Quasi dual beam UV visible spectrophotometer
TU-1901 Host Part Operation Interface
DNAProtein measurement scheme one 260nm 280nm measurement scheme two 260nm 230nm
The automatic measurement of DNA/protein mainly involves measuring the absorbance at the points of 260nm/280nm/230nm/320nm, and obtaining the concentration of DNA and protein according to the calculation formula.

Quantitative measurement - By inputting known X and B values, the content of unknown samples can be measured
quantitative measurement
For quantitative analysis of samples, multiple standard samples (two or more) can be used to establish absorbance concentration curves at different wavelengths, and the unknown sample concentration can be obtained from these curves.

Multi wavelength testing - refers to the measurement of absorbance/transmittance of a sample at multiple wavelengths

Spectral scanning - the sample needs to draw a large absorption peak within a certain wavelength range,
Automatically provide peaks and valleys of unknown samples (qualitative analysis)


Time Scan——Dynamics measurement, also known as time measurement, refers to the process where users set wavelength points based on their own samples and scan the sample solution within a certain scanning time range at regular intervals
Measure absorbance or transmittance at scanning intervals, or convert absorbance to concentration by inputting concentration factors.
Can perform time scanning to set single wavelength absorbance or transmittance, and establish absorbance (or transmittance) - time curve

UVSpectral Analyst (PC Workstation Introduction)
Three dimensional spectrum (3D map)
Audit tracking GMP management

All test results can be directly sent via Bluetooth, email, or other means.
PDFTest results

Instrument technical specifications
Product Model |
TU-1901 |
|
|
optical system |
1600Strip/mm CT type optical path alignmentDual beamUV visible spectrophotometer |
||
Narrow slit bandwidth |
1.0 nm |
||
wavelength range |
190—1100 nm |
||
wavelength resolution |
0.1 nmOptical focal length 350mm |
||
The data shows |
8Inch new generation true color touch LCD display screen |
|
|
Wavelength accuracy |
± 0.1nm (@ 656.1nmD2, ± 0.3nm (full wavelength range) measured ± 0.2nm |
||
wavelength repeatability |
≤0.2nm |
||
Scanning speed rate |
High, medium, and low options available at 4100nm/min |
||
stray light |
≤0.02%T(220nm Nal;360nm NaNO2) |
||
Luminous range |
0-200%T,-0.301-6.0A,-9999-9999C |
||
Photometric accuracy |
±0.002A(0-0.5A), ±0.3%T(0-100%T) |
||
Photometric repeatability |
±0.001A(0-0.5A), ±0.15%T(0-100%T) |
||
baseline flatness |
±0.0005A |
||
Baseline drift |
±0.003A/h |
||
Photometric noise |
± 0.0003A (500nm, 0A, 2nm spectral bandwidth) |
||
data output |
UDisk data output,Bluetooth, wireless network, |
||
Language mode |
bilingual Automatic switching between Chinese and English |
||
power supply |
AC 90-240V 150W |
||
detector |
Imported photomultiplier tube |
||
weight |
25kilogram |
||
size |
600*500*210mm |
||
Instrument Configuration Table
serial number |
name |
quantity |
remark |
1 |
accurateDual beam UV visible spectrophotometerhost |
One unit |
|
2 |
power cord |
One root |
|
3 |
High performance paired quartz colorimetric dish 1cm (two boxes) |
Four of them |
|
4 |
High performance paired glass colorimetric dish 1cm (one box) |
Four of them |
|
5 |
Data package (operation manual, warranty card, product qualification certificate) |
a set |
|
6 |
TU-1901software package |
a set |
|
7 |
TU-1901 Win10Spectral analysis software |
a set |
advantage |
8 |
TU-1901 Win10Spectral Analyst PC Workstation |
a set |
advantage |
9 |
USBconnecting wire |
|
|
10 |
High precision micro colorimetric dish holder (1cm) standard |
a set |
|
Optional selection | |||
1 |
Automatic eight rack |
a set |
optional |