Portable Brightness Meter

NegotiableUpdate on 02/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Luminance Meter LS/Portable Luminance Meter: LS-100 Single Mirror Reflective Luminance Meter, used to measure the reflectivity of light sources and object surfaces LS-110 is suitable for measuring the brightness of small areas, and the measured values can be used for different purposes
Product Details

LS portable brightness meter:

LS-100 single mirror reflective luminance meter, used for measuring the reflectivity of light sources and object surfaces

LS-110 is suitable for measuring the brightness of small areas. The measured values can be used for different purposes

There are three options available: "instantaneous brightness value", "peak brightness value", and "brightness ratio"

model

Brightness meterLS-100

Brightness meterLS-110

type

Point type single mirror reflective non-contact measurement digital brightness meterUsed for measuring light sources and surface light sources

Measure the angle

1/3°

optical system

85mm f/2.8camera lens; Single mirror reflective observation system

Observer field of view

focusing distance

1014mmTo infinity

Zui small measurement range

Ø14.4mm

Ø4.8mm

Photosensitive component

Silicon photodiode

Relative spectral response

ForCIESpectral illuminance sensitivityThe deviationf1±8%within

reaction time

FASTSampling time:0.1sDisplay time:0.8to1.0s
SLOW
Sampling time:0.4s Display time:1.4to1.6s

luminance unit

cd/m2orfL (Can be selected at any time

measurement range

FAST0.001to299,900cd/m2(0.001to87,530fL)
SLOW
0.001to49,990cd/m2(0.001to14,590fL)

FAST0.01to999,900cd/m2(0.01to291,800fL)
SLOW
0.01to499,900cd/m2(0.01to145,900fL)

precision

0.001to0.999cd/m2
±2%±2
Display numerical values
1.000cd/m2
Or above:
±2%±1
Display numerical values
Measurement object:Alight source

0.01to9.99cd/m2
±2%±2
Display numerical values
10.00cd/m2
Or above:
±2%±1
Display numerical values
Measurement object:Alight source

repetitiveness

0.001to0.999cd/m2
±0.2%±2
Display numerical values
1.000cd/m2
Or above:
±0.2%±1
Display numerical values
Measurement object:Alight source

0.01to9.99cd/m2
±0.2%±2
Display numerical values
10.00cd/m2
Or above:
±0.2%±1
Display numerical values
Measurement object:Alight source

Correction mode

Minolta Standard/user-selection criteriaCan be selected at any time

Color compensation coefficient

Input numerical values; Scope:0.001to9.999

Reference brightness

1Group; By measuring input or numerical input

Measurement Mode

Brightness; Illuminance ratio; Zui high illumination or illumination ratio

display

External instructions:4Bit valueLCDDisplay and additional instructions
Indicator inside the viewfinder:4Bit value display with background lighting

data output

RS-232C

external control

Measurement can be controlled by the data output channel

power supply

1piece9Vbattery Alternatively, a data processor can be purchased separatelyDP-10provide power supply

volume

79 x 208 x 150mm

weight

850g (Battery not included

Standard Accessories

Lens cover, eyepiece cover, neutral gray filter for eye contact9VBattery, storage box