E-mail
1311327132@qq.com
-
Phone
18037316198
-
Address
No. 20 Bosong Road, Jinshui District, Zhengzhou City
Zhengzhou Ansheng Scientific Instrument Co., Ltd
1311327132@qq.com
18037316198
No. 20 Bosong Road, Jinshui District, Zhengzhou City
Lhasa Box type Resistance Furnace (Ceramic Full Fiber)Specification parameters:
model |
AS-1400 |
Temperature parameters |
1400℃ |
Voltage AC |
220V/380V |
rated temperature |
1400℃ |
Long term working temperature |
1350℃ |
Uniformity of temperature field inside the furnace |
±5℃ (depending on the size of the heating chamber) |
Temperature measuring components and temperature measuring range |
Platinum rhodium platinum S temperature measurement range 0-1700 ℃ |
Program curve segment |
30 paragraphs |
heating rate |
1 ℃/h-40 ℃/min, recommended 20 ℃/min |
Heating element |
Elema |
Thermal insulation material |
Imported high-purity alumina fiberboard |
Cooling method |
Double layered furnace shell, air-cooled |
Furnace body temperature |
≤ 50 degrees |
Warranty scope and duration |
The electric furnace comes with a one-year free warranty, and the heating element is not covered by the warranty (natural damage within three months can be replaced free of charge) |
Customer selection |
1. Crucible, box bowl, corundum furnace pad/silicon carbide pad 2. RS485 communication, computer control software and hardware 3. Touch screen controlled temperature controller 4. Paperless recorder 5. Increase exhaust ports 6. Consumables: Heating elements, temperature measuring components 7. Increase observation ports and endoscopes |
Furnace specifications:
specifications |
Furnace dimensions (depth, width, height mm) |
voltage |
Power kw |
PID instrumentControl accuracy |
A |
100x100x100 |
220 |
1 |
±1 |
B |
150X100X100 |
220 |
1.5 |
±1 |
C |
200X150X150 |
220 |
2 |
±1 |
D |
300X200X120 |
220 |
4 |
±1 |
E |
200×200×200 |
220 |
6 |
±1 |
F |
300×200×200 |
220 |
8 |
±1 |
G |
300X250X250 |
220/380 |
8 |
±1 |
H |
300×300×300 |
220/380 |
10 |
±1 |
I |
400X250X160 |
220/380 |
8 |
±1 |
J |
400×300×300 |
220/380 |
12 |
±1 |
K |
500×300×200 |
220/380 |
15 |
±1 |
L |
500×300×300 |
380 |
18 |
±1 |
M |
500X400X400 |
380 |
20 |
±1 |
N |
500×500×500 |
380 |
25 |
±1 |
U |
800×500×500 |
380 |
40 |
±1 |
V |
1200×500×500 |
380 |
85 |
±1 |
W |
1200×800×800 |
380 |
110 |
±1 |
Lhasa Box type Resistance Furnace (Ceramic Full Fiber)Special furnace dimensions can be customized according to customer requirements!
Reasons and solutions for temperature control faults in ceramic muffle furnaces
The temperature display value is relatively low
reason:
1. The reference temperature of the thermocouple is too high;
2. Thermocouple grid leakage;
3. Thermocouple gate degeneration;
4. The measurement position of thermocouples is too far away;
5. Compensate for the mismatch between wires and thermocouples;
6. Compensate for the reverse connection between the wire and the thermoelectric dipole;
7. Compensate for the increase in wire insulation;
Solution:
1. Review the reference temperature and ensure it matches the request;
2. Review the gate and report connection;
3. Replace the thermocouple;
4. Mobilize measurement status;
5. Replace the compensating wire;
6. Accurately connect and compensate for the wires;
7. Replace the compensating wire;