PSS MCX gel column

NegotiableUpdate on 04/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The PSS MCXTM column is suitable for analyzing technical products and food/beverage chromatography columns, and is very stable to high pressure and any pH value.

Product Details

PSS MCXTMThe column is suitable for analyzing technical products and food/beverage chromatography columns, and is very stable to high pressure and any pH value.
Key Features
l Organic modifiers are not required for the analysis of anionic polymers in aqueous phase
l Used for analysis resolution of oligosaccharides*
l Durable and stable against high voltage
l Reliable analysis results for fruit acids and alcohols
PSS MCXTMThe application scope of columns
Ø GPC
l Neutral water-soluble polymers: sugars, starch and its glucan derivatives, branched starch, cellulose, modified cellulose
l Anionic water-soluble polymers: polyacrylic acid, poly (methyl methacrylate), poly (sulfonated styrene), carboxymethyl cellulose, polyaspartic acid, hyaluronic acid, heparin, lignin, sulfonated lignin, humus (buffer solution without organic modifiers)
Special reminder: Not applicable to ammonium compounds and cationic polymers!
Ø HPLC
l Fruit acid, alcohol, sugar, gum

image8.1Analysis results of apple juice, gum, sugar, and alcoholInjection: Colloid6mlDifferent types of sugar10ml,ethanol17mlAnalysis conditions:PSS MCXTMpillar1000, 5µm, 8×300mm.1.0ml/min.20,mobile phase0.05%NaNO3Water solution, detectorRI
image8.2Analysis results of oligosaccharides (hydrolyzed pectin)
Analysis conditions:3×PSS MCXTMpillar1,0005μm, 8×300mm,0.5ml/min,80Mobile phase:0.05%NaNO3Aqueous solution,detectorRI
image8.3Analysis results of different fruit acids and alcohols
Analysis conditions:PSS MCXTMpillar1005μm, 8×300mm,0.5ml/min,80
Mobile phase:0.05MH2SO4Water solution, detectorRI
image8.4Analysis results of sulfonated ligninAnalysis conditions:1×PSS MCXTMpillar1000Å,10μm,1×PSS MCXTMpillar 105Å,10μm, 8×300mm,1ml/min,20,mobile phase0.07MNa2HPO4aqueous solution,detectionRefractometer (black),Light scattering (red)
Table 8 PSS MCXTMPerformance indicators of columns

Aperture (Å)
Particle size (μ m)
Theoretical number of trays (N/m)*
Pressure resistance (bar)
Typical back pressure/30cm (bar)**
100
5
>25,000
200
40
500
5
>25,000
200
40
1000
5
>25,000
200
40
1000
10
>20,000
200
25
105
10
>10,000
100
25
106
10
>10,000
80
25
107
20
>5,000
60
7
*Calculated from β - glucan P1 (glucose) at a concentration of 1.0ml/min, 20
**Analysis column (8 × 300cm), 20 ℃, flow rate 1.0ml/min, mobile phase 0.05% NaNO3aqueous solution
*The working temperature ranges from 20 ℃ to 90 ℃. The maximum flow rate should not exceed 2.5ml/min. Raising the working temperature from 20 ℃ to 80 ℃ and/or reducing the flow rate from 1.0ml/min to 0.5ml/min can increase the theoretical number of trays to 60000m/m (for several 5 μ m PSS MCX with pore sizes of 100500 and 1000 Å, respectively)TMIn terms of pillars.
Figure 8.5 PSS MCXTMSeparation range of columns
Figure 8.6 PSS MCXTMCorrection curve of column
Standard branched starch, PSS MCXTM8×300mm,
Flow rate 1.0ml/min, temperature 20
Mobile phase 0.05% NaNO3Water solution, RI detector
PSS MCXTMCharacteristics of columns
l Multipurpose: Suitable for buffering aqueous solutions and/or water/organic mixed systems. PSS MCXTMWhen used for water-based GPC analysis, there is no need to add organic modifiers (such as for analyzing lignin, humus, aromatic sulfonic acids). PSS MCXTMColumns can be used for GPC or HPLC according to different operating conditions. Neutral or alkaline conditions are typical for GPC separation, while low concentration strong acid environments are typical for HPLC separation, such as separating carboxylic acids in nutritional technology.
l Chemical stability: PSS MCXTMThe column is stable to any pH value and buffer solution. When a large amount of organic modifiers such as methanol or acetonitrile are added, it also has good performance. Even after use in high pH environments (such as in the wood and paper industries), it still maintains good column performance.

Durability: It has a longer service life than similar products on the market. in80and1.0ml/minUnder the operating conditions of flow rate, the column performance can still be maintained. in0.5ml/minUsing at flow rate can achieve better resolution.