IQ Sensor NetOnline multi parameter monitoring system
Single point multi parameter testing - a wise choice for modern sewage treatment plants
Single point multi parameter testing system182System(1to4Support sensors)

Can be connected1to4Support sensor, suitable for testing points/In situations where there are few testing parameters, such as a pool test4A different parameter. Multiple output signals to choose from, such asRS485, MODBUS, PROFIBUSor0/4-20mAAnalog current output
DIQ/S182Online multi parameter tester
When the test point or test parameter is less than or equal to4Or to test at a testing point1-4When considering parameters, priority can be given to them182System.
l1to4Support sensor
ldigital output
lCan accommodate allIQsensor
lZui is widely available for connection4branchIQsensor
lThe testing parameters are complete,pH/ORPTemperature, dissolved oxygen, conductivity, turbidity, suspended solids concentrationCOD/BOD/TOCAmmonia nitrogen, nitrate nitrogen, etc
lAll sensors are direct input type, with fast response
lCentralized power supply,100-240VACor24VDC
lDigital interface,MODBUS RTUorPROFIBUS DP
lZui Duo5Group simulation current output and6Group relay output
DIQ/S182Performance characteristics of online multi parameter tester:
model |
DIQ/S 182 |
DIQ/S 182 XT |
DIQ/S182 XT-4 |
|
|
|
|
The largest number of sensors |
2 |
2 |
4 |
analog output |
2Group simulation current(0/4-20 mA) 3Group relay |
4Group simulation current(0/4-20 mA) 5Group relay |
5Group simulation current(0/4-20 mA) 6Group relay |
|
digital output PROFIBUS |
DIQ/S 182-PR 3Group relay |
none |
DIQ/S 182 XT-4-PR 3Group relay |
|
digital output MODBUS |
DIQ/S 182-MOD 3Group relay |
none |
DIQ/S 182 XT-4-MOD 3Group relay |
screen display |
Sensor connection and system expansion |
extension module |
|
|
|
|
lCan display two sets of test values simultaneously lCan display the status of output signals |
lauto-confirmationIQSensor and display lCan be connected again1A power module lCan be stacked to form a stack lDistance reachable250rice |
lDIQ/JB: Connect again1branchIQSensors or extended testing points lDIQ/CHVElectromagnetic valve module, automatic cleaning system |
DIQ/S182configuration scheme
example1 |
example2 |
example3 |
|
Model and item number DIQ/S 182 472000 SACIQ-7.0 IQSensor user selection |
Model and item number DIQ/S 182 XT 472001 2XSACIQ-7.0 480042 2branchIQSensor user selection |
Model and item number DIQ/S 182 XT-4 472000 4XSACIQ-7.0 480042 DIQ/JB 472005 4branchIQSensor user selection |
Single channel |
dual-channel | 4通道 |
|
Single test point with analog output
|
Single test point with digital output |
|
Model number Item Number DIQ/S 182 XT-4 472015 3XSACIQ-7.0 480042 VARiON®Plus700 IQ 107066 another2branchIQSensor user selection |
Model number Item Number DIQ/S 182 XT-4-PR 472017 4XSACIQ-7.0 480042 4branchIQSensors User selection |
Analog current output |
Digital signal output |
DIQ/S182Technical Specifications
IQModule List | |||||
goodsnumber |
model |
Functional Description |
power consumption(W) |
IQinterface |
|
1、 Main controller182system | |||||
472000 |
DIQ/S 182 |
182Monitor, can be connected2Support sensor, with2Group module current(0/4-20mA)output sum3Group relay output |
12 |
1 |
|
472001 |
DIQ/S 182 XT |
182Monitor, can be connected2Support sensor, with4Group module current output(0/4-20mA)and5Group relay output |
12 |
3 |
|
472002 |
DIQ/S 182-PR |
182Monitor, can be connected2Support sensor, with3Group relay andPROFIBUS-DPoutput |
12 |
2 |
|
472003 |
DIQ/S 182-MOD |
182Monitor, can be connected2Support sensor, with3Group relay andMODBUS RTU/RS 485output |
12 |
2 |
|
472010 |
DIQ/S 182/24V |
182Monitor, can be connected2Support sensor, with2Group module current(0/4-20mA)output sum3Group relay output |
12 |
1 |
|
472011 |
DIQ/S 182 XT/24V |
182Monitor, can be connected2Support sensor, with4Group module current output(0/4-20mA)and5Group relay output,24Vpower supply |
12 |
3 |
|
472012 |
DIQ/S 182-PR/24V |
182Monitor, can be connected2Support sensor, with3Group relay andPROFIBUS-DPoutput24Vpower supply |
12 |
2 |
|
472013 |
DIQ/S 182-MOD/24V |
182Monitor, can be connected2Support sensor, with3Group relay andMODBUS RTU/RS 485output24Vpower supply |
