Product Overview:
HY-8Large capacity oscillatorIt is a biochemical instrument for cultivating and preparing biological samples. It uses a double-layer stainless steel spring mesh fixture device to fix solutions such as test tubes, beakers, and triangular flasks for analysis. The permanent magnet DC motor it uses, coupled with a relatively advanced speed control circuit, has the characteristics of low operating noise, high speed balance accuracy, wide speed range, and low losses. It is a laboratory equipment for research, education, and production departments such as plants, biology, microbiology, biological products, genetics, viruses, medicine, and environmental protection The instrument is floor standing, with a low center of gravity, and operates smoothly and reliably in continuous reciprocating oscillation.
Technical parameters of HY-8 high-capacity oscillator:
1. Power supply voltage: 220V ± 10% 50Hz ± Hz
2. Oscillation amplitude: 20mm
3. Oscillation frequency: starting -260 times/minute
4. Timing range: 0-120 minutes
5. Working method: Horizontal rotation
6. Mesh clamp size: 700 × 620mm
7. Bottled quantity: 250ml x 56, 500ml x 30 triangular flasks
8. Dimensions: 700 × 620 × 280mm
9. Whole machine power: 100W
Note 1: Type A is a digital speed measurement type that can accurately understand the real-time operating frequency.
Note 2: Special specifications and requirements can be customized
Maintenance and upkeep:
1. Proper use of instruments and keeping them in good working condition can prolong their lifespan.
2. The bearings of the oscillator transmission part have been filled with an appropriate amount of lubricating grease No. 1 calcium sodium base before leaving the factory. During continuous operation of the instrument, lubricating grease should be added every six months, with a filling amount of about one-third of the bearing space.
3. During continuous operation, the instrument should be regularly inspected every three months to check for any water droplets, dirt, or other debris falling onto the motor and control components; Check fuses, control components, and fastening screws.
4. Natural wear and tear of the instrument after use is a normal phenomenon. After one year of use, if abnormal noise is found in the motor, abnormal heating system, worn bearings in the transmission part, loose or cracked belts, abnormal heating constant temperature, or failure of electronic control components, our company will continue to provide high-quality services and assist in handling these faults.