National standard for desulfurization gypsum crystal water analyzer in power plants (working principle)

NegotiableUpdate on 03/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Shenzhen Guanya brand CS-002GL power plant desulfurization gypsum crystal water analyzer (working principle) is a multi-functional gypsum moisture analyzer that can quickly detect the content of gypsum attached water and crystal water, as well as quickly determine the three-phase indicators of gypsum. The gypsum three-phase analysis and detection instrument meets the requirements for moisture content detection in each stage of enterprise processing, quickly determining the composition of each gypsum phase in building gypsum, mainly measuring the content of adsorbed water, soluble anhydrous gypsum, hemihydrate gypsum, and dihydrate gypsum in building gypsum.

Product Details

Shenzhen Guanya brand CS-002GL power plantCrystal water analyzer for desulfurization gypsumThe national standard (working principle) is a multifunctional gypsum moisture meter that can quickly detect the content of gypsum attached water and crystal water, as well as quickly determine the three-phase indicators of gypsum. The gypsum three-phase analysis and detection instrument meets the requirements for moisture content detection in each stage of enterprise processing, quickly determining the composition of each gypsum phase in building gypsum, mainly measuring the content of adsorbed water, soluble anhydrous gypsum, hemihydrate gypsum, and dihydrate gypsum in building gypsum.

The significance of three-phase detection of gypsum powder:

The phase composition analysis of gypsum: Raw gypsum is calcined to become gypsum (building gypsum). Due to changes in process parameters during calcination, there are significant differences in the content of hemihydrate gypsum, anhydrous gypsum, and dihydrate gypsum in gypsum. This difference is reflected in the impact on the quality of building gypsum, such as the standard consistency, setting time, tensile strength, and other indicators of building gypsum. Gypsum powder equipment is affected by the content of various dehydrated phases in building gypsum. In order to adjust process parameters in a timely manner and achieve stable and high production, a rapid method for determining the composition of dehydrated phases in building gypsum is needed, so as to adjust production process parameters in a timely manner based on the measurement results. The traditional three item analysis requires checking the attached water and crystal water of gypsum first, and then using other methods (differential scanning calorimetry) for gypsum phase composition analysis. This method requires selecting reference samples, and the calculation process is relatively complex and time-consuming. The CS-002GL gypsum powder phase composition analyzer produced by Shenzhen Guanya Technology Co., Ltd. can quickly detect the attached water and crystal water of gypsum powder. Combined with the improved desulfurization building gypsum phase composition analysis method, it greatly shortens the test time and is beneficial for manufacturers to control and improve product quality.

The necessity of detecting water and crystal water attached to gypsum powder

The moisture detection of gypsum mainly detects attached water (also known as free water, free water) and crystal water. From an application perspective, if the attached moisture content is too high, it will cause inconvenience for storage and transportation. At the same time, such a high moisture content will also cause inconvenience for applications such as cement retarders and gypsum building materials. Application units must undergo secondary treatment before use, and attached water should be strengthened for control. The various properties of desulfurized building gypsum are related to the proportion of its internal hemihydrate gypsum, soluble anhydrous gypsum, and residual dihydrate gypsum, such as the setting time, which is largely affected by the content of residual dihydrate gypsum in desulfurized gypsum. It can be affirmed that both crystalline water and attached water need to be tested for the gypsum industry.GuanyacardCS-002GLplaster powderPhase analysis analyzerThe seven inch LCD touch screen moisture meter used provides a clear view of high-definition LCD screen data. This instrument is specially developed for the gypsum powder industry and can test gypsum powder adhesion water, crystal water, taste, and gypsum three-phase with one click.

Product Name: CS-002GL Gypsum Phase Analyzer (Model)

Brand: Guanya Technology

Manufacturer: Shenzhen Guanya Technology Co., Ltd

Application of Guanya brand gypsum powder phase composition analyzer:

The Guanya brand CS-002GL gypsum phase analyzer can be widely used for rapid detection of moisture in raw materials, semi-finished products, and finished products such as anhydrous gypsum, titanium gypsum, high-strength gypsum, gypsum, dihydrate gypsum, *, phosphogypsum, desulfurization gypsum, anhydrous gypsum, natural gypsum, building gypsum, gypsum board, fiber gypsum, plastering gypsum, burnt gypsum, food gypsum, pharmaceutical gypsum, putty powder, gypsum raw materials, raw gypsum powder, redstone paste powder, etc., as well as three-phase analysis of various types of gypsum.

The product meets the standards:

GB/T 29249-2012 Electronic Weighing Drying Method Moisture Determination Instrument

GB/T 5484-2000 Methods for Chemical Analysis of Gypsum

GB/T17669 12-1999 Determination of Crystalline Water Content in Building Gypsum

FHZDZFJSK0101 Determination of Crystalline Water in Non metallic Gypsum by Mass Method

GBT 37785-2019 flue gas desulfurization gypsum

JC/T 2074-2011 flue gas desulfurization gypsum

JC/T 2038-2010 α - type high-strength gypsum

GBT36141-2018 Analysis Method for Phase Composition of Building Gypsum

Guanya brand CS-002GL gypsum powder phase composition analyzer product introduction

GuanyacardCS-002GLplaster powderPhase analysis analyzerIt is a new type of testing equipment developed for the gypsum powder industry. The principle of this instrument complies with the national standard GB/T 5484-2000 Gypsum Chemical Analysis Method; GB/T17669 1.2.1999 Determination of Crystalline Water Content in Building Gypsum; Quality method for determination of crystallization water in non-metallic mineral gypsum; GB/T 5484-2000 "Methods for Chemical Analysis of Gypsum"; GB_T36141-2018 "Analysis Method for Phase Composition of Building Gypsum".

The Shenzhen Guanya brand CS-002GL halogen moisture detector is a multifunctional gypsum moisture meter that can quickly detect the content of gypsum attached water and crystal water, as well as quickly determine the three-phase indicators of gypsum. The gypsum three-phase analysis and detection instrument meets the requirements for moisture content detection in every stage of enterprise processing, quickly determining the composition of each gypsum phase in building gypsum. It mainly measures the content of adsorbed water, soluble anhydrous gypsum, hemihydrate gypsum, and dihydrate gypsum in building gypsum, and calculates the purity of gypsum through indicators. The results obtained by the gypsum three-phase analysis and detection instrument are consistent with the national standard GB/T5484-2000 gypsum chemical analysis method, which greatly improves the detection efficiency.

Through extensive comparative experiments, the results of the Guanya gypsum powder phase analyzer are consistent with the national standards GB/T 5484-2000 "Methods for Chemical Analysis of Gypsum" and GB_T36141-2018 "Methods for Phase Composition Analysis of Building Gypsum", greatly improving detection efficiency. Generally, samples can quickly and accurately detect the three-phase values (anhydrous AIII, hemihydrate HH, dihydrate DH), grade (purity), attached water, crystalline water, hydration C2, and dihydrate heating quality change d2 of gypsum. The product is widely used for rapid detection of attached water and crystalline water in raw materials, powders, particles, semi-finished products, finished products, etc., targeting non-metallic minerals, building gypsum, desulfurization gypsum, phosphogypsum, natural gypsum, industrial by-product gypsum, gypsum mortar, etc. Samples such as fly ash, coal, and mineral powder can provide accurate moisture detection solutions.

power plantCrystal water analyzer for desulfurization gypsumNational standard (working principle)