12 |
2 |
|
472015 |
DIQ/S 182 XT-4 |
182Monitor, can be connected4Support sensor, with5Group module current output(0/4-20mA)and6Group relay output |
12 |
3 |
|
472017 |
DIQ/S 182 XT-4-PR |
182Monitor, can be connected4Support sensor, with3Group relay andPROFIBUS-DPoutput |
12 |
6 |
|
472019 |
DIQ/S 182 XT-4-MOD |
182Monitor, can be connected4Support sensor, with3Group relay andMODBUS RTU/RS 485output24Vpower supply |
12 |
6 |
|
472021 |
DIQ/S 182 XT-4/24V |
182Monitor, can be connected4Support sensor, with5Group module current output(0/4-20mA)and6Group relay output,24Vpower supply |
12 |
3 |
|
472023 |
DIQ/S 182 XT-4-PR/24V |
182Monitor, can be connected4Support sensor, with3Group relay andPROFIBUS-DPoutput24Vpower supply |
12 |
6 |
|
472024 |
DIQ/S 182 XT-4-MOD/24V |
182Monitor, can be connected4Support sensor, with3Group relay andMODBUS RTU/RS 485output24Vpower supply |
12 |
6 |
|
Note: All182The power generated by the system is16.5WThe power consumed by oneself is12WSo the rest is available for othersIQThe power used by the component is4.5W. | |||||
471000 |
MIQ/MC |
MIQController, standard software terminal, can be operated on a computer |
1.5 |
0 |
|
471001 |
MIQ/MC-RS |
MIQController, standard software terminal, can be operated on a computer, withRS232interface |
1.5 |
0 |
|
471002 |
MIQ/MC-PR |
MIQController, standard software terminal, can be operated on a computer, withPROFIBUS-DPinterface |
3 |
0 |
|
471003 |
MIQ/MC-MOD |
MIQController, standard software terminal, can be operated on a computer, withMODBUS RTU/RS485interface |
3 |
0 |
|
471010 |
MIQ/MC-A |
MIQController, standard software terminal, can be operated on a computer, with automatic air pressure compensation function |
1.5 |
0 |
|
471011 |
MIQ/MC-A-RS |
MIQController, standard software terminal, can be operated on a computer, with automatic air pressure compensation function, equipped withRS232interface |
1.5 |
0 |
|
471012 |
MIQ/MC-A-PR |
MIQController, standard software terminal, can be operated on a computer, with automatic air pressure compensation function, equipped withPROFIBUS-DPinterface |
3 |
0 |
|
471013 |
MIQ/MC-A-MOD |
MIQController, standard software terminal, can be operated on a computer, with automatic air pressure compensation function, equipped withMODBUS RTU/RS485interface |
3 |
0 |
|
3、 Power module | |||||
480004 |
MIQ/PS |
Power module, capable of outputting18WThe power,100-240VAC |
+18 |
3 |
|
480006 |
MIQ/24V |
Power module, capable of outputting18WThe power,24VAC/VDC |
+18 |
3 |
|
480021 |
MIQ/Blue PS SET |
Wireless transmission module, when connected100-240VACWhen using alternating current, it can output7WThe power, when connected24VWhen using direct current, it can output24WThe power itself needs to be consumed0.6WThe power of |
0.6 |
3 |
|
4、 Expansion wiring module | |||||
480008 |
MIQ/JB |
Expansion wiring module, used to expand test points |
0.0 |
4 |
|
480010 |
MIQ/JBR |
Expansion wiring module, built-in preamplifier, capable of retransmitting1000Rice, used to expand testing points |
0.2 |
4 |
|
472005 |
DIQ/JB |
182Supporting expansion wiring module, capable of connecting2branchIQsensor |
0.0 |
0 |
|
5、 Output module | |||||
480013 |
MIQ/R6 |
Relay output module,6Group relay output |
1.5 |
2 |
|
480014 |
MIQ/CR3 |
Output module,3Group relay output, threeGroup module current output |
3 |
2 |
|
480015 |
MIQ/C6 |
Current output module,6Group simulation current output |
3 |
2 |
|
480016 |
MIQ/IC2 |
Current input module,2Group current input |
0.2 |
2 |
|
480020 |
MIQ/IF232 |
232interface module |
0.2 |
2 |
|
470004 |
MIQ/PR |
PROFIBUSoutput module |
3 |
2 |
|
470006 |
MIQ/MOD |
MODBUSoutput module |
3 |
2 |
|
470008 |
MIQ/A |
Automatic pressure compensation module(Dissolved oxygen test) |
1.5 |
4 |
|
470011 |
MIQ/A-PR |
Automatic pressure compensation module(Dissolved oxygen test), withPROFIBUSoutput |
3 |
2 |
|
470012 |
MIQ/A-MOD |
Automatic pressure compensation module(Dissolved oxygen test), withMODBUSoutput |
3 |
2 |
|
6、 Cleaning module | |||||
480018 |
MIQ/CHV PLUS |
Valve driven module, used for automatic air blowing |
1.0 |
1 |
|
472007 |
DIQ/CHV |
182Valve driven module, used for automatic air blowing |
0.8 |
0 |
|