Ohhaus conductivity electrode STCON3 |
ohausSTThe series of electrodes includesPHThis article introduces various factors such as ion concentration, conductivity, dissolved oxygen, etcSTCON3The electrode is a conductivity electrode, suitable for all models of Ohhaus conductivity meters
|
STCON3The four ring conductive electrode adopts a four ring potential Designed based on principles. Due to the resolution2chip Polarization issues in electrodes, the four ring electrode can Accurate over a larger range of measurementMeasurement.The built-in temperature sensor makes the electrical conductivityextremeIt has automatic temperature compensation function.
Standard conductive fluid: ●1413µS/cmStandard liquid ●12.88mS/cmStandard liquid |
|
Ohhaus conductivity electrode STCON3Technical Specifications
electrode type |
conductivity electrode |
measurement range |
2 µS/cm – 200 mS/cm; 0 – 50 °C |
cable |
1.1 m |
Electrode rod material |
plastic |
size |
15 mm |
Conductivity measurement range |
2 µS/cm – 200 mS/cm |
Measurement range (temperature) |
0 °C – 50 °C |
Net weight |
85 g |
temperature range |
0 °C – 50 °C |
temperature sensor |
30 kΩ |
working environment |
10 ° C-40 ° C, 85% RH, non condensing |
Conductivity electrode STCON3 optional standard solution
Standard solution conductivity 10 µ s/cm 250ml |
|
Standard liquid conductivity 84 µ s/cm 250ml |
|
Standard liquid conductivity 1413 µ s/cm 250ml |
|
Standard liquid conductivity 12.88ms/cm 250ml |
STCON3Conductivity Electrode Operation Guide
During the measurement process, the plastic sleeve must be tightly fitted onto the electrode main rod.
2. The liquid level during measurement must not be lower than the scale line on the electrode sleeve.
3. During the transition from high conductivity measurement to low conductivity measurement, special attention should be paid to cleaning the electrodes to prevent measurement deviation.
4. Pay attention to observation and ensure that there are no bubbles in the measuring pool. It is recommended to insert the electrode into the solution at a certain angle and then vertically to avoid the occurrence of bubbles.
When measuring at different temperatures, it is necessary to wait for the instrument to stabilize the sample temperature display before proceeding. In this case, it is recommended to use manual endpoint judgment.
Samples below 6.70 µ S/cm are not recommended to use this electrode.
During and after the measurement process, clean the electrodes with distilled water.
8. For calibration and measurement steps, refer to the corresponding conductivity meter manual.
Ohhaus conductivity electrode STCON3Precautions
Do not remove the sleeve during the measurement process.
2. This electrode should not be used for measuring organic solvents, nor should it be cleaned with organic solvents.
3. It should not be used in environments beyond the temperature range of 0-50 ° C.
4. The measurement performance of the electrode can only be ensured when used together with the accompanying conductivity meter.
Recommended instruments: Ohhaus conductivity meter ST300C, Ohhaus ST3100C conductivity meter, etc. For more water quality testing instruments, please feel free to inquire with sales personnel.
After sales service commitment |
1. All products are covered by a one-year warranty from the date of sale, except for consumables, in the event of non-human damage.
During the warranty period, if there are any malfunctions or component damages caused by quality issues, our company will be responsible for repairing them.
3. If there are quality problems outside the warranty period, or if the instrument components are damaged due to usage or other human factors, our company will only charge the cost of the replaced components.
4. Our company provides 24-hour free consultation and maintenance services, with a response time of 4 hours. If the maintenance personnel cannot troubleshoot the product through telephone communication, the buyer will send the product back for maintenance, and our company will be responsible for the postage incurred.