Product Introduction: PM1621 and PM1621A x, gamma personal dosimeters are professional energy compensation instruments. These dosimeters monitor and measure the individual equivalent dose Hp (10) and individual dose equivalent rate Hp (10) emitted by x and γ. They have the ability to compensate for the functions between 10keV and 20MeV to ensure accurate measurement of these personal dosimeters. The characteristic of a radiation detector is that it allows users to monitor their personal radiation levels while staying away from photon radiation sources to prevent overexposure. The instrument room has high sensitivity and can store slight changes in natural environmental radiation.

Product Details

    Product Introduction

    PM1621And PM1621A x, γpersonal dosimeterIt is a professional energy compensation instrument. These dosimeters monitor and measure the individual equivalent dose Hp (10) and individual dose equivalent rate Hp (10) emitted by x and γ. They have the ability to compensate for the functions between 10keV and 20MeV to ensure accurate measurement of these personal dosimeters. The characteristic of a radiation detector is that it allows users to monitor their personal radiation levels while staying away from photon radiation sources to prevent overexposure. The instrument room has high sensitivity and can store slight changes in natural environmental radiation.

    Recommend experts or workers in environments with radiation resources or unknown radiation exposure to use PM1621/PM1621A

    In order to protect users from overexposure, the radiation detector has two warning thresholds. If any preset dose or dose rate exceeds the threshold, the dosimeter immediately alerts the user of danger through loud, audible sound. In case the radiation intensity exceeds the maximum upper limit for dose rate measurement, the dosimeter of the LCD display will display a warning sign "OL" and interrupt the sound alarm signal.

    Features

      1. Monitor and measure gamma and X-ray doses and dose rates over a wide energy range of up to 1Sv/h (100R/h);

    2. When the preset dose and/or dose rate threshold exceeds, sound an alarm to alert the user;

    3. The non-volatile memory records and stores 1000 sets of data;

    4. All recorded data is transmitted to a PC through an infrared channel for further processing and analysis.

    5. The sealed and shock resistant housing and fluorescent backlit LCD screen of the instrument allow for easy and accurate operation even in the harshest environments or unfavorable weather conditions.

    PM1621M/PM1621MA

    In addition to the previous features of PM1621/PM1621A, PM1621M/PM1621MA provides an additional built-in vibration alarm and utilizes Polimaster's proprietary advanced search algorithm to detect and locate radioactive materials. The instrument is a unique hybrid electronic dosimeter (ED) and a personal radiation detector (PRD) based device. PM1621M/MA is an ideal low-cost solution for law enforcement agencies and emergency personnel, allowing users to focus on urgent and immediate tasks while detectors continuously monitor radiation levels.

    Application field

      1. Network solutions

    2. Health Physics and Medicine

    3. Personal radiation protection

    4. Uranium mining and nuclear fuel production

    PM1621

    PM1621A

    PM1621M

    PM1621MA

    detector

    GM pipe

    GM pipe

    GM pipe

    GM pipe

    Dose rate display

    0.01μSv/h0.2Sv/h
    (1μR/h20R/h),Hp(10)

    0.01μSv/h2.0Sv/h
    (1μR/h200R/h),Hp(10)

    0.01μSv/h0.2Sv/h
    (1μR/h20R/h), Hp(10)

    0.01μSv/h2.0Sv/h
    (1μR/h200R/h),Hp(10)

    Dose rate accuracy

    ±(15+0.015/H+0.01H)%
    (0.1µSv/h0.1Sv/h,

    H-at mSv/h dose rate)

    ±(15+0.015/H+0.01H)%
    (0.1µSv/h1Sv/h,

    H-at mSv/h dose rate)

    ±(15+0,0015/H+0.01H)%
    (0.1µSv/h0.1Sv/h,
    H-at mSv/h dose rate)

    ±(15+0.015/H+0.01H)%
    (0.1µSv/h1Sv/h,
    H-at mSv/h dose rate)

    Dose measurement

    0.01 μSv9.99 Sv
    (1 μR999 R)

    0.01 μSv9.99 Sv
    (1 μR999 R)

    0.01 μSv9.99 Sv
    (1 μR999 R)

    0.01 μSv9.99 Sv
    (1 μR999 R)

    Measurement accuracy

    ±15%(1μSv9.99 Sv

    ±15%(1 μSv9.99Sv

    ±15% (1 μSv9.99 Sv

    ±15% (1 μSv9.99 Sv

    Energy Range

    10.0 KeV20.0 MeV

    10.0 Kev20.0 MeV

    10.0 KeV20.0 MeV

    10.0 KeV20.0 MeV

    relative to
    0.662MeV
    (137Cs)
    Energy response

    ±30%

    ±30%

    ±30%

    ±30%

    Within 5 minutes
    transient
    Maximum allowable
    Storage of gamma radiation:

    1 Sv/h
    (100 R/h)

    10 Sv/h
    (1000 R/h)

    1 Sv/h
    (100 R/h)

    10 Sv/h
    (1000 R/h)

    Compliant and qualified

    Meets the majority
    IEC 61526, and
    ANSI N42.20

    Meets the majority
    IEC 61526,
    and ANSI N42.20

    Meets the majority
    IEC 61526,and ANSI N42.20

    Meets the majority
    IEC 61526,and
    ANSI N42.20

    Alarm method:

    Visual, Audio

    Visual, Audio

    Visual, audio, vibration

    Visual, audio, vibration

    physical parameters

    size

    87x72x39 mm

    87x72x39 mm

    87x72x39 mm

    87x72x35 mm

    weight

    165g

    165g

    185g

    150g (5.3 oz)

    Environmental characteristics

    temperature

    -40+60 °C

    -40+60 °C

    -40+60 °C

    -40+60 °C

    humidity

    98% 95°F (35°C)

    98% 95°F (35°C)

    98% 40°C (104°F)

    98% 40°C (104°F)

    Protection level

    IP67

    IP67

    IP67

    IP67

    drop test

    0.7m (2.4 ft)

    0.7m (2.4 ft)

    0.7m (2.4 ft)

    0.7m (2.4 ft)

    抗水

    1m (up to 3.3 ft)

    1m (up to 3.3 ft)

    1m (up to 3.3 ft)

    1m (up to 3.3 ft)

    power supply

    battery

    One AA battery

    One AA battery

    One AA battery

    One AA battery

    battery life

    December

    December

    December

    December

    Battery discharge control

    LCD display

    LCD display

    LCD display

    LCD display

    Display critical
    exposure time

    yes

    yes

    yes

    yes

    PC
    transmission method

    Infrared data communication

    Infrared data communication

    Infrared data communication