Large flat panel tester

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Professional testing of solid samples with specifications ranging from 1.0mm to 500mm. Thickness: 0.01-100mm. Solid, film, beer bottle, architectural glass, touch screen industry, textile, jewelry appraisal, vacuum coating, and determination of optical properties of single-layer and multi-layer window glass components. The measurement range is 190-1100nm; Accurate transmittance; #177; 0.3% T wavelength accuracy #177; 0.3nm; stray light ≤ 0.01% T slit variable 1 two four 5. Instrument grade GB/T26798-2011 Grade II $r $n self calibration upon startup; Connected PC operating terminal

Product Details

Large flat panel tester principle

The analysis principle of the flat plate testing instrument is to use the selective absorption phenomenon of substances to different wavelengths of light for qualitative and quantitative analysis of substances. By analyzing the absorption spectrum, the structure and chemical composition of substances can be determined. Using a prism or grating to separate monochromatic light, the monochromatic light is continuously passed through a solution in sequence, and the absorption of each wavelength by the solution is measured to obtain the absorption spectrum curve.

This instrument operates based on the principle of relative measurement, which involves selecting a solvent (distilled water, air, or sample) as the reference solution and setting its transmittance (i.e., transmittance)T)For100%The transmittance of the tested sample is obtained relative to the reference solution. Transmittance (transmittance)T)There is a certain functional relationship between the changes in the concentration of the measured substance, and within a certain range, it conforms to the Lambert Beer law.

among whichTTransmittance ratio( Transmittance rate

A AbsorbanceC Solution concentrationK The absorbance coefficient of the solutionL The length of the liquid layer in the optical path

I The intensity of light passing through the test sample and shining onto the photoelectric converter

Io The intensity of light passing through the reference test sample and shining onto the photoelectric converter

Our company producesLarge flat panel testerIt is based on this principle, combined with modern precision optics andsuperA new generation of advanced spectrophotometers with advanced capabilities, developed through research and development in microelectronics and other fields.

1.2purpose

It can be used for scientific research in disciplines such as physics, chemistry, medicine, biology, pharmacology, geology, etc. It is widely applied in chemical engineering, pharmaceuticals, biochemistry, metallurgy, light industry, materials, environmental protection, medical laboratory testingProfessional testing of solid samples, with specifications ranging from 1.0mm to 500mm and thicknesses of 0.01-100mm, including solids, films, beer bottles, architectural glass, touch screen industry, textile, jewelry appraisal, vacuum coating, and the determination of optical properties of single-layer and multi-layer window glass components,It is a conventional laboratory instrument,.

1.3feature

The large flat plate tester produced by our company has the following characteristics:

Adopting a low stray light, high-resolution dual beam optical path structure monochromator, the instrument has good stability, reproducibility, and accuracyThe measurement reading.

There are two types of slits: fixed slits and variable slits. The width of the fixed slit is fixed2nm,The width of the variable slit is0.5nmThe1nmThe2nmThe4nmand5nmTo meet the requirements of different analysis and testing projects for monochromatic bandwidth.

adoptZ XMicrocomputer technology not only enables instruments to automatically set 0% Tand100%TIt has control functions and various concentration calculation and data processing methods, as well as special functions to prevent user operation errors, ensuring worry free use.

Scientific design and the application of new technologies organically combine optical, mechanical, electrical, and microcomputer technologies to make the stability indicators of instruments close to or reach the import level.

adoptAndroidThe system, in terms of display, can not only display data but also graphs. With rich built-in software, it can complete quantitative analysis, qualitative analysis, dynamics, and multi wavelength analysis,DNA/ProteinWaiting for testing, coupled with powerful storage capabilities, and implementationWIFIConnect to the network and implement the email sending light function. It is possible to complete all testing, analysis, and data output without connecting to a computer.

The instrument can also be optionally installedWindowsOur company's user application software running on the operating platform enables the instrument to have greater functionality.

Instrument configuration

serial number

name

quantity

remark

1

film Flat film tester

One unit

2

Spectral analysis software transmission

a set

3

One power cord

One root

4

PCworkstation

a set