Mask sealing tester

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The quantitative fit test of coordinated movements can be used as a method to select a mask that fits one's own face. In the tightness testing mode, follow the pre-set actions, measure in sequence, and display the test results of each action and the comprehensive measurement results of all actions.

Product Details

Definition:

A device that measures the dust concentration on the outside and inside of the mask separately, and calculates the intrusion rate (leakage rate%) of dust inside the mask based on the results. The experimental particles use general dust suspended indoors. When measuring the dust on the inside of a mask, a test guide or tube fitting kit should be used.

Scope of application:

There is no other tightness tester that can quantitatively test the tightness of all types of respirators. This tightness tester can perform tightness testing on gas masks, SCBAs respirators, and other types of respirators.

Research on the Inspection, Training, and Teaching of Mask and Face Mask Tightness

Performance evaluation of respiratory protective masks (PAPR)

Self contained breathing apparatus tightness test

Gas mask tightness test

Feature:

1. Use one detector (particle counter) to automatically switch and continuously measure the number of particles indoors (outside the mask) and inside the mask. This can reduce errors caused by differences in detector characteristics.

2. Provide three modes: tightness testing mode, tightness inspection mode, and practice mode, which can be distinguished and used according to various purposes.

3. The test guide can be used separately for measurement (without damaging the mask) or the tube joint kit can be used for measurement (with holes drilled on the mask).

4. Equipped with a heating tube to prevent condensation of water vapor during exhalation and the formation of water droplets.

5. Comes with RS-232C output function for outputting measurement data.

6. The wearing condition of the mask can be confirmed through a mirror.

Product Features:

1. Easy to operate and convenient to use

2. Independent operation type - no need for external computer connection

3. Optional mask sampling adapter allows for tightness testing of various masks

4. Color touch screen can be operated with fingers or a pen

5. FitPro+TM fit testing software can automatically complete the test

6. External computer can generate reports and print tightness test cards

7. The tightness coefficient is greater than 10000

8. Calculating the sealing factor of masks using microscopic particles in ambient air

9. Provide interactive training tools for initial and subsequent training

Technical Specifications:

Test object: Evaluation of the tightness between masks and faces

Measurement items: particle count and leakage rate, protection factor

Measurement principle: Particle number concentration based on laser scattering method (determination of particle number ratio of indoor dust and dust inside masks)

Object particle size: Choose from 0.3 μ m or more, 0.5 μ m or more, and 0.3 to 0.5 μ m

Measurement range: Counting range: 0-999999 Count, Leakage rate: 0-100%, Protection factor: 1-10000

Measurement accuracy: 5% (when the particle number concentration is 100000/L)

Measurement time: The standard measurement time is to purify the outside and inside of the mask for 10 seconds each, and measure for 3 seconds each (totaling approximately 26 seconds)

Suction flow rate: 1 L/min

Internal functions: leakage rate and protection coefficient calculation function, heating tube temperature adjustment function, drying function, RS-232C output function

Usage environment: 0-40 ℃, 30-90% RH (non condensing)

Main protective device: Fuse tube (for AC250V, with a diameter of 5.2 × 20 mm, 3.15A)

Power supply: AC100~240V, 50/60Hz, approximately 0.5 A

Main body size and mass: 210 (W) × 240 (D) × 232 (H) mm (excluding protrusions), approximately 3 kg

Technical features:

1. Easy to operate and convenient to use;

2. Independent operation type, no need for external computer connection;

3. Optional mask sampling adapter, allowing for tightness testing of various masks;

4. Color touch screens can be operated with fingers or a pen;

5. FitPro+TM fit testing software can automatically complete the test;

6. External computer can generate reports and print tightness test cards;

7. Calculate the sealing factor of a mask using microscopic particles in the ambient air;

8. Provide interactive training tools for initial and subsequent training.