Motor vehicle headlight detector

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Gasboard-6100

Product Details

Product Features
    • The optical system can quickly and accurately detect various parameters of various types of headlights
    • The instrument comes with a large LCD display, making it easier to adjust the lights
    • The instrument has automatic discrimination technology, which can eliminate external light interference, and has high accuracy in automatic light tracking and positioning
    • The detector is equipped with a high-performance embedded processor for data acquisition and analysis
    • Equipped with powerful software functions, instrument operation, calibration, and fault self checking are simpler and more convenient
    • Can be quickly disassembled and assembled, easy to move, easy to operate, and accurately measured
    • Provide rich and reliable communication protocols to facilitate the original detection system's requirements for replacing the light meter
Technical Specifications

measurement range indication error
luminous intensity (0~120000)cd When the optical axis offset value (angle) is zero, the indication error is ≤± 10% (relative error)
When the optical axis offset value (angle) is at any value within the verification range, the indication error is ≤± 12%
Offset of high beam optical axis Vertical direction: 2 ° 30 ′ up to 3 ° down
Horizontal direction: 3 ° left to 3 ° right
Indication error: not greater than ± 3.2cm/dam (± 10 ′)
Difference between readings: not greater than ± 3.2cm/dam (± 10 ′)
Deviation of low beam optical axis Vertical direction: 2 ° 30 ′ up to 3 ° down
Horizontal direction: 3 ° left to 3 ° right
Indication error: not greater than ± 3.2cm/dam (± 10 ′)
Lamp height (350~1400) mm Indication error: not greater than ± 10mm
ambient temperature (-10~40)℃
working power supply 100~240VAC,250W
Overall dimensions 800×670×1700(mm)
Instrument weight About 100 kg