconds, optional: adjustable from 0 to 90 seconds

Electrostatic spark protection: standard: 10A; additional protector: 100A

Electrical interface: M20 × 1.5

Explosion proof rating: (North American standard) Cables and sensing components are inherently safe in all groups of Zone 1 and Zone 2.

The circuit units inside the explosion-proof enclosure are explosion-proof in all groups of Zone 1 and Zone 2.

Intrinsic safety type: ExiaICT4~T6

Explosion proof type: ExdIIBT4

Shell protection: FM

Certified to meet the explosion-proof requirements of NEMA1~5, 4X, 12, and 13 (IP65)

Certification: FM, CSA, CE MARK

Sensor installation: Standard: 3/4 '' NPT thread

Selection Table:

Product structure